Functional analysis of Fontan energy dissipation

被引:58
作者
Dasi, Lakshmi P. [1 ]
Pekkan, Kerem [2 ]
Katajima, Hiroumi D. [1 ]
Yoganathan, Ajit P. [1 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Sch Biomed Engn, Atlanta, GA 30332 USA
[2] Carnegie Mellon Univ, Dept Biomed & Mech Engn, Pittsburgh, PA 15213 USA
关键词
Fontan; powerless; energy dissipation; head loss; total cavopulmonary connection; vessel junction;
D O I
10.1016/j.jbiomech.2008.04.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We formalize the hydrodynamic energy dissipation in the total cavopulmonary connection (TCPC) using dimensional analysis and examine the effect of governing flow variables: namely, cardiac output, flow split, body surface area, Reynolds number, and certain geometric characteristics. A simplistic and clinically useful mathematical model of the dependence of energy dissipation on the governing variables is developed. Ill vitro energy loss data corresponding to six patients' anatomics validated the predicted dependency of each variable and Was Used to develop a predictive, semi-empirical energy dissipation model of the TCPC. It is shown that energy dissipation is a cubic function of pulmonary flow split in the physiological range. Furthermore, non-dimensional energy dissipation. which is a measure of resistance of the connection, is dependent on Reynolds number and geometrical factors alone. Non-dimensional energy dissipation decreases with Reynolds number as Re-0.25 (R-2 > 0.95). In addition. for high Reynolds numbers, within physiological exercise limits, dissipation strongly correlates to minimum PA area as a power law decay with an exponent of -5/4 (R-2 > 0.88). This study presents a simple analytical form of energy dissipation rate in complex patient-specific TCPCs that accurately captures the effect of cardiac output, flow split, body surface area, Reynolds number, and pulmonary artery size within physiological limits. Further Studies with larger sample sizes are necessary for incorporating finer geometrical parameters such as vessel curvatures and offsets. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2246 / 2252
页数:7
相关论文
共 21 条
  • [1] Blasius H, 1911, PHYS Z, V12, P1175
  • [2] On physically similar systems, illustrations of the use of dimensional equations
    Buckingham, E
    [J]. PHYSICAL REVIEW, 1914, 4 (04): : 345 - 376
  • [3] Single-step stereolithography of complex anatomical models for optical flow measurements
    de Zélicourt, D
    Pekkan, K
    Kitajima, H
    Frakes, D
    Yoganathan, AP
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2005, 127 (01): : 204 - 207
  • [4] In vitro flow analysis of a patient-specific intraatrial total cavopulmonary connection
    de Zélicourt, DA
    Pekkan, K
    Wills, L
    Kanter, K
    Forbess, J
    Sharma, S
    Fogel, M
    Yoganathan, AP
    [J]. ANNALS OF THORACIC SURGERY, 2005, 79 (06) : 2094 - 2102
  • [5] DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
  • [6] Toward designing the optimal total cavopulmonary connection: An in vitro study
    Ensley, AE
    Lynch, P
    Chatzimavroudis, GP
    Lucas, C
    Sharma, S
    Yoganathan, AP
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (04) : 1384 - 1390
  • [7] SURGICAL REPAIR OF TRICUSPID ATRESIA
    FONTAN, F
    BAUDET, E
    [J]. THORAX, 1971, 26 (03) : 240 - +
  • [8] Power dissipation associated with surgical operations' hemodynamics: Critical issues and application to the total cavopulmonary connection
    Grigioni, M
    D'Avenio, G
    Amodeo, A
    Di Donato, RM
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (09) : 1583 - 1594
  • [9] HOSEIN RBM, 2007, 2 COMMANDMENTS, V12, P344
  • [10] KITAJIMA HD, 2007, IN VITRO FLUID DYNAM