Advantages of a logarithmic sampling scheme for XPCS experiments at the European XFEL using the AGIPD detector

被引:7
作者
Becker, J. [1 ]
Graafsma, H. [1 ]
机构
[1] DESY, D-22607 Hamburg, Germany
关键词
Simulation methods and programs; Instrumentation for FEL; Detector modelling and simulations I (interaction of radiation with matter; interaction of photons with matter; interaction of hadrons with matter; etc); PHOTON-CORRELATION; SIMULATION;
D O I
10.1088/1748-0221/7/04/P04012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The European XFEL, currently under construction, will produce a coherent X-ray pulse every 220 ns in pulse trains of up to 2700 pulses. In conjunction with the fast 2D area detectors currently under development, it will be possible to perform X-ray Photon Correlation Spectroscopy experiments on sub-microsecond timescales with non-ergodic systems. The Adaptive Gain Integrating Pixel Detector (AGIPD) will be able to record approximately 350 images of every pulse train. This study investigates the influence of the sampling scheme (linear/logarithmic) on the data quality for the AGIPD and possible second generation modifications for XPCS experiments. It is observed that employing the logarithmic sampling significantly reduces the error of the determined relaxation times above approximately 10 mu s due to the larger accessible time base (approximately factor 9 larger compared to the linear scheme). No significant difference between the errors of smaller determined relaxation times was observed, although the linear scheme produced data of higher fidelity (larger signal to noise ratio). In conclusion the use of a logarithmic sampling scheme is advantageous for the type of experiment investigated in this study.
引用
收藏
页数:28
相关论文
共 24 条
[1]  
Altarelli M., 2006, The European X-Ray Free-Electron Laser Technical Design Report
[2]   Simulation study of the impact of AGIPD design choices on X-ray Photon Correlation Spectroscopy utilizing the intensity autocorrelation technique [J].
Becker, J. ;
Gutt, C. ;
Graafsma, H. .
JOURNAL OF INSTRUMENTATION, 2011, 6
[3]  
Becker J., 2010, THESIS HAMBURG U
[4]   Simulation and experimental study of plasma effects in planar silicon sensors [J].
Becker, Julian ;
Gartner, Klaus ;
Klanner, Robert ;
Richter, Rainer .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 624 (03) :716-727
[5]   Measurements of charge carrier mobilities and drift velocity saturation in bulk silicon of ⟨1 1 1⟩ and ⟨1 0 0⟩ crystal orientation at high electric fields [J].
Becker, Julian ;
Fretwurst, Eckhart ;
Klanner, Robert .
SOLID-STATE ELECTRONICS, 2011, 56 (01) :104-110
[6]   Impact of plasma effects on the performance of silicon sensors at an X-ray FEL [J].
Becker, Julian ;
Eckstein, Doris ;
Klanner, Robert ;
Steinbrueck, Georg .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (02) :230-236
[7]  
Chushkin Y., 2011, XRAY PHOTON CO UNPUB
[8]   Optimizing the signal-to-noise ratio for X-ray photon correlation spectroscopy [J].
Falus, P ;
Lurio, LB ;
Mochrie, SGJ .
JOURNAL OF SYNCHROTRON RADIATION, 2006, 13 :253-259
[9]   Computational modelling of semiconducting X-ray detectors [J].
Fowler, RF ;
Ashby, JV ;
Greenough, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 477 (1-3) :226-231
[10]   Correlation spectroscopy with coherent X-rays [J].
Grübel, G ;
Zontone, F .
JOURNAL OF ALLOYS AND COMPOUNDS, 2004, 362 (1-2) :3-11