A prospective study of a new presbyopia pseudophakic intraocular lens: Safety, efficacy and satisfaction

被引:2
作者
Bianchi, German R. [1 ]
机构
[1] Clin Ojos Dr Nano, Centro Panamer, Buenos Aires, DF, Argentina
关键词
Cataract surgery; multifocal intraocular lens; presbyopia; pseudophakic intraocular lens; refractive surgery; DEPTH-OF-FOCUS; EXTENDED DEPTH; OUTCOMES; IOL;
D O I
10.4103/ijo.IJO_2795_21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the safety, visual performance, and patient satisfaction of a new presbyopic pseudophakic intraocular lens (IOL). Methods: A prospective non-randomized case-series study was performed in Buenos Aires, Argentina. Patients included in the study underwent a programmed Femtosecond laser assisted cataract surgery (FLACS), performed between October and December 2020, with a 6-month follow-up period. The Intensity (Hanita Lenses) IOL was bilaterally implanted. Spherical equivalent (SE) refraction, uncorrected distance and near visual acuity (UDVA/UNVA), defocus curve, endothelial cell density (ECD), central corneal thickness (CCT), and a satisfaction questionnaire were evaluated. Results: A total of 56 patients (112 eyes), aged 65 +/- 6.12 years were included. The mean +/- SD of preoperative SE was 1.85 +/- 2.24 D (range; -4.50 to 4.75), which had decreased 6 months after surgery to -0.08 +/- 0.32 D (range; -0.75 to 0.63). No eyes experienced a loss of lines of vision, and 94% obtained SE values between +/- 0.50 D. Defocus curve for different additions was 0.03 LogMAR (logarithm of the minimum angle of resolution) for -3.0 D, -0.005 LogMAR for -1.5 D, and -0.07 LogMAR for 0 D. The ECD, CCT remained stable (P: 0.09 and 0.58, respectively) and all patients achieved their preoperative expectations, with a 6-month follow-up period. Conclusion: Patients who underwent a safe bilateral implantation with Intensity IOL achieved a high degree of spectacle independence and satisfaction, 6 months after surgery.
引用
收藏
页码:3305 / 3310
页数:6
相关论文
共 50 条
  • [21] Comparison of a Presbyopia-Correcting Supplementary Intraocular Lens Combination and a Capsular-Bag Lens: An In Vitro Study
    Khoramnia, Ramin
    Baur, Isabella Diana
    Yan, Weijia
    Labuz, Grzegorz
    Auffarth, Gerd Uwe
    DIAGNOSTICS, 2023, 13 (08)
  • [22] Performance of a New-Generation Extended Depth of Focus Intraocular Lens-A Prospective Comparative Study
    Nivean, Madhivanan
    Nivean, Pratheeba Devi
    Reddy, Jagadeesh Kumar
    Ramamoorthy, Kavithaa
    Madhivanan, Nishanth
    Rajan, Mohan
    Sengupta, Sabyasachi
    ASIA-PACIFIC JOURNAL OF OPHTHALMOLOGY, 2019, 8 (04): : 285 - 289
  • [23] Clinical outcomes of a new four-haptic hydrophobic presbyopia-correcting intraocular lens
    Whang, Woong-Joo
    Kim, Tae-im
    Tchah, Hungwon
    Koh, Kyungmin
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [24] Visual Quality, Patient Satisfaction, and Photic Phenomena With a Diffractive Intraocular Lens and Its New Evolved Materials Version
    Rementeria-Capelo, Laureano A.
    Contreras, Ines
    Gros-Otero, Juan
    Marinas, Laura
    Ruiz-Alcocer, Javier
    JOURNAL OF REFRACTIVE SURGERY, 2024, 40 (11) : e877 - e883
  • [25] Clinical safety and efficacy of a hydrophilic acrylic intraocular lens in a real-world population: a 1-year follow-up retro-prospective study
    Johansson, Bjorn
    Daniel, Ana C. S.
    Herbers, Claudia
    Gerl, Matthias
    Kretz, Florian T. A.
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [26] Prospective multicenter trial assessing effectiveness, refractive predictability and safety of a new aberration free, bi-aspheric intraocular lens
    Brown, David C.
    Gills, J. Pit, III
    Trattler, William B.
    Newsom, T. Hunter
    Weinstock, Robert J.
    Sanders, Donald R.
    CONTACT LENS & ANTERIOR EYE, 2011, 34 (04) : 188 - 192
  • [27] Peripheral Refraction and Contrast Detection Sensitivity in Pseudophakic Patients Implanted With a New Meniscus Intraocular Lens
    Villegas, Eloy A.
    Marin, Jose M.
    Ginis, Harilaos
    Robles, Consuelo
    Alcon, Encarna
    Hervella, Lucia
    Prieto, Pedro M.
    Tana-Rivero, Pedro
    Artal, Pablo
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (04) : 229 - 234
  • [28] Efficacy and safety of intraocular folding sutureless scleral fixating lens versus iris-claw intraocular lens implantation
    Bodin, S.
    Bourdon, H.
    Bennedjai, A.
    Akesbi, J.
    Rodallec, T.
    Robin, Mathieu
    Scheer, S.
    Leleu, I.
    Adam, R.
    Nordmann, J. -P.
    JOURNAL FRANCAIS D OPHTALMOLOGIE, 2022, 45 (04): : 392 - 397
  • [29] Safety and Efficacy of a New Posterior Chamber Phakic Intraocular Lens in Cases of High Myopia: Early Results
    Subudhi, Praveen
    Patro, Sweta
    Agarwal, Prateek
    Khan, Zahiruddin
    Subudhi, B. Nageswar Rao
    Mekap, Chandan
    Padhi, Asutosh
    CLINICAL OPHTHALMOLOGY, 2020, 14 : 3681 - 3689
  • [30] Safety, biocompatibility, and potential functionality of a new accommodative intraocular lens: An experimental study in rabbits
    Fernandez-Bueno, Ivan
    Olcina, Luis Ignacio
    Andres-Iglesias, Cristina
    Puertas-Neyra, Kevin
    Fernandez-Martinez, Itziar
    Usategui-Martin, Ricardo
    Maldonado-Lopez, Miguel Jose
    HELIYON, 2023, 9 (09)