Devices for thoracic endovascular aortic repair of type B aortic dissection: is there any chance for Marfan syndrome?

被引:7
作者
Lovato, Luigi [1 ,2 ]
Cefarelli, Mariano [3 ,4 ]
Gatta, Emanuele [5 ,6 ]
Di Eusanio, Marco [3 ,4 ]
Fattori, Rossella [7 ]
机构
[1] Univ Bologna, Cardiothorac Vasc Dept, Cardiovasc Radiol Unit, S Orsola Malpighi Hosp, Bologna, Italy
[2] Univ Bologna, Marfan Ctr, S Orsola Malpighi Hosp, Bologna, Italy
[3] Polytech Univ Marche, Cardiovasc Dept, Cardiac Surg Unit, Lancisi Cardiovasc Ctr, Ancona, Italy
[4] Polytech Univ Marche, Marfan Ctr, Lancisi Cardiovasc Ctr, Ancona, Italy
[5] Lancisi Cardiovasc Ctr, Cardiovasc Dept, Vasc Surg Unit, Ancona, Italy
[6] Lancisi Cardiovasc Ctr, Marfan Ctr, Ancona, Italy
[7] Polytech Univ Marche, Cardiovasc Dept, Marfan Ctr, Lancisi Cardiovasc Ctr, Ancona, Italy
关键词
Aortic dissection; conformability; device; endovascular treatment; false lumen; Marfan Syndrome; remodeling; TEVAR; thoracic endografts; STENT-GRAFT PLACEMENT; MULTICENTER CLINICAL-TRIAL; INTERNATIONAL REGISTRY; MIDTERM OUTCOMES; DESCENDING AORTA; EXPERIENCE; ENTRY; ARCH; ANEURYSM; SURVIVAL;
D O I
10.1080/17434440.2020.1782735
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction Type B aortic dissection (TBAD) is a threatening event that may lead to death for aortic rupture or multivisceral malperfusion in the acute phase and offers a poor prognosis for long term survivors. Thoracic endovascular aortic repair (TEVAR) has become the preferential therapy in acute and chronic complicated cases for its less invasivity compared to open surgery. However TEVAR is still encumbered by a significant number of reinterventions, caused by aortic neck aneurysmal degeneration, endoleaks and stent-graft induced new entry (SINE). This is even more true in patients with particularly fragile aortic wall like Marfan Syndrome (MS) in contrast to the excellent results of elective open surgery. Areas covered This review analyzes the current available TEVAR devices and techniques in TBAD and their technological advancements, especially those most suitable to TBAD anatomy, according to current literature. Expert opinion The continuous technological evolution of materials and device solutions ensures solid results of TEVAR in acute TBAD and may also potentially overcome some of the limitations of endovascular devices in this setting, paving the way for safer and more durable results and allowing for expanded indications in the future, even in the delicate population of collagenopathies, especially in MS.
引用
收藏
页码:683 / 696
页数:14
相关论文
共 81 条
  • [1] Evolution and future of preclinical testing for endovascular grafts
    Abel, Dorothy B.
    Dehdashtian, Mark M.
    Rodger, Stuart T.
    Smith, Angela C.
    Smith, Louis J.
    Waninger, Matthew S.
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2006, 13 (05) : 649 - 659
  • [2] Image fusion using the two-dimensional-three-dimensional registration method helps reduce contrast medium volume, fluoroscopy time, and procedure time in hybrid thoracic endovascular aortic repairs
    Ahmad, Wael
    Hasselmann, Hans-Christian
    Galas, Noemi
    Majd, Payman
    Brunkwall, Silke
    Brunkwall, Jan Sigge
    [J]. JOURNAL OF VASCULAR SURGERY, 2019, 69 (04) : 1003 - 1010
  • [3] Experience of the Zenith Dissection Endovascular System in the emergency setting of malperfusion in acute type B dissections
    Alsac, Jean-Marc
    Girault, Antoine
    El Batti, Salma
    Abou Rjeili, Marwan
    Alomran, Faris
    Achouh, Paul
    Julia, Pierre
    Fabiani, Jean-Noel
    [J]. JOURNAL OF VASCULAR SURGERY, 2014, 59 (03) : 645 - 650
  • [4] Patient outcomes and thoracic aortic volume and morphologic changes following thoracic endovascular aortic repair in patients with complicated chronic type B aortic dissection
    Andacheh, Iden David
    Donayre, Carlos
    Othman, Fiezel
    Walot, Irwin
    Kopchok, George
    White, Rodney
    [J]. JOURNAL OF VASCULAR SURGERY, 2012, 56 (03) : 644 - 650
  • [5] [Anonymous], 2014, EUR J VASC ENDOVASC, V48, P363, DOI DOI 10.1016/j.ejvs.2014.05.007
  • [6] GORE TAG Thoracic Endograft with Active Control System: Landing Accuracy and Wall Apposition in an Initial Clinical Experience
    Antonello, Michele
    Squizzato, Francesco
    Dall'Antonia, Alberto
    Grego, Franco
    Piazza, Michele
    [J]. ANNALS OF VASCULAR SURGERY, 2019, 58 : 261 - 269
  • [7] Outcomes of Thoracic Endovascular Aortic Repair in Acute Type B Aortic Dissection: Results From the Valiant United States Investigational Device Exemption Study
    Bavaria, Joseph E.
    Brinkman, William T.
    Hughes, G. Chad
    Khoynezhad, Ali
    Szeto, Wilson Y.
    Azizzadeh, Ali
    Lee, W. Anthony
    White, Rodney A.
    [J]. ANNALS OF THORACIC SURGERY, 2015, 100 (03) : 802 - 809
  • [8] The PETTICOAT concept for endovascular treatment of type B aortic dissection
    Bertoglio, Luca
    Rinaldi, Enrico
    Melissano, Germano
    Chiesa, Roberto
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2019, 60 (01) : 91 - 99
  • [9] Early Experience With the First Commercially Available Off-the-Shelf Multibranched Endograft (t-Branch) in the Treatment of Thoracoabdominal Aortic Aneurysms
    Bosiers, Michel J.
    Bisdas, Theodosios
    Donas, Konstantinos P.
    Torsello, Giovanni
    Austermann, Martin
    [J]. JOURNAL OF ENDOVASCULAR THERAPY, 2013, 20 (06) : 719 - 725
  • [10] Stent graft repair of descending aortic dissection in patients with Marfan syndrome: An effective alternative to open reoperation?
    Botta, Luca
    Russo, Vincenzo
    La Palombara, Cesare
    Rosati, Marzia
    Di Bartolomeo, Roberto
    Fattori, Rossella
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 138 (05) : 1108 - 1114