X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

被引:22
作者
Vedantham, Srinivasan [1 ]
Karellas, Andrew [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
基金
美国国家卫生研究院;
关键词
phase contrast; interferometry; refraction; diffraction; mammography; phantom; SUBSTITUTE MATERIALS; DIGITAL MAMMOGRAPHY; TOMOGRAPHY; CT; RADIOGRAPHS; FORMULATION; PHOTON;
D O I
10.1118/1.4794503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n = 1 - delta + i beta. The real part of the refractive index, specifically the refractive index decrement (delta), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine delta. At each x-ray photon energy, the absolute percent difference in delta between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient mu, and hence delta, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the delta of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the mu of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the delta of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of mu. Polymethyl methacrylate, a commonly used tissue substitute, exhibited delta greater than fibroglandular tissue by similar to 12%. The A-150 plastic closely approximated the skin. Several materials exhibited delta between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between delta and mu for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the delta and mu of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited delta greater than calcium hydroxyapatite by similar to 23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4794503]
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Quantitative Analysis of Contrast to Noise Ratio Using a Phase Contrast X-ray Imaging Prototype
    Ghani, Muhammad U.
    Wu, Di
    Li, Yuhua
    Kang, Minhua
    Chen, Wei R.
    Wu, Xizeng
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES VIII, 2013, 8582
  • [42] High-Resolution X-Ray Phase-Contrast 3-D Imaging of Breast Tissue Specimens as a Possible Adjunct to Histopathology
    Baran, Patrycja
    Mayo, Sheridan
    McCormack, Mikkaela
    Pacile, Serena
    Tromba, Giuliana
    Dullin, Christian
    Zanconati, Fabrizio
    Arfelli, Fulvia
    Dreossi, Diego
    Fox, Jane
    Prodanovic, Zdenka
    Cholewa, Marian
    Quiney, Harry
    Dimmock, Matthew
    Nesterets, Yakov
    Thompson, Darren
    Brennan, Patrick
    Gureyev, Timur
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2018, 37 (12) : 2642 - 2650
  • [43] Measurements of imaging parameters of a phase contrast x-ray imaging prototype
    Li, Yuhua
    Rong, John
    Chu, Robert Y. L.
    Zhang, Da
    Archer, Ann
    Fajardo, Laurie
    Chen, Wei R.
    Wu, Xizeng
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES III, 2008, 6857
  • [44] Preliminary demonstration of flexible dual-energy x-ray phase-contrast imaging
    Wang, Shenghao
    Zan, Guibin
    Wang, Qiuping
    Liu, Shijie
    OPTICAL ENGINEERING, 2019, 58 (11)
  • [45] An integral phase contrast modulation transfer function for X-ray phase contrast imaging
    Wu, Jie
    Chen, Jiabi
    OPTIK, 2013, 124 (17): : 2583 - 2586
  • [46] X-ray Phase-Contrast Computed Tomography for Soft Tissue Imaging at the Imaging and Medical Beamline (IMBL) of the Australian Synchrotron
    Arhatari, Benedicta D.
    Stevenson, Andrew W.
    Abbey, Brian
    Nesterets, Yakov I.
    Maksimenko, Anton
    Hall, Christopher J.
    Thompson, Darren
    Mayo, Sheridan C.
    Fiala, Tom
    Quiney, Harry M.
    Taba, Seyedamir T.
    Lewis, Sarah J.
    Brennan, Patrick C.
    Dimmock, Matthew
    Hausermann, Daniel
    Gureyev, Timur E.
    APPLIED SCIENCES-BASEL, 2021, 11 (09):
  • [47] Crystal analyser-based X-ray phase contrast imaging in the dark field: implementation and evaluation using excised tissue specimens
    Ando, Masami
    Sunaguchi, Naoki
    Wu, Yanlin
    Synho Do
    Sung, Yongjin
    Louissaint, Abner
    Yuasa, Tetsuya
    Ichihara, Shu
    Gupta, Rajiv
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 423 - 433
  • [48] Simulation tools for analyzer-based X-ray phase contrast imaging system with a conventional X-ray source
    Caudevilla, Oriol
    Zhou, Wei
    Stoupin, Stanislav
    Verman, Boris
    Brankov, J. G.
    ADVANCES IN LABORATORY-BASED X-RAY SOURCES, OPTICS, AND APPLICATIONS V, 2016, 9964
  • [49] X-ray Phase Contrast Imaging of Calcified Tissue and Biomaterial Structure in Bioreactor Engineered Tissues
    Appel, Alyssa A.
    Larson, Jeffery C.
    Garson, Alfred B., III
    Guan, Huifeng
    Zhong, Zhong
    Nguyen, Bao-Ngoc B.
    Fisher, John P.
    Anastasio, Mark A.
    Brey, Eric M.
    BIOTECHNOLOGY AND BIOENGINEERING, 2015, 112 (03) : 612 - 620
  • [50] Evaluation of a new reconstruction algorithm for X-ray phase-contrast imaging
    Seifert, Maria
    Hauke, Christian
    Horn, Florian
    Lachner, Sebastian
    Ludwig, Veronika
    Pelzer, Georg
    Rieger, Jens
    Schuster, Max
    Wandner, Johannes
    Wolf, Andreas
    Michel, Thilo
    Anton, Gisela
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783