Comparative study on induced macrocell corrosion phenomenon in repaired ordinary reinforced and self-compacting concrete structures

被引:5
|
作者
Wasim, M. [1 ]
Hussain, R. R. [1 ]
机构
[1] King Saud Univ, Dept Civil Engn, Coll Engn, Riyadh 11421, Saudi Arabia
关键词
Self-compacting concrete; Ordinary reinforced concrete; Chloride contamination; Reinforcing steel; Macrocell corrosion; Patch repair; RESISTANCE; STEEL;
D O I
10.1179/1743278213Y.0000000090
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper aimed at an experimental investigation of the comparative corrosion phenomenon in the reinforcing steel of repaired chloride contaminated self-compacting concrete (SCRC) and ordinary concrete (OC) patches. This research is a continuation of a previous study in which macrocell specimens were prepared with OC having different chloride contaminations simulating the actual patch repair in the construction field. Here, in this research, the same specimens were prepared with SCRC to investigate more deeply the macrocell phenomenon in SCRC, which received limited attention in the past. Four prismatic specimens with two sets of 5 and 3% chloride contaminated SCRC at the two ends were prepared respectively, and the middle portion of these specimens was cast after 24 h with uncontaminated SCRC simulating the actual patch repair in the field. After 1 year of experimental observations of corrosion potentials and corrosion rates, interesting and novel results were obtained in comparison with OC and SCRC specimens.
引用
收藏
页码:370 / 379
页数:10
相关论文
共 50 条
  • [31] Application of Self-Compacting Concrete in Strengthening of Existing Reinforced Concrete Column
    Yin, Xiaosan
    Zhai, Shifeng
    Gong, Tianniu
    NEW MATERIALS AND PROCESSES, PTS 1-3, 2012, 476-478 : 1722 - 1725
  • [32] Life cycle cost analysis of reinforced concrete structures cast with self-compacting concrete and normally vibrated concrete
    Sideris, K. K.
    Georgiadis, A.
    Anagnostopoulos, N.
    Manita, P.
    Skarlatos, E.
    CONCRETE SOLUTIONS, 2012, : 835 - 839
  • [33] Shrinkage of self-compacting concrete. A comparative analysis
    Oliveira, Miguel Jose
    Ribeiro, Antonio Bettencourt
    Branco, Fernando Garrido
    JOURNAL OF BUILDING ENGINEERING, 2017, 9 : 117 - 124
  • [34] Induced macro-cell corrosion phenomenon in the simulated repaired reinforced concrete patch
    Hussain, R.
    Wasim, M.
    Ishida, T.
    AUSTRALIAN JOURNAL OF CIVIL ENGINEERING, 2010, 8 (01) : 53 - 60
  • [35] Study on early age restrained shrinkage of fiber reinforced self-compacting concrete
    State Key Laboratory of Coastal and Offshore Engineering, Dalian University of Technology, Dalian 116024, China
    Jianzhu Cailiao Xuebao, 2008, 1 (8-13):
  • [36] Study of a self-compacting fiber-reinforced concrete to be applied in the precast industry
    Fernandes P.A.L.
    Veludo J.
    Almeida N.
    Baptista J.
    Rodrigues H.
    Innovative Infrastructure Solutions, 2018, 3 (1)
  • [37] Detailed study on flexural strength of polypropylene fiber reinforced self-compacting concrete
    Ramesh, B.
    Gokulnath, V
    Kumar, M. Ranjith
    MATERIALS TODAY-PROCEEDINGS, 2020, 22 : 1054 - 1058
  • [38] Structural performance of fiber reinforced lightweight self-compacting concrete beams subjected to accelerated corrosion
    Hossain, K. M. A.
    Hossain, M. A.
    Manzur, T.
    JOURNAL OF BUILDING ENGINEERING, 2020, 30
  • [39] Study of the flexural and shear toughness of steel fiber reinforced self-compacting concrete
    Ding, Yining
    Liu, Siguo
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2010, 43 (11): : 55 - 63
  • [40] Study on shear resistance of steel fiber reinforced self-compacting concrete beams
    Ding, Yi-Ning
    Liu, Ya-Jun
    Liu, Si-Guo
    Liu, He-Kai
    Shuili Xuebao/Journal of Hydraulic Engineering, 2011, 42 (04): : 461 - 468