European, Multicenter, Prospective, Non-comparative Clinical Evaluation of an Extended Depth of Focus Intraocular Lens

被引:24
作者
Auffarth, Gerd U. [1 ]
Moraru, Ozana [2 ]
Munteanu, Mihnea [3 ]
Tognetto, Daniele [4 ]
Bordin, Paolo [5 ]
Belucci, Roberto [6 ]
Khoramnia, Ramin [1 ]
Son, Hyeck-Soo [1 ]
机构
[1] Ruprecht Karls Univ Augenklin Heidelberg, D-69120 Heidelberg, Germany
[2] Oculus Eye Clin Bucharest, Bucharest, Romania
[3] Victor Babes Univ Med & Pharm, Prof Dr Munteanu Ophthalmol Ctr, Timisoara, Romania
[4] Azienda Sanitaria Univ Integrata Trieste Osped Ma, Clin Oculist, Trieste, Italy
[5] Osped Mater Salutis Legnago, Legnago, Italy
[6] Osped Borgo Trento, Univ Hosp Verona, Verona, Italy
关键词
READING PERFORMANCE; CONTRAST SENSITIVITY; PATIENT SATISFACTION; VISUAL OUTCOMES; VISION; IMPLANTATION; RANGE; MODELS; ARRAY;
D O I
10.3928/1081597X-20200603-01
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate clinical and safety results obtained with an extended depth of focus IEDOF) intraocular tens (IOL). METHODS: In this European, multicenter, prospective, uncontrolled, interventional study, 77 patients were enrolled in the study, 71 patients received bilateral implantation of the Mini Well Ready EDOF IOL (SIFI S.p.A.), and 68 patients completed the study and were evaluated 2 to 4 months postoperatively. Each clinical examination recorded uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVAI intermediate visual acuity, and uncorrected (UNVA), distance-corrected (DCNVA), and corrected (CNVA) near visual acuity. A defocus curve from +2.00 to -5.00 diopters (DI was obtained, contrast sensitivity and reading ability were assessed, and the perception of dysphotopsia was evaluated. RESULTS: Mean binocular visual results showed UDVA, UIVA, and UNVA values of -0.01 +/- 0.15, 0.03 +/- 0.10, and 0.10 +/- 0.11 logMAR, respectively. Mean binocular defocus curve demonstrated a visual acuity of 0.30 logMAR or better from +2.00 to -3.00 D. Mean photopic contrast sensitivity values were 1.86, 2.18, 1,97, 1.51, and 1.17 at 1.5, 3.0, 6.0, 12.0, and 18.0 cycles per degree, respectively. A fluent reading speed of 80 words per minute was reached at 0.5 logRAD by 95.31% of patients without distance correction. The mean halo size was 33.06 +/- 14.25, mean halo intensity was 38.00 +/- 18.51, mean glare size was 23.85 +/- 10.43, and mean glare intensity was 42.23 +/- 13.22. One postoperative complication, a moderate photophobia, was observed and classified as related to the tens. CONCLUSIONS: The Mini Well Ready EDOF IOL provides good visual acuity across various distances and functional reading ability provided at a near range, and delivers an enhanced contrast sensitivity white causing a tow incidence of photic phenomena.
引用
收藏
页码:426 / +
页数:14
相关论文
共 30 条
  • [1] Extended depth of focus intraocular lenses for presbyopia
    Akella, Sruti S.
    Juthani, Viral V.
    [J]. CURRENT OPINION IN OPHTHALMOLOGY, 2018, 29 (04) : 319 - 323
  • [2] Alba-Bueno F, 2014, Arch Soc Esp Oftalmol, V89, P397, DOI 10.1016/j.oftal.2014.01.002
  • [3] Postoperative bilateral reading performance with 4 intraocular lens models: Six-month results
    Alio, Jorge L.
    Grabner, Guenther
    Plaza-Puche, Ana B.
    Rasp, Max
    Pinero, David P.
    Seyeddain, Orang
    Rodriguez-Prats, Jose L.
    Jose Ayala, Maria
    Moreu, Rocio
    Hohensinn, Melchior
    Riha, Wolfgang
    Dexl, Alois
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (05) : 842 - 852
  • [4] Clinical Evaluation of an Extended Depth of Focus Intraocular Lens With the Salzburg Reading Desk
    Attia, Mary S. A.
    Auffarth, Gerd U.
    Kretz, Florian T. A.
    Tandogan, Tamer
    Rabsilber, Tanja M.
    Holzer, Mike P.
    Khoramnia, Ramin
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (10) : 664 - +
  • [5] Near and intermediate reading performance of a diffractive trifocal intraocular lens using a reading desk
    Attia, Mary S. A.
    Auffarth, Gerd U.
    Khoramnia, Ramin
    Linz, Katharina
    Kretz, Florian T. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12) : 2707 - 2714
  • [6] Multifocal versus monofocal intraocular lenses after cataract extraction
    Calladine, Daniel
    Evans, Jennifer R.
    Shah, Sweata
    Leyland, Martin
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (09):
  • [7] Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study
    Cochener, Beatrice
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (09) : 1268 - 1275
  • [8] Clinical Outcomes With a Trifocal Intraocular Lens: A Multicenter Study
    Cochener, Beatrice
    Vryghem, Jerome
    Rozot, Pascal
    Lesieur, Gilles
    Chevalier, Jean-Paul
    Henry, Jean-Marie
    David, Thierry
    Lesueur, Laurence
    Gatinel, Damien
    Ganem, Cati
    Blanckaert, Johan
    Van Acker, Emmanuel
    Heireman, Steven
    Ghekiere, Sofie
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (11) : 762 - 768
  • [9] Reading Performance After Implantation of a Modified Corneal Inlay Design for the Surgical Correction of Presbyopia: 1-Year Follow-up
    Dexl, Alois K.
    Seyeddain, Orang
    Riha, Wolfgang
    Hohensinn, Melchior
    Rueckl, Theresa
    Hitzl, Wolfgang
    Grabner, Guenther
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) : 994 - 1001
  • [10] Binocular and Monocular Implantation of Small-Aperture Intraocular Lenses in Cataract Surgery
    Dick, H. Burkhard
    Elling, Matthias
    Schultz, Tim
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2018, 34 (09) : 629 - +