Are Blood Stream Infections Associated With an Increased Risk of Hemorrhagic Stroke in Patients With a Left Ventricular Assist Device?

被引:74
作者
Aggarwal, Ashim [1 ]
Gupta, Ankit [1 ]
Kumar, Shivani [1 ]
Baumblatt, Jane A. [2 ]
Pauwaa, Sunil [1 ]
Gallagher, Colleen [1 ]
Treitman, Adam [3 ]
Pappas, Pat [4 ]
Tatooles, Antone [4 ]
Bhat, Geetha [1 ]
机构
[1] Advocate Christ Med Ctr, Ctr Heart Transplant & Assist Devices, Oak Lawn, IL 60453 USA
[2] Univ Illinois, Dept Internal Med, Chicago, IL USA
[3] Advocate Christ Med Ctr, Dept Infect Dis, Oak Lawn, IL 60453 USA
[4] Advocate Christ Med Ctr, Dept Cardiothorac Surg, Oak Lawn, IL 60453 USA
关键词
INTRACEREBRAL HEMORRHAGE; INFLAMMATORY RESPONSE; CIRCULATORY SUPPORT; DEBAKEY VAD; HEART; COMPLICATIONS; MANAGEMENT; IMPLANTATION; INFARCTION; THERAPY;
D O I
10.1097/MAT.0b013e318260c6a6
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood stream infections (BSIs) are an important cause of morbidity and mortality in patients with left ventricular assist devices (LVADs). The aim of this study was to examine the correlation between hemorrhagic cerebrovascular accident (CVA) and BSI after implantation of LVAD for advanced heart failure (HF). This was a retrospective descriptive review of 87 patients with end-stage HF, who underwent implantation of HeartMate II continuous-flow LVAD over a 4 year period. Blood stream infections were diagnosed by serial blood cultures, and suspected neurological complications including CVAs were confirmed by neuroimaging. Extensive patient chart review was performed, and descriptive characteristics were analyzed using SPSS statistical software. The mean age of our study population was 62.3 +/- 12.8 years, and the majority of our patients were males (n = 75, 86.2%). The baseline characteristics were comparable in the patients with and without CVAs. Patients with BSI had a much greater incidence of CVA compared to patients without BSI (n = 13, 43.3% vs. n = 5, 10.0%; p < 0.0001). There was an increased mortality in patients with BSI than those without (n = 57, 65.5% vs. n = 30, 34.5%; p = 0.003). The risk of all CVAs (hemorrhagic/ischemic) was eight-fold (odds ratio [OR] = 7.9; 95% confidence interval [CI] = 2.4-25.5; p = 0.001] in patients with BSI. Patients with BSI had a > 20-fold risk of hemorrhagic CVA (OR = 24; 95% CI = 2.8-201.1; p = 0.03). Advanced HF patients with LVAD support who developed BSI need urgent evaluation and close monitoring for suspected neurological complications, particularly hemorrhagic CVA. ASAIO Journal 2012;58:509-513.
引用
收藏
页码:509 / 513
页数:5
相关论文
共 32 条
[1]   Treatment of warfarin-associated intracerebral hemorrhage:: Literature review and expert opinion [J].
Aguilar, Maria I. ;
Hart, Robert G. ;
Kase, Carlos S. ;
Freeman, William D. ;
Hoeben, Maj Barbara J. ;
Garcia, Rosa C. ;
Ansell, Jack E. ;
Mayer, Stephan A. ;
Norrving, Bo ;
Rosand, Jonathan ;
Steiner, Thorsten ;
Wijdicks, Eelco F. M. ;
Yamaguchi, Takenori ;
Yasaka, Masahiro .
MAYO CLINIC PROCEEDINGS, 2007, 82 (01) :82-92
[2]   Transitory immunologic response after implantation of the DeBakey VAD continuous-axial-flow pump [J].
Ankersmit, HJ ;
Wieselthaler, G ;
Moser, B ;
Gerlitz, S ;
Roth, G ;
Boltz-Nitulescu, G ;
Wolner, E .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (03) :557-561
[3]  
Barner HB, 1998, ANN THORAC SURG, V66, pS25
[4]   Guidelines for the management of spontaneous intracerebral hemorrhage in adults - 2007 update - A guideline from the American Heart Association/American Stroke Association Stroke Council, High Blood Pressure Research Council, and the Quality of Care and Outcomes in Research Interdisciplinary Working Group [J].
Broderick, Joseph ;
Connolly, Sander ;
Feldmann, Edward ;
Hanley, Daniel ;
Kase, Carlos ;
Krieger, Derk ;
Mayberg, Marc ;
Morgenstern, Lewis ;
Ogilvy, Christopher S. ;
Vespa, Paul ;
Zuccarello, Mario .
CIRCULATION, 2007, 116 (16) :E391-E413
[5]   Mechanical circulatory support device database of the International Society for Heart and Lung Transplantation: Third Annual Report - 2005 [J].
Deng, MC ;
Edwards, LB ;
Hertz, MI ;
Rowe, AW ;
Keck, BM ;
Kormos, R ;
Naftel, DC ;
Kirklin, JK ;
Taylor, DO .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (09) :1182-1187
[6]   Inflammatory response to cardiopulmonary bypass [J].
Edmunds, LH .
ANNALS OF THORACIC SURGERY, 1998, 66 (05) :S12-S16
[7]   Ventricular thrombus and subarachnoid bleeding during support with ventricular assist devices [J].
Gruber, EM ;
Seitelberger, R ;
Mares, P ;
Hiesmayr, MJ .
ANNALS OF THORACIC SURGERY, 1999, 67 (06) :1778-1780
[8]   Complement activation in coronary artery bypass grafting patients without cardiopulmonary bypass - The role of tissue injury by surgical incision [J].
Gu, YJ ;
Mariani, MA ;
Boonstra, PW ;
Grandjean, JG ;
van Oeveren, W .
CHEST, 1999, 116 (04) :892-898
[9]   Systemic consequences of ventricular assist devices: Alterations of coagulation, immune function, inflammation, and the neuroendocrine system [J].
Hampton, CR ;
Verrier, ED .
ARTIFICIAL ORGANS, 2002, 26 (11) :902-908
[10]  
HART RG, 1987, TEX HEART I J, V14, P63