Extension of the crosstalk cancellation method in ultrasonic transducer arrays from the harmonic regime to the transient one

被引:2
|
作者
Bybi, A. [1 ]
Grondel, S. [1 ]
Assaad, J. [1 ]
Hladky-Hennion, A. -C. [2 ]
机构
[1] Univ Valenciennes & Hainaut Cambresis, Dept OAE, CNRS, IEMN,UMR 8520, F-59313 Valenciennes 9, France
[2] CNRS, Dept ISEN, UMR 8520, IEMN, F-59046 Lille, France
关键词
Ultrasonic transducer arrays; Crosstalk; Transient regime;
D O I
10.1016/j.ultras.2013.09.007
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes a procedure to extend the crosstalk correction method presented in a previous paper [A. Bybi, S. Grondel, J. Assaad, A.-C. Hladky-Hennion, M. Rguiti, Reducing crosstalk in array structures by controlling the excitation voltage of individual elements: a feasibility study, Ultrasonics, 53 (6) (2013) 1135-1140] from the harmonic regime to the transient one. For this purpose a part of an ultrasonic transducer array radiating in water is modeled around the frequency 0.5 MHz using the finite element method. The study is carried out at low frequency in order to respect the same operating conditions than the previous paper. This choice facilitated the fabrication of the transducer arrays and the comparison of the numerical results with the experimental ones. The modeled array is composed of seventeen elements with the central element excited, while the others are grounded. The matching layers and the backing are not taken into account which limits the crosstalk only to the piezoelectric elements and fluid. This consideration reduces the structure density mesh and results in faster computation time (about 25 min for each configuration using a computer with a processor Intel Core i5-3210M, frequency 2.5 GHz and having 4 Go memory (RAM)). The novelty of this research work is to prove the efficiency of the crosstalk correction method in large frequency band as it is the case in medical imaging. The numerical results show the validity of the approach and demonstrate that crosstalk can be reduced by at least 13 dB in terms of displacement. Consequently, the directivity pattern of the individual element can be improved. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:720 / 724
页数:5
相关论文
共 44 条
  • [1] Electrical method for crosstalk cancellation in transducer arrays
    Bybi, A.
    Granger, C.
    Grondel, S.
    Hladky-Hennion, A. -C.
    Assaad, J.
    NDT & E INTERNATIONAL, 2014, 62 : 115 - 121
  • [2] Study of Crosstalk in Linear Ultrasonic Transducer Arrays
    Celmer, Mateusz
    Opielinski, Krzysztof J.
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2015, 101 (01) : 46 - 54
  • [3] One-dimensional equivalent circuit for ultrasonic transducer arrays
    Bybi, Bdelmajid
    Mouhat, Ouadia
    Garoum, Mohammed
    Drissi, Hilal
    Grondel, Sebastien
    APPLIED ACOUSTICS, 2019, 156 : 246 - 257
  • [4] Adaptive Noise Cancellation in the Intercept Time-Slowness Domain for Eliminating Ultrasonic Crosstalk in a Transducer Array
    Nguyen, K. C. T.
    Le, Lawrence H.
    Sacchi, Mauricio D.
    Huynh, L. Q.
    Lou, E.
    5TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING IN VIETNAM, 2015, 46 : 32 - 35
  • [5] Characterization of one-dimensional capacitive micromachined ultrasonic immersion transducer arrays
    Jin, XC
    Oralkan, Ö
    Degertekin, FL
    Khuri-Yakub, BT
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2001, 48 (03) : 750 - 760
  • [6] One-dimensional capacitative micromachined ultrasonic transducer arrays for echographic probes
    Cianci, E
    Minotti, A
    Foglietti, V
    Caliano, G
    Pappalardo, M
    MICROELECTRONIC ENGINEERING, 2004, 73-4 : 502 - 507
  • [7] ULTRASONIC TRANSDUCER ARRAYS MADE FROM COMPOSITE PIEZOELECTRIC MATERIALS
    SHAULOV, A
    SMITH, WA
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1986, 33 (01) : 100 - 101
  • [8] Computing the transient field in solids radiated from arbitrarily structured transducer arrays
    Ouarradi, N
    Piwakowski, B
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 963 - 966
  • [9] Numerical simulation of the transient temperature field from an annular focused ultrasonic transducer
    Zhang, Q
    Li, FQ
    Feng, R
    Xu, JY
    Bai, J
    Wang, ZB
    Wang, YJ
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (04): : 585 - 589
  • [10] Initial pulse-echo imaging results with one-dimensional capacitive micromachined ultrasonic transducer arrays
    Oralkan, Ö
    Jin, XC
    Kaviani, K
    Ergun, AS
    Degertekin, FL
    Karaman, M
    Khuri-Yakub, BT
    2000 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2000, : 959 - 962