X-ray phase contrast imaging of the breast: Analysis of tissue simulating materials

被引:22
|
作者
Vedantham, Srinivasan [1 ]
Karellas, Andrew [1 ]
机构
[1] Univ Massachusetts, Sch Med, Dept Radiol, Worcester, MA 01655 USA
基金
美国国家卫生研究院;
关键词
phase contrast; interferometry; refraction; diffraction; mammography; phantom; SUBSTITUTE MATERIALS; DIGITAL MAMMOGRAPHY; TOMOGRAPHY; CT; RADIOGRAPHS; FORMULATION; PHOTON;
D O I
10.1118/1.4794503
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representative of breast tissues. Methods: Elemental compositions of breast tissues including adipose, fibroglandular, and skin were used to determine the refractive index, n = 1 - delta + i beta. The real part of the refractive index, specifically the refractive index decrement (delta), over the energy range of 5-50 keV were determined using XOP software (version 2.3, European Synchrotron Radiation Facility, France). Calcium oxalate and calcium hydroxyapatite were considered to represent the material compositions of microcalcifications in vivo. Nineteen tissue substitutes were considered as possible candidates to represent adipose tissue, fibroglandular tissue and skin, and four phantom materials were considered as possible candidates to represent microcalcifications. For each material, either the molecular formula, if available, or the elemental composition based on weight fraction, was used to determine delta. At each x-ray photon energy, the absolute percent difference in delta between the breast tissue and the substitute material was determined, from which three candidates were selected. From these candidate tissue substitutes, the material that minimized the absolute percent difference in linear attenuation coefficient mu, and hence delta, was considered to be best representative of that breast tissue. Results: Over the energy range of 5-50 keV, while the delta of CB3 and fibroglandular tissue-equivalent material were within 1% of that of fibroglandular tissue, the mu of fibroglandular tissue-equivalent material better approximated the fibroglandular tissue. While the delta of BR10 and adipose tissue-equivalent material were within 1% of that of adipose tissue, the tissue-equivalent material better approximated the adipose tissue in terms of mu. Polymethyl methacrylate, a commonly used tissue substitute, exhibited delta greater than fibroglandular tissue by similar to 12%. The A-150 plastic closely approximated the skin. Several materials exhibited delta between that of adipose and fibroglandular tissue. However, there was an energy-dependent mismatch in terms of equivalent fibroglandular weight fraction between delta and mu for these materials. For microcalcifications, aluminum and calcium carbonate were observed to straddle the delta and mu of calcium oxalate and calcium hydroxyapatite. Aluminum oxide, commonly used to represent microcalcifications in the American College of Radiology recommended phantoms for accreditation exhibited delta greater than calcium hydroxyapatite by similar to 23%. Conclusions: A breast phantom comprising A-150 plastic to represent the skin, commercially available adipose and fibroglandular tissue-equivalent formulations to represent adipose and fibroglandular tissue, respectively, was found to be best suited for x-ray phase-sensitive imaging of the breast. Calcium carbonate or aluminum can be used to represent microcalcifications. (C) 2013 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4794503]
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Novel Physical Heterogeneous Breast Phantom for X-Ray Phase Contrast Imaging
    Daskalaki, A.
    Malliori, A.
    Dermitzakis, A.
    Pallikarakis, N.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, CMBEBIH 2019, 2020, 73 : 105 - 110
  • [22] Motionless phase stepping in X-ray phase contrast imaging with a compact source
    Miao, Houxun
    Chen, Lei
    Bennett, Eric E.
    Adamo, Nick M.
    Gomella, Andrew A.
    DeLuca, Alexa M.
    Patel, Ajay
    Morgan, Nicole Y.
    Wen, Han
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (48) : 19268 - 19272
  • [23] Robustness of phase retrieval methods in x-ray phase contrast imaging: A comparison
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    MEDICAL PHYSICS, 2011, 38 (09) : 5073 - 5080
  • [24] Simulation and measurement of grating-based X-ray phase-contrast imaging
    Bartl, P.
    Bayer, F.
    Durst, J.
    Haas, W.
    Michel, T.
    Pelzer, G.
    Ritter, A.
    Weber, T.
    Anton, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S269 - S272
  • [25] The characterization of a phase contrast x-ray imaging prototype
    Donovan, Molly
    Zhang, Da
    Chen, Wei R.
    Liu, Hong
    COMPLEX DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IV, 2007, 6436
  • [26] Benchtop phase-contrast X-ray imaging
    Gundogdu, O.
    Nirgianaki, E.
    Ismail, E. Che
    Jenneson, P. M.
    Bradley, D. A.
    APPLIED RADIATION AND ISOTOPES, 2007, 65 (12) : 1337 - 1344
  • [27] Potential of Phase Contrast X-ray Imaging for detecting tumors in dense breast: Initial phantom studies
    Omoumi, Farid H.
    Wu, Di
    Guo, Yuran
    Ghani, Muhammad U.
    Li, Yuhua
    Boyce, Kari E.
    Liu, Hong
    BIOPHOTONICS AND IMMUNE RESPONSES XIII, 2018, 10495
  • [28] Hard X-ray phase-contrast imaging
    Gao, DC
    Pogany, A
    Stevenson, AW
    Gureyev, T
    Wilkins, SW
    Mai, ZH
    ACTA PHYSICA SINICA, 2000, 49 (12) : 2357 - 2368
  • [29] Optimization of propagation-based x-ray phase-contrast tomography for breast cancer imaging
    Baran, P.
    Pacile, S.
    Nesterets, Y. I.
    Mayo, S. C.
    Dullin, C.
    Dreossi, D.
    Arfelli, F.
    Thompson, D.
    Lockie, D.
    McCormack, M.
    Taba, S. T.
    Brun, F.
    Pinamonti, M.
    Nickson, C.
    Hall, C.
    Dimmock, M.
    Zanconati, F.
    Cholewa, M.
    Quiney, H.
    Brennan, P. C.
    Tromba, G.
    Gureyev, T. E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2315 - 2332
  • [30] Phase dispersion X-ray imaging of murine soft tissue
    Ingal, V. N.
    Ingal, E. A.
    CRYSTALLOGRAPHY REPORTS, 2013, 58 (07) : 1002 - 1009