TSC of HTV Silicone Rubber during Corona Deterioration

被引:1
作者
Liang, Ying [1 ,2 ]
Ding, Lijian [1 ,2 ]
Li, C. R. [1 ,2 ]
Tu, Youping [1 ,2 ]
Yang, Kun [1 ,2 ]
机构
[1] North China Elect Power Univ, Beijing Key Lab High Voltage, Beijing 102206, Peoples R China
[2] North China Elect Power Univ, EMC, Beijing 102206, Peoples R China
来源
2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2 | 2007年
关键词
D O I
10.1109/ICSD.2007.4290766
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to investigate the micro-electric characteristics of HTV silicone rubber during corona deterioration, the corona accelerating deterioration was conducted and the thermal stimulation current (TSC) was measured for HTV silicone rubber samples at different deterioration stage. Experimental results show that the TSC curves were changed gradually with different corona deterioration procedure. There are trend to move the current peak from a relatively low temperature to a high temperature, and the trapped charges increase with the increase of corona discharge time. Considering the calculated trap parameters, it is confirmed that not only more traps are produced by corona deterioration processing, but the trap energy levels are gradually improved by corona deterioration procedure.
引用
收藏
页码:114 / +
页数:2
相关论文
共 12 条
  • [1] BOGNAR A, 1997, 10 ISH MONTR, P325
  • [2] Chen R., 1981, ANAL THERMALLY STIMU
  • [3] AGING IN SILICONE-RUBBER USED FOR OUTDOOR INSULATION
    GORUR, RS
    KARADY, GG
    JAGOTA, A
    SHAH, M
    YATES, AM
    SCHNEIDER, HM
    DETOURREIL, C
    MACKEVICH, JP
    HOFFMAN, JW
    ORBECK, T
    AMBURGEY, G
    ROKOS, G
    TOSKEY, GA
    MUELLER, PR
    TAY, R
    WINTER, HJ
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (02) : 525 - 538
  • [4] KINDERSBERGER J, 1995, 9 ISH GRAZ, P1
  • [5] KOSHINO Y, 1998, ANN REP C EL INS DIE, V1, P72
  • [6] Impact of corona on the long-term performance of nonceramic insulators
    Moreno, VM
    Gorur, RS
    Kroese, A
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2003, 10 (01) : 80 - 95
  • [7] Aging of non-ceramic insulators due to corona from water drops
    Phillips, AJ
    Childs, DJ
    Schneider, HM
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1999, 14 (03) : 1081 - 1089
  • [8] REYNDEN SM, 1997, CIGRE REG M AFR CONT
  • [9] Review of aging and recovery of silicone rubber insulation for outdoor use
    Reynders, JP
    Jandrell, IR
    Reynders, SM
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 1999, 6 (05) : 620 - 631
  • [10] REYNDERS SM, 1997, 10 ISH, P121