Dual-Energy CT in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair

被引:4
|
作者
Braegelmann, A. [1 ]
Bunck, A. [1 ,2 ]
Donas, K. [3 ]
Kasprzak, B. [3 ]
Maintz, D. [1 ,2 ]
Heindel, W. [1 ]
Seifarth, H. [1 ]
机构
[1] Univ Klinikum Munster, Inst Klin Radiol, D-48149 Munster, Germany
[2] Univ Klinikum Koln, Inst & Poliklin Radiol Diagnost, Cologne, Germany
[3] Univ Klinikum Munster, Klin Vaskulare & Endovaskulare Chirurg, D-48149 Munster, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2013年 / 185卷 / 04期
关键词
aorta; CT angiography; aneurysm; CONTRAST-ENHANCED ULTRASOUND; COMPUTED-TOMOGRAPHY; ENDOLEAK DETECTION; CLASSIFICATION; SURVEILLANCE; MANAGEMENT; SOCIETY; EVAR;
D O I
10.1055/s-0032-1330447
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study investigates the dual-energy procedure for postoperative CT follow-up scans after endovascularly treated abdominal aortic aneurysms. The procedure is analyzed with respect to its sensitivity and specificity as well as the associated radiation exposure. Materials and Methods: 51 examinations were carried out on 47 patients between February 2009 and March 2010. For each patient, a non-enhanced, an arterial and a venous scan were conducted, the latter two using the dual-energy technology. Virtual images for the non-enhanced phase were reconstructed from the data taken in the venous phase. Protocol A, the reference standard, consisted of non-enhanced images and images of the arterial and venous phase. In protocol B, standard non-enhanced images were replaced by the reconstructed virtual non-enhanced images. Protocol C consisted only of virtual non-enhanced and 80 kV images taken during the venous phase. All data was anonymized and evaluated by two independent radiologists. For protocol C, sensitivity, specificity, negative and positive predictive values were computed. The effective radiation dosage was determined for each scan. Results: All endoleaks identified in protocol A were found using protocols B and C. For protocol C, the sensitivity and negative predictive value were 100%, the specificity was 94.1%, and the positive predictive value was 89.5%. Compared to protocol A, protocol C reduces the radiation exposure by 62.45%. Conclusion: A scan protocol consisting of virtual non-enhanced images as well as 80 kV images taken during the venous phase was found to be a reliable alternative method for diagnosing endoleaks, while reducing the radiation exposure by 62.45%.
引用
收藏
页码:351 / 357
页数:7
相关论文
共 50 条
  • [1] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Buffa, Vitaliano
    Solazzo, Antonio
    D'Auria, Valeria
    Del Prete, Alessandra
    Vallone, Andrea
    Luzietti, Monica
    Madau, Manuela
    Grassi, Roberto
    Miele, Vittorio
    RADIOLOGIA MEDICA, 2014, 119 (12): : 934 - 941
  • [2] Systematic review of follow-up compliance after endovascular abdominal aortic aneurysm repair
    Spanos, Konstantinos
    Karathanos, Christos
    Athanasoulas, Athanasios
    Sapeltsis, Vasileios
    Giannoukas, Athanasios D.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2018, 59 (04) : 611 - 618
  • [3] Role of Contrast-Enhanced Ultrasound in the Follow-Up after Endovascular Abdominal Aortic Aneurysm Repair
    Benedetto, Filippo
    Spinelli, Domenico
    La Corte, Francesco
    Pipito, Narayana
    Passari, Gabriele
    De Caridi, Giovanni
    DIAGNOSTICS, 2022, 12 (12)
  • [4] Endovascular Abdominal Aortic Aneurysm Repair: Nonenhanced Volumetric CT for Follow-up
    Bley, Thorsten A.
    Chase, Peter J.
    Reeder, Scott B.
    Francois, Christopher J.
    Shinki, Kazuhiko
    Tefera, Girma
    Ranallo, Frank N.
    Grist, Thomas M.
    Pozniak, Myron
    RADIOLOGY, 2009, 253 (01) : 253 - 262
  • [5] Dual-source dual-energy CT: dose reduction after endovascular abdominal aortic aneurysm repair
    Vitaliano Buffa
    Antonio Solazzo
    Valeria D’Auria
    Alessandra Del Prete
    Andrea Vallone
    Monica Luzietti
    Manuela Madau
    Roberto Grassi
    Vittorio Miele
    La radiologia medica, 2014, 119 : 934 - 941
  • [6] Follow-up compliance after endovascular abdominal aortic aneurysm repair in Medicare beneficiaries
    Schanzer, Andres
    Messina, Louis M.
    Ghosh, Kaushik
    Simons, Jessica P.
    Robinson, William P., III
    Aiello, Francesco A.
    Goldberg, Robert J.
    Rosen, Allison B.
    JOURNAL OF VASCULAR SURGERY, 2015, 61 (01) : 16 - U343
  • [7] Abdominal aortic aneurysm follow-up by shear wave elasticity imaging after endovascular repair in a canine model
    Bertrand-Grenier, Antony
    Lerouge, Sophie
    Tang, An
    Salloum, Eli
    Therasse, Eric
    Kauffmann, Claude
    Heon, Helene
    Salazkin, Igor
    Cloutier, Guy
    Soulez, Gilles
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 2161 - 2169
  • [8] Endovascular Repair of Abdominal Aortic Aneurysm: Follow-up with Noninvasive Vascular Elastography in a Canine Model
    Salloum, Eli
    Bertrand-Grenier, Antony
    Lerouge, Sophie
    Kauffman, Claude
    Heon, Helene
    Therasse, Eric
    Salazkin, Igor
    Cardinal, Marie-Helene Roy
    Cloutier, Guy
    Soulez, Gilles
    RADIOLOGY, 2016, 279 (02) : 410 - 419
  • [9] Contemporary imaging methods for the follow-up after endovascular abdominal aneurysm repair: a review
    Kazimierczak, Wojciech
    Serafin, Zbigniew
    Kazimierczak, Natalia
    Ratajczak, Przemyslaw
    Leszczynski, Waldemar
    Bryl, Lukasz
    Lemanowicz, Adam
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2019, 14 (01) : 1 - 11
  • [10] Role of multidetector CT angiography and contrast-enhanced ultrasound in redefining follow-up protocols after endovascular abdominal aortic aneurysm repair
    Motta, R.
    Rubaltelli, L.
    Vezzaro, R.
    Vida, V.
    Marchesi, P.
    Stramare, R.
    Zanon, A.
    Battistel, M.
    Sommavilla, M.
    Miotto, D.
    RADIOLOGIA MEDICA, 2012, 117 (06): : 1079 - 1092