A Data-driven Approach for Estimating Power System Frequency and Amplitude Using Dynamic Mode Decomposition

被引:0
作者
Mohan, Neethu [1 ]
Soman, K. P. [1 ]
Kumar, Sachin S. [1 ]
机构
[1] Amrita Vishwa Vidyapeetham, Amrita Sch Engn, Ctr Computat Engn & Networking CEN, Coimbatore, Tamil Nadu, India
来源
PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON GREEN ENERGY FOR SUSTAINABLE DEVELOPMENT (ICUE 2018) | 2018年
关键词
Amplitude estimation; Dynamic mode decomposition; Frequency estimation; Power quality analysis; Smart grid; QUALITY DISTURBANCES; HILBERT TRANSFORM; ADAPTIVE FILTER; WAVELET; CLASSIFICATION; ALGORITHM; PHASOR;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To ensure power system stability, control and quality supply of power, it is essential to monitor power system parameters such as frequency and amplitude. This paper proposes a data-driven approach based on dynamic mode decomposition (DMD) algorithm for the accurate estimation of frequency and amplitude in smart grid. In the proposed approach, to extract the multiple frequency components, including harmonics, inter-harmonics and subharmonics, a stacked measurement matrix is created by appending multiple time-shifted versions of power signals. An optimal hard-thresholding is performed on the singular values of the measurement matrix to deal with the uncertainties and high-level noises. Further, the frequency and amplitude are computed based on the extracted dynamic modes. The performance of the proposed approach is confirmed through various experiments conducted on different power system scenarios under noisy and noiseless conditions. The effectiveness of the DMD based method is verified by comparing the results with several state-of-the-art methods. The promising results suggest that the proposed approach can be used as an efficient candidate for estimating the power system frequency and amplitude.
引用
收藏
页数:9
相关论文
共 41 条
[1]  
Achlerkar P. D., 2016, IEEE T SMART GRID
[2]   A new technique for unbalance current and voltage estimation with neural networks [J].
Alcántara, FJ ;
Salmerón, P .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) :852-858
[3]  
[Anonymous], 2015, POWER SYSTEMS SIGNAL
[4]   A Dynamic Mode Decomposition Framework for Global Power System Oscillation Analysis [J].
Barocio, Emilio ;
Pal, Bikash C. ;
Thornhill, Nina F. ;
Roman Messina, Arturo .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2015, 30 (06) :2902-2912
[5]   Interpolated-DFT-Based Fast and Accurate Frequency Estimation for the Control of Power [J].
Borkowski, Jozef ;
Kania, Dariusz ;
Mroczka, Janusz .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (12) :7026-7034
[6]   An Accurate Time-Domain Procedure for Harmonics and Interharmonics Detection [J].
Chang, Gary W. ;
Chen, Cheng-I .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (03) :1787-1795
[7]   A Two-Stage ADALINE for Harmonics and Interharmonics Measurement [J].
Chang, Gary W. ;
Chen, Cheng-I ;
Liang, Quan-Wei .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :2220-2228
[8]   Comparative Study of Harmonic and Interharmonic Estimation Methods for Stationary and Time-Varying Signals [J].
Chen, Cheng-I ;
Chen, Yeong-Chin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (01) :397-404
[9]  
DURIC MB, 2005, P POW TECH ST PET RU, P1
[10]   The Optimal Hard Threshold for Singular Values is 4/√3 [J].
Gavish, Matan ;
Donoho, David L. .
IEEE TRANSACTIONS ON INFORMATION THEORY, 2014, 60 (08) :5040-5053