Heat transfer characteristics in air-conditioned rooms using mixing air-distribution system under mixed convection conditions

被引:17
作者
Al-Sanea, Sami A. [1 ]
Zedan, M. F. [1 ]
Al-Harbi, M. B. [2 ]
机构
[1] King Saud Univ, Coll Engn, Dept Mech Engn, Riyadh 11421, Saudi Arabia
[2] King Abdulaziz City Sci & Technol, Natl Satellite Technol Program, Riyadh 11442, Saudi Arabia
关键词
Room ventilation; Mixing air-distribution system; Heat removal index; Mixed convection; CFD simulation; 2-LAYER TURBULENCE MODEL; FLOW; VENTILATION; BUOYANCY; PREDICTION;
D O I
10.1016/j.ijthermalsci.2012.04.023
中图分类号
O414.1 [热力学];
学科分类号
摘要
The present paper deals with CFD study of flow and thermal characteristics in air-conditioned rooms under turbulent mixed convection conditions. Air enters room from a sidewall slot flush with isothermal ceiling and leaves through a slot in opposite wall flush with floor. Velocity and temperature distributions are determined by a CFD model that has been previously validated by comparison with experimental data. Rigorous dimensional analysis shows that performance of the air-distribution system depends on: supply Reynolds number Re-d, Grashof number Gr(d) (or Archimedes number Ar-d), room aspect ratio L/H, dimensionless heights of supply and return ports (d/H and t/H), where H is room height. For a room with fixed geometry, the effects of Re-d and Gr(d) (or Ar-d) are investigated systematically by varying one parameter at a time. Results show that ceiling average Nusselt number (Nu(d,av)) increases with Re-d and decreases with Gr(d) (or Ar-d). For a given Gr(d), the heat removal index (HRI) increases with Re-d up to Re-d approximate to 9000, then stays practically constant thereafter. For a given Re-d, HRI decreases with increasing Gr(d) (or Ar-d). A criterion for distinction between forced and mixed convection situations is developed, resulting in a critical Archimedes number of 0.11. Results further indicate that Ar-d alone, irrespective of the particular values of Re-d and Gr(d), determines to a reasonable extent Nu(d,av) and HRI when Ar-d is above its critical value. Streamlines and temperature contours are found to be consistent with other results and helped explain them. (C) 2012 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:247 / 259
页数:13
相关论文
共 28 条
[1]   Mixed convection heat transfer along a continuously moving heated vertical plate with suction or injection [J].
Al-Sanea, SA .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2004, 47 (6-7) :1445-1465
[2]   Convection regimes and heat transfer characteristics along a continuously moving heated vertical plate [J].
Al-Sanea, SA .
INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2003, 24 (06) :888-901
[3]   Effect of supply Reynolds number and room aspect ratio on flow and ceiling heat-transfer coefficient for mixing ventilation [J].
Al-Sanea, Sami A. ;
Zedan, M. F. ;
Al-Harbi, M. B. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 54 :176-187
[4]  
Awbi H.B., 1991, VENTILATION BUILDING
[5]   SCALE EFFECT IN ROOM AIR-FLOW STUDIES [J].
AWBI, HB ;
NEMRI, MM .
ENERGY AND BUILDINGS, 1990, 14 (03) :207-210
[6]   Investigation of room air flow regarding effects of occupants, inlet/outlet locations, inlet velocity, and winter/summer conditions [J].
Baskaya, S ;
Eken, E .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2003, 30 (08) :1147-1156
[7]  
Chen GY, 1998, ENERG BUILDINGS, V28, P137
[8]   COMPARISON OF DIFFERENT K-EPSILON MODELS FOR INDOOR AIR-FLOW COMPUTATIONS [J].
CHEN, Q .
NUMERICAL HEAT TRANSFER PART B-FUNDAMENTALS, 1995, 28 (03) :353-369
[9]   Test of several versions for the k-ε type turbulence modelling of internal mixed convection flows [J].
Costa, JJ ;
Oliveira, LA ;
Blay, D .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1999, 42 (23) :4391-4409
[10]   Turbulent airflow in a room with a two-jet heating-ventilation system - a numerical parametric study [J].
Costa, JJ ;
Oliveira, LA ;
Blay, D .
ENERGY AND BUILDINGS, 2000, 32 (03) :327-343