Continuous Monitoring of Coordinated Cardiovascular Responses

被引:5
|
作者
Sola, Josep [1 ]
Chetelat, Olivier [1 ]
Luprano, Jean [1 ]
机构
[1] Swiss Ctr Elect & Microtechnol CSEM, CH-2002 Neuchatel, Switzerland
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
10.1109/IEMBS.2008.4649433
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The continuous separate monitoring of cardiac and vascular functions provide important insights on cardiovascular regulation. In the last years several attempts have failed at demonstrating the feasibility of using Pulse Wave Velocity as a surrogate indicator of arterial blood pressure. Upon the hypothesis that the cause of PWV unreliability is vasomotor activity, in this paper we develop an extended model of lumped arterial tree that copes with changes in vessels diameter. The benefit of this approach is twofold: on the one hand one might correct the effects of vasomotor activity on the estimation of arterial blood pressure on the basis of PWV, and on the other hand one obtains continuous non-invasive estimations of Cardiac Output and Total Peripheral Resistance.
引用
收藏
页码:1423 / 1426
页数:4
相关论文
共 50 条
  • [31] Adaptive responses of the cardiovascular system to prolonged spaceflight conditions: Assessment with Holter monitoring
    Baevsky, RM
    Bennett, BS
    Bungo, MW
    Charles, JB
    Goldberger, AL
    Nikulina, GA
    JOURNAL OF CARDIOVASCULAR DIAGNOSIS AND PROCEDURES, 1997, 14 (02): : 53 - 57
  • [32] INVASIVE MONITORING OF CARDIOVASCULAR-RESPONSES TO DYNAMIC AND STATIC TECHNIQUES SUPERIMPOSED ON THE TRUNK
    KEELAN, MH
    SOBUSH, DC
    KLOTH, L
    PHYSICAL THERAPY, 1986, 66 (05): : 779 - 779
  • [33] Learning coordinated behavior in a continuous environment
    Ono, N
    Fukuta, Y
    DISTRIBUTED ARTIFICIAL INTELLIGENCE MEETS MACHINE LEARNING: LEARNING IN MULTI-AGENT ENVIRONMENTS, 1997, 1221 : 73 - 81
  • [34] Discontinuous sets of knee extensions induce higher cardiovascular responses in comparison to continuous ones
    Polito, Marcos Doederlein
    Simao, Roberto
    Lira, Vitor Agnew
    Lucas da Nobrega, Antonio Claudio
    Veras Farinatti, Paulo de Tarso
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2008, 90 (06) : 382 - 387
  • [35] Continuous Monitoring of Health and Mobility Indicators in Patients with Cardiovascular Disease: A Review of Recent Technologies
    Shiwani, Muhammad Ali
    Chico, Timothy J. A.
    Ciravegna, Fabio
    Mihaylova, Lyudmila
    SENSORS, 2023, 23 (12)
  • [36] DYSVASCULAR AMPUTEE REHABILITATION - THE ROLE OF CONTINUOUS NONINVASIVE CARDIOVASCULAR MONITORING DURING PHYSICAL THERAPY
    ROTH, EJ
    WIESNER, SL
    GREEN, D
    WU, YC
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 1990, 69 (01) : 16 - 22
  • [37] A Flexible Pressure Sensor with Ink Printed Porous Graphene for Continuous Cardiovascular Status Monitoring
    Peng, Yuxin
    Zhou, Jingzhi
    Song, Xian
    Pang, Kai
    Samy, Akram
    Hao, Zengming
    Wang, Jian
    SENSORS, 2021, 21 (02) : 1 - 12
  • [38] ON CARDIOVASCULAR MONITORING
    STOKES, DN
    HUTTON, P
    BRITISH JOURNAL OF HOSPITAL MEDICINE, 1989, 41 (05) : 481 - 484
  • [39] Cardiovascular monitoring
    Quinn, T
    JOURNAL OF ADVANCED NURSING, 1998, 27 (03) : 666 - 666
  • [40] Mechanoadaptive Responses in the Periodontium Are Coordinated by Wnt
    Xu, Q.
    Yuan, X.
    Zhang, X.
    Chen, J.
    Shi, Y.
    Brunski, J. B.
    Helms, J. A.
    JOURNAL OF DENTAL RESEARCH, 2019, 98 (06) : 689 - 697