Three-Dimensional Sonohysterography Compared With Vaginoscopic Hysteroscopy for Evaluation of the Uterine Cavity in Patients With Recurrent Implantation Failure in In Vitro Fertilization Cycles

被引:9
|
作者
Negm, Sherif M. M. [1 ]
Kamel, Rasha A. [1 ]
Abuhamila, Fouad A. [1 ]
机构
[1] Cairo Univ, Dept Obstet & Gynecol, Fac Med, Hayat Fertil & Womens Hlth Ctr, Cairo, Egypt
关键词
Three dimensional ultrasound; Sonohysterography; Vaginoscopic hysteroscopy; Recurrent implantation failure; in vitro fertilization; SALINE INFUSION SONOHYSTEROGRAPHY; OFFICE HYSTEROSCOPY; TRANSVAGINAL SONOGRAPHY; DIAGNOSTIC HYSTEROSCOPY; EMBRYO TRANSFER; WOMEN; HYSTEROSONOGRAPHY; MANAGEMENT; AGREEMENT; PAIN;
D O I
10.1016/j.jmig.2012.03.021
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To estimate the degree of agreement between 3-dimensional sonohysterography (3D-SHG) and vaginoscopic hysteroscopy (VH) in detection of uterine cavity abnormalities in patients with recurrent implantation failure in in vitro fertilization cycles. Design: Comparative observational cross-sectional study (Canadian Task Force classification II-1). Setting: Private assisted-conception unit. Patients: One hundred forty-three patients with a history of at least 2 previous implantation failures despite transfer of good quality embryos in assisted-conception cycles. Interventions: 3D-SHG was followed by VH. The Cohen kappa for interrater agreement was calculated for the level of agreement between the 2 diagnostic procedures. Procedure time in seconds was recorded for both procedures. Patients were asked to rate their degree of discomfort or pain during both procedures using a visual analog scale. Measurements and Main Results: There was a substantial degree of concordance between 3D-SHG and VH (kappa = 0.77; 95% confidence interval, 0.6-0.84). The median procedure time for 3D-SHG was 296 seconds (range, 231-327 seconds), and for VH was 315 seconds (range, 232-361 seconds), and the difference was statistically significant (p = .02). The visual analog scale pain scores also showed that 3D-SHG, with a median pain score of 2.1 (range, 1-3) was better tolerated than VH, with a median pain score of 2.9 (range, 2-4) (p < .001). Conclusion: Our results show that there is a substantial degree of concordance between 3D-SHG and VH in diagnosing uterine cavity anomalies. We also found that 3D-SHG took significantly less time and induced less patient discomfort than did VH. We recommend that 3D-SHG should be the method of first choice for outpatient evaluation of the uterine cavity. Journal of Minimally Invasive Gynecology (2012) 19, 503-508 (C) 2012 AAGL. All rights reserved.
引用
收藏
页码:503 / 508
页数:6
相关论文
共 32 条
  • [1] Observer agreement in the evaluation of the uterine cavity by hysteroscopy prior to in vitro fertilization
    Kasius, J. C.
    Broekmans, F. J. M.
    Veersema, S.
    Eijkemans, M. J. C.
    van Santbrink, E. J. P.
    Devroey, P.
    Fauser, B. C. J. M.
    Fatemi, H. M.
    HUMAN REPRODUCTION, 2011, 26 (04) : 801 - 807
  • [2] The Diagnostic Accuracy of Two- vs Three-Dimensional Sonohysterography for Evaluation of the Uterine Cavity in the Reproductive Age
    El-Sherbiny, Walid
    El-Mazny, Akmal
    Abou-Salem, Nermeen
    Mostafa, Wael Sayed
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2015, 22 (01) : 127 - 131
  • [3] The evaluation of uterine cavity with saline infusion sonohysterography and hysteroscopy in infertile patients
    Bartkowiak, Robert
    Kaminski, Pawel
    Wielgos, Miroslaw
    Bobrowska, Katarzyna
    NEUROENDOCRINOLOGY LETTERS, 2006, 27 (04) : 523 - 528
  • [4] Diagnostic accuracy of three-dimensional sonohysterography compared with office hysteroscopy and its interrater/intrarater agreement in uterine cavity assessment after hysteroscopic metroplasty
    Ludwin, Artur
    Ludwin, Inga
    Kudla, Marek
    Pitynski, Kazimierz
    Banas, Tomasz
    Jach, Robert
    Knafel, Anna
    FERTILITY AND STERILITY, 2014, 101 (05) : 1392 - U45
  • [5] Hysteroscopy as an investigation tool in recurrent implantation failure in vitro fertilization
    Al-Turki, Haifa A.
    SAUDI MEDICAL JOURNAL, 2018, 39 (03) : 243 - 246
  • [6] Effect of hysteroscopy before starting in-vitro fertilization for women with recurrent implantation failure A meta-analysis and systematic review
    Mao, Xiaoyan
    Wu, Ling
    Chen, Qiuju
    Kuang, Yanping
    Zhang, Shaozhen
    MEDICINE, 2019, 98 (07)
  • [7] Three-dimensional ultrasonographic reconstruction of the uterine cavity: toward virtual hysteroscopy?
    Ayoubi, JM
    Fanchin, R
    Ferretti, G
    Pons, JC
    Bricault, I
    EUROPEAN RADIOLOGY, 2002, 12 (08) : 2030 - 2033
  • [8] Comparative study on the role of diagnostic hysteroscopy in evaluation of the uterine cavity prior to in vitro fertilization in a developing country
    Bahadur, Anupama
    Malhotra, Neena
    Singh, Neeta
    Gurunath, Sumana
    Mittal, Suneeta
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2013, 288 (05) : 1137 - 1143
  • [9] Uterine cavity assessment in infertile women: Sensitivity and specificity of three-dimensional Hysterosonography versus Hysteroscopy
    Ahmadi, Firoozeh
    Rashidy, Zohreh
    Haghighi, Hadieh
    Akhoond, Mohamadreza
    Niknejadi, Maryam
    Hemat, Mandana
    ShamsiPour, Mansour
    IRANIAN JOURNAL OF REPRODUCTIVE MEDICINE, 2013, 11 (12) : 977 - 982
  • [10] Comparison of hysterosalpingography, hysterosonography and hysteroscopy in evaluation of the uterine cavity in patients with recurrent pregnancy losses
    Guimarães Filho H.A.
    Mattar R.
    Pires C.R.
    Araujo Jr. E.
    Moron A.F.
    Nardozza L.M.M.