Magnetic resonance angiography of the abdominal aorta and its branches

被引:0
作者
Boudghène, F [1 ]
Tassart, M [1 ]
Bazot, M [1 ]
Farres, MT [1 ]
Faintuch, JM [1 ]
Gouny, P [1 ]
LeBlanche, AF [1 ]
Bigot, JM [1 ]
机构
[1] Hop Tenon, Serv Radiol, F-75970 Paris 20, France
来源
JOURNAL DE RADIOLOGIE | 1999年 / 80卷 / 09期
关键词
aorta; magnetic resonance; MR-angiography; gadolinium;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Technical aspects of 3D contrast-enhanced magnetic resonance angiography are exposed, detailing more particularly the pulse sequence used and the mode of injection of contrast agent. Then, various vascular territories are analyzed, and illustrated using various exemples of main pathologies observed in routine clinical practice: abdominal aorta, renal arteries, pelvic and mesenteric vessels, and peripheral arteries.
引用
收藏
页码:1011 / 1023
页数:13
相关论文
共 49 条
  • [1] Ultrafast contrast-enhanced three-dimensional MR angiography: State of the art
    Alley, MT
    Shifrin, RY
    Pelc, NJ
    Herfkens, RJ
    [J]. RADIOGRAPHICS, 1998, 18 (02) : 273 - 285
  • [2] Renal artery stenosis and accessory renal arteries:: Accuracy of detection and visualization with gadolinium-enhanced breath-hold MR angiography
    Bakker, J
    Beek, FJA
    Beutler, JJ
    Hené, RJ
    de Kort, GAP
    de Lange, EE
    Moons, KGM
    Mali, WPTM
    [J]. RADIOLOGY, 1998, 207 (02) : 497 - 504
  • [3] MULTICENTER TRIAL TO EVALUATE VASCULAR MAGNETIC-RESONANCE ANGIOGRAPHY OF THE LOWER-EXTREMITY
    BAUM, RA
    RUTTER, CM
    SUNSHINE, JH
    BLEBEA, JS
    BLEBEA, J
    CARPENTER, JP
    DICKEY, KW
    QUINN, SF
    GOMES, AS
    GRIST, TM
    MCNEIL, BJ
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1995, 274 (11): : 875 - 880
  • [4] Human aorta: Preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets
    Davis, CP
    Ladd, ME
    Romanowski, BJ
    Wildermuth, S
    Knoplioch, JF
    Debatin, JF
    [J]. RADIOLOGY, 1996, 199 (01) : 37 - 40
  • [5] Renal artery stenosis: Evaluation with breath-hold, three-dimensional, dynamic, gadolinium-enhanced versus three-dimensional, phase-contrast MR angiography
    DeCobelli, F
    Vanzulli, A
    Sironi, S
    Mellone, R
    Angeli, E
    Venturini, M
    Garancini, MP
    Quartagno, R
    Bianchi, G
    DelMaschio, A
    [J]. RADIOLOGY, 1997, 205 (03) : 689 - 695
  • [6] Douek P, 1996, Rev Prat, V46, P835
  • [7] FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE
    DOUEK, PC
    REVEL, D
    CHAZEL, S
    FALISE, B
    VILLARD, J
    AMIEL, M
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 431 - 437
  • [8] Breath-hold single-dose gadolinium-enhanced three-dimensional MR aortography: Usefulness of a timing examination and MR power injector
    Earls, JP
    Rofsky, NM
    DeCorato, DR
    Krinsky, GA
    Weinreb, JC
    [J]. RADIOLOGY, 1996, 201 (03) : 705 - 710
  • [9] MR-ANGIOGRAPHY AS THE SOLE METHOD IN EVALUATING ABDOMINAL AORTIC-ANEURYSMS - CORRELATION WITH CONVENTIONAL TECHNIQUES AND SURGERY
    ECKLUND, K
    HARTNELL, GG
    HUGHES, LA
    STOKES, KR
    FINN, JP
    [J]. RADIOLOGY, 1994, 192 (02) : 345 - 350
  • [10] Automated detection of bolus arrival and initiation of data acquisition in fast, three-dimensional, gadolinium-enhanced MR angiography
    Foo, TKF
    Saranathan, M
    Prince, MR
    Chenevert, TL
    [J]. RADIOLOGY, 1997, 203 (01) : 275 - 280