Dual-Energy CT in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair

被引:4
|
作者
Braegelmann, A. [1 ]
Bunck, A. [1 ,2 ]
Donas, K. [3 ]
Kasprzak, B. [3 ]
Maintz, D. [1 ,2 ]
Heindel, W. [1 ]
Seifarth, H. [1 ]
机构
[1] Univ Klinikum Munster, Inst Klin Radiol, D-48149 Munster, Germany
[2] Univ Klinikum Koln, Inst & Poliklin Radiol Diagnost, Cologne, Germany
[3] Univ Klinikum Munster, Klin Vaskulare & Endovaskulare Chirurg, D-48149 Munster, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2013年 / 185卷 / 04期
关键词
aorta; CT angiography; aneurysm; CONTRAST-ENHANCED ULTRASOUND; COMPUTED-TOMOGRAPHY; ENDOLEAK DETECTION; CLASSIFICATION; SURVEILLANCE; MANAGEMENT; SOCIETY; EVAR;
D O I
10.1055/s-0032-1330447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigates the dual-energy procedure for postoperative CT follow-up scans after endovascularly treated abdominal aortic aneurysms. The procedure is analyzed with respect to its sensitivity and specificity as well as the associated radiation exposure. Materials and Methods: 51 examinations were carried out on 47 patients between February 2009 and March 2010. For each patient, a non-enhanced, an arterial and a venous scan were conducted, the latter two using the dual-energy technology. Virtual images for the non-enhanced phase were reconstructed from the data taken in the venous phase. Protocol A, the reference standard, consisted of non-enhanced images and images of the arterial and venous phase. In protocol B, standard non-enhanced images were replaced by the reconstructed virtual non-enhanced images. Protocol C consisted only of virtual non-enhanced and 80 kV images taken during the venous phase. All data was anonymized and evaluated by two independent radiologists. For protocol C, sensitivity, specificity, negative and positive predictive values were computed. The effective radiation dosage was determined for each scan. Results: All endoleaks identified in protocol A were found using protocols B and C. For protocol C, the sensitivity and negative predictive value were 100%, the specificity was 94.1%, and the positive predictive value was 89.5%. Compared to protocol A, protocol C reduces the radiation exposure by 62.45%. Conclusion: A scan protocol consisting of virtual non-enhanced images as well as 80 kV images taken during the venous phase was found to be a reliable alternative method for diagnosing endoleaks, while reducing the radiation exposure by 62.45%.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [41] Complete ten-year follow-up after endovascular abdominal aortic aneurysm repair: Survival and causes of death
    Wibmer, Andreas
    Nolz, Richard
    Teufelsbauer, Harald
    Kretschmer, Georg
    Prusa, Alexander M.
    Funovics, Martin
    Lammer, Johannes
    Schoder, Maria
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (06) : 1203 - 1206
  • [42] Evaluation of Texture for Classification of Abdominal Aortic Aneurysm After Endovascular Repair
    Garcia, Guillermo
    Maiora, Josu
    Tapia, Arantxa
    De Blas, Mariano
    JOURNAL OF DIGITAL IMAGING, 2012, 25 (03) : 369 - 376
  • [43] Duplex ultrasound for surveillance after endovascular repair of abdominal aortic aneurysm
    Bevis, P. M.
    Cooper, D. G.
    ITALIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2012, 19 (04): : 237 - 243
  • [44] Imaging Follow-up of Endovascular Repair of Type B Aortic Dissection with Dual-Source, Dual-Energy CT and Late Delayed-Phase Scans
    Flors, Lucia
    Leiva-Salinas, Carlos
    Norton, Patrick T.
    Patrie, James T.
    Hagspiel, Klaus D.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (03) : 435 - 442
  • [45] Maximum Diameter Measurements of Aortic Aneurysms on Axial CT Images After Endovascular Aneurysm Repair: Sufficient for Follow-up?
    Stephan Baumueller
    Thi Dan Linh Nguyen
    Robert Paul Goetti
    Mario Lachat
    Burkhardt Seifert
    Thomas Pfammatter
    Thomas Frauenfelder
    CardioVascular and Interventional Radiology, 2011, 34 : 1182 - 1189
  • [46] A limited and customized follow-up seems justified after endovascular abdominal aneurysm repair in octogenarians
    Visser, Linda
    Pol, Robert A.
    Tielliu, Ignace F. J.
    van den Dungen, Jan J. A. M.
    Zeebregts, Clark J.
    JOURNAL OF VASCULAR SURGERY, 2014, 59 (05) : 1232 - 1240
  • [47] Comparison of contrast-enhanced ultrasound and compression elastography in the follow-up after endovascular aortic aneurysm repair
    Guertler, V. M.
    Rjosk-Dendorfer, D.
    Reiser, M.
    Clevert, D. A.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2014, 57 (02) : 175 - 183
  • [48] Dual-Energy CT Follow-Up After Stroke Thrombolysis Alters Assessment of Hemorrhagic Complications
    Almqvist, Hakan
    Almqvist, Niklas S.
    Holmin, Staffan
    Mazya, Michael, V
    FRONTIERS IN NEUROLOGY, 2020, 11
  • [49] Telemedicine for screening and follow-up of abdominal aortic aneurysm
    Sterpetti, Antonio V.
    JOURNAL OF VASCULAR SURGERY, 2022, 75 (04) : 1497 - 1497
  • [50] Textural Classification of Abdominal Aortic Aneurysm after Endovascular Repair: Preliminary Results
    Garcia, Guillermo
    Maiora, Josu
    Tapia, Arantxa
    De Blas, Mariano
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS: 14TH INTERNATIONAL CONFERENCE, CAIP 2011, PT I, 2011, 6854 : 537 - 544