Utility of Real-Time Shear Wave Elastography in the Assessment of Testicular Torsion

被引:39
作者
Sun, Zhenxing [1 ]
Xie, Mingxing [1 ]
Xiang, Feixiang [1 ]
Song, Yue [1 ]
Yu, Cheng [1 ]
Zhang, Yanrong [1 ]
Ramdhany, Sachin [1 ]
Wang, Jing [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Ultrasound, Union Hosp, Tongji Med Coll, Wuhan 430022, Peoples R China
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
ULTRASOUND ELASTOGRAPHY; BREAST MASSES; PEDIATRIC-PATIENTS; SONOGRAPHY; INFARCTION; LESIONS; US; ELASTICITY; DIAGNOSIS; DISEASE;
D O I
10.1371/journal.pone.0138523
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Real-time shear-wave elastography (SWE) is a newly developed method which can obtain the stiffness of tissues and organs based on tracking of shear wave propagation through a structure. Several studies have demonstrated its potential in the differentiation between diseased and normal tissue in clinical practices, however the applicability to testicular disease has not been well elucidated. We investigated the feasibility and reproducibility of SWE in the detection of testicular torsion. This prospective study comprised 15 patients with complete testicular torsion. Results obtained from SWE along with conventional gray-scale and color Doppler sonography and post-operative pathology were compared. The results revealed that (i) the size of injured testis was increased and the twisted testis parenchyma was heterogeneous. The blood flow signals in injured testis were barely visible or absent; (ii) The Young's modulus, including Emean, Emax, Emin and SD values in the border area of torsional testis were higher than those of normal testis (Emean, 78.07+/-9.01kPa vs 22.0 +/-5.10kPa; Emax, 94.07+/-6.53kPa vs 27.87+/-5.78kPa; Emin, 60.73+/-7.84 kPa vs 18.90 +/-4.39kPa; SD, 7.67+/-0.60 kPa vs 2.30+/-0.36 kPa, [P<0.05]); The Emax and SD values in the central area of the torsional testis were higher than the corresponding area of the normal testis (Emax, 8.23+/-0.30 kPa vs 3.97+/-0.95kPa; SD, 1.5+/-0.26kPa vs 0.67+/-0.35kPa, [P< 0.05])and Emin values was lower than those of normal testicles(0.93+/-0.51kPa vs 1.6 +/-0.36kPa; [P< 0.05]); (iii) The Young's modulus measurement between two physicians showed good agreement. The pathological findings were accordance with SWE measurement. SWE is a non-invasive, convenient and high reproducible method and may serve as an important alternative tool in the diagnosis and monitoring the progression of the acute scrotums, in additional to conventional Doppler sonography.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Accuracy of real-time shear wave elastography in staging hepatic fibrosis: a meta-analysis
    Fu, Juan
    Wu, Biao
    Wu, Huazhi
    Lin, Feng
    Deng, Wei
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [42] Real-Time Assessment of Myocardial Contractility Using Shear Wave Imaging
    Pernot, Mathieu
    Couade, Mathieu
    Mateo, Philippe
    Crozatier, Bertrand
    Fischmeister, Rodolphe
    Tanter, Mickael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (01) : 65 - 72
  • [43] Stiffness in breast masses with posterior acoustic shadowing: significance of ultrasound real time shear wave elastography
    Luo, Hui
    Li, Jian
    Shi, Yang
    Xiao, Xiaojun
    Wang, Yuanyang
    Wei, Zhanghong
    Xu, Jinfeng
    BMC MEDICAL IMAGING, 2022, 22 (01)
  • [44] Experimental study on monitoring microwave ablation efficacy by real-time shear wave elastography in ex vivo porcine brain
    Li, Rui
    Zhang, Yukang
    Cheng, Linggang
    Zheng, Shuai
    Li, Hongbing
    Zhang, Hongxia
    Du, Lijuan
    He, Wen
    Zhang, Wei
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2024, 41 (01)
  • [45] Stiffness of prostate gland measured by transrectal real-time shear wave elastography for detection of prostate cancer: a feasibility study
    Ji, Yonghao
    Ruan, Litao
    Ren, Wei
    Dun, Guoliang
    Liu, Jianxue
    Zhang, Yaoren
    Wan, Qinyun
    BRITISH JOURNAL OF RADIOLOGY, 2019, 92 (1097)
  • [46] Real-Time Shear Wave Ultrasound Elastography Differentiates Fibrotic from Inflammatory Strictures in Patients with Crohn's Disease
    Chen, Yu-jun
    Mao, Ren
    Li, Xue-hua
    Cao, Qing-hua
    Chen, Zhi-hui
    Liu, Bao-xian
    Chen, Shu-ling
    Chen, Bai-li
    He, Yao
    Zeng, Zhi-rong
    Ben-Horin, Shomron
    Rimola, Jordi
    Rieder, Florian
    Xie, Xiao-yan
    Chen, Min-hu
    INFLAMMATORY BOWEL DISEASES, 2018, 24 (10) : 2183 - 2190
  • [47] Comparisons among the Ultrasonography Prediction Model, Real-Time and Shear Wave Elastography in the Evaluation of Major Salivary Gland Tumors
    Cheng, Ping-Chia
    Lo, Wu-Chia
    Chang, Chih-Ming
    Wen, Ming-Hsun
    Cheng, Po-Wen
    Liao, Li-Jen
    DIAGNOSTICS, 2022, 12 (10)
  • [48] Real-time ultrasound elastography: an assessment of enlarged cervical lymph nodes
    Lo, Wu-Chia
    Cheng, Po-Wen
    Wang, Chi-Te
    Liao, Li-Jen
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2351 - 2357
  • [49] Impact of hemodialysis on liver stiffness measured with real-time two-dimensional shear wave elastography
    Puljiz, Danijela Zjacic
    Mestrovic, Antonio
    Zaja, Ivan
    Tonkic, Ante
    Grgurevic, Ivica
    Duplancic, Darko
    Jukic, Ivana Kristina Delic
    Ljutic, Dragan
    Puljiz, Zeljko
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (3-4) : 96 - 101
  • [50] Usefulness of real-time tissue elastography for detecting the border of basal cell carcinomas
    Tanaka, Takamitsu
    Tada, Yayoi
    Ohnishi, Takamitsu
    Watanabe, Shinichi
    JOURNAL OF DERMATOLOGY, 2017, 44 (04) : 438 - 443