Tissue-Specific Sparse Deconvolution for Low-Dose CT Perfusion

被引:0
作者
Fang, Ruogu [1 ]
Chen, Tsuhan [1 ]
Sanelli, Pina C. [2 ,3 ]
机构
[1] Cornell Univ, Dept Elect & Comp Engn, Ithaca, NY 14850 USA
[2] Weill Cornell Med Coll, Dept Radiol, New York, NY 10065 USA
[3] Weill Cornell Med Coll, Dept Publ Hlth, New York, NY 10065 USA
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION (MICCAI 2013), PT I | 2013年 / 8149卷
关键词
IMAGES; BRAIN;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Sparse perfusion deconvolution has been recently proposed to effectively improve the image quality and diagnostic accuracy of low-dose perfusion CT by extracting the complementary information from the high-dose perfusion maps to restore the low-dose using a joint spatio-temporal model. However the low-contrast tissue classes where infarct core and ischemic penumbra usually occur in cerebral perfusion CT tend to be over-smoothed, leading to loss of essential biomarkers. In this paper, we extend this line of work by introducing tissue-specific sparse deconvolution to preserve the subtle perfusion information in the low-contrast tissue classes by learning tissue-specific dictionaries for each tissue class, and restore the low-dose perfusion maps by joining the tissue segments reconstructed from the corresponding dictionaries. Extensive validation on clinical datasets of patients with cerebrovascular disease demonstrates the superior performance of our proposed method with the advantage of better differentiation between abnormal and normal tissue in these patients.
引用
收藏
页码:114 / 121
页数:8
相关论文
共 13 条
  • [1] Addition of computer simulated noise to investigate radiation dose and image quality in images with spatial correlation of statistical noise: an example application to X-ray CT of the brain
    Britten, AJ
    Crotty, M
    Kiremidjian, H
    Grundy, A
    Adam, EJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (916) : 323 - 328
  • [2] Quantification of bolus-tracking MRI: Improved characterization of the tissue residue function using Tikhonov regularization
    Calamante, F
    Gadian, DG
    Connelly, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (06) : 1237 - 1247
  • [3] Fang R., 2013, Medical image analysis
  • [4] Fang RG, 2012, LECT NOTES COMPUT SC, V7510, P272, DOI 10.1007/978-3-642-33415-3_34
  • [5] A Spatio-Temporal Deconvolution Method to Improve Perfusion CT Quantification
    He, Lili
    Orten, Burkay
    Do, Synho
    Karl, W. Clem
    Kambadakone, Avinish
    Sahani, Dushyant V.
    Pien, Homer
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (05) : 1182 - 1191
  • [6] Cerebral perfusion CT: Technique and clinical applications
    Hoeffner, EG
    Case, I
    Jain, R
    Gujar, SK
    Shah, GV
    Deveikis, JP
    Carlos, RC
    Thompson, BG
    Harrigan, MR
    Mukherji, SK
    [J]. RADIOLOGY, 2004, 231 (03) : 632 - 644
  • [7] Mairal J., 2009, P 26 ANN INT C MACH, P689
  • [8] Perfusion CT: a worthwhile enhancement?
    Miles, KA
    Griffiths, MR
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (904) : 220 - 231
  • [9] Automated model-based tissue classification of MR images of the brain
    Van Leemput, K
    Maes, F
    Vandermeulen, D
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (10) : 897 - 908
  • [10] FDA Investigates the Safety of Brain Perfusion CT
    Wintermark, M.
    Lev, M. H.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2010, 31 (01) : 2 - 3