Summary on Calibration Method of Line-structured Light Sensor

被引:0
|
作者
Zhang, Xi [1 ]
Zhang, Jian [1 ]
机构
[1] Shanghai Univ, Sch Mechatron Engn & Automat, 149 Yanchang Rd, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional sensing; Line-structured light measurement; Calibration target; Light plane calibration; VISION SENSOR;
D O I
暂无
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Line-structured light sensor (LLS) can provide the capability of three-dimensional point acquisition for robotics. As one type of 3D scanners, LLS has been widely used in many filed of robotics for its strong anti-interference, fast scanning speed and high measuring accuracy. Researchers have been studying the methods to improve the accuracy, and the operability of the LLS for many years. In this paper, calibration methods for LLS are reviewed, which covers the calibration target and the light plane calibration methods. What's more, some potential improvements are discussed and analyzed. This review paper can be used as a reference guide for researchers to choose suitable calibration method and calibration target for developing an applicable LLS.
引用
收藏
页码:1142 / 1147
页数:6
相关论文
共 50 条
  • [1] Summary on Calibration Method of Line-Structured Light
    Xi, Zhang
    Jian, Zhang
    LASER & OPTOELECTRONICS PROGRESS, 2018, 55 (02)
  • [2] Calibration Method for Line-Structured Light
    Zhang Ruifeng
    Shu Ziyun
    Nan Ganglei
    LASER & OPTOELECTRONICS PROGRESS, 2019, 56 (22)
  • [3] Parallel-based calibration method for line-structured light vision sensor
    Wei, Zhenzhong
    Shao, Mingwei
    Zhang, Guangjun
    Wang, Yali
    OPTICAL ENGINEERING, 2014, 53 (03)
  • [4] Calibration method for line-structured light vision sensor based on a single ball target
    Liu, Zhen
    Li, Xiaojing
    Li, Fengjiao
    Zhang, Guangjun
    OPTICS AND LASERS IN ENGINEERING, 2015, 69 : 20 - 28
  • [5] Calibration method for a line-structured light vision sensor based on a single cylindrical target
    Zhu, Zhenmin
    Wang, Xinyun
    Zhou, Fuqiang
    Cen, Yigang
    APPLIED OPTICS, 2020, 59 (05) : 1376 - 1382
  • [6] Calibration method for line-structured light multi-vision sensor based on combined target
    Yin-guo Huang
    Xing-hua Li
    Pei-fen Chen
    EURASIP Journal on Wireless Communications and Networking, 2013
  • [7] Calibration method for line-structured light multi-vision sensor based on combined target
    Huang, Yin-guo
    Li, Xing-hua
    Chen, Pei-fen
    EURASIP JOURNAL ON WIRELESS COMMUNICATIONS AND NETWORKING, 2013,
  • [8] Research on calibration method for line-structured light sensor based on spatial quadratic surface fitting
    Zhu, Linwei
    Cheng, Xiaoqi
    Li, Xiaosong
    Tan, Haishu
    Chen, Hujun
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2025, 36 (01)
  • [9] Dental caries location with line-structured light and integrated calibration method
    Chen, Li
    Zhou, Zhehai
    Hu, Guoqing
    Li, Yinglong
    Qin, Ying
    Li, Dong
    Li, Zhongxiang
    Zan, Huixin
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS XIII, 2023, 12770
  • [10] Flexible calibration method for line-structured light based on binocular vision
    Zhu, Ye
    Wang, Lianpo
    Gu, Yonggang
    Zhai, Chao
    Jin, Yi
    AOPC 2017: 3D MEASUREMENT TECHNOLOGY FOR INTELLIGENT MANUFACTURING, 2017, 10458