Electrochemical methods for on-site corrosion detection

被引:19
作者
Andrade, Carmen [1 ]
机构
[1] Int Ctr Numer Methods Engn CIMNE, Barcelona, Spain
关键词
corrosion rate; electrochemical techniques; linear polarization; maintenance surveys; on-site values; POLARIZATION RESISTANCE; CONCRETE; REINFORCEMENT; RESISTIVITY; SENSORS;
D O I
10.1002/suco.201900426
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The corrosion mechanism is of electrochemical nature and then, electrochemical techniques are the most adequate to measure the process and quantify it. In present paper are briefly described the most applied on site: corrosion potential, resistivity, galvanic current, and polarization resistance. In general, due to the difficulty to measure quasi-infinite in size reinforcement, the measurements are made on probes embedded in the cover attached to the bars. From the techniques used, only linear polarization is quantitative. Corrosion potential provides information about the corrosion risk, and resistivity is directly related with the concrete water content. The galvanic current is misleading if real size of anode and cathode are unknown. Although, frequently mistaken, galvanic current is not equal to corrosion rate and reference to areas involved is needed. Two examples are described on the monitoring of these methods.
引用
收藏
页码:1385 / 1395
页数:11
相关论文
共 16 条
  • [1] Some principles of service life calculation of reinforcements and in situ corrosion monitoring by sensors in the radioactive waste containers of El Cabril disposal (Spain)
    Andrade, C.
    Martinez, I.
    Castellote, M.
    Zuloaga, P.
    [J]. JOURNAL OF NUCLEAR MATERIALS, 2006, 358 (2-3) : 82 - 95
  • [2] Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method
    Andrade, C
    Alonso, C
    Gulikers, J
    Polder, R
    Cigna, R
    Vennesland, O
    Salta, M
    Raharinaivo, A
    Elsener, B
    [J]. MATERIALS AND STRUCTURES, 2004, 37 (273) : 623 - 643
  • [3] QUANTITATIVE MEASUREMENTS OF CORROSION RATE OF REINFORCING STEELS EMBEDDED IN CONCRETE USING POLARIZATION RESISTANCE MEASUREMENTS
    ANDRADE, C
    GONZALEZ, JA
    [J]. WERKSTOFFE UND KORROSION-MATERIALS AND CORROSION, 1978, 29 (08): : 515 - 519
  • [4] Andrade C, 1988, P C CORR RAT STEEL C
  • [5] [Anonymous], C87615 ASTM
  • [6] CONTECVET, 2001, MAN VAL US MAN ASS R
  • [7] Half-cell potential measurements - Potential mapping on reinforced concrete structures
    Elsener, B
    Andrade, C
    Gulikers, J
    Polder, R
    Raupach, M
    [J]. MATERIALS AND STRUCTURES, 2003, 36 (261) : 461 - 471
  • [8] Feliu S, 1996, J APPL ELECTROCHEM, V26, P305
  • [9] FELIU S, 1990, ACI MATER J, V87, P457
  • [10] A new method for in-situ measurement of electrical resistivity of reinforced concrete
    Feliu, S
    Andrade, C
    González, JA
    Alonso, C
    [J]. MATERIALS AND STRUCTURES, 1996, 29 (190) : 362 - 365