摘要
To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses. One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54 +/- 9.94 years, range 21-88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared. Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone. Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone. aEuro cent SWE offers new information over and above conventional breast ultrasound aEuro cent Various SWE parameters were explored regarding distinction between benign and malignant lesions aEuro cent An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses aEuro cent However, ultrasound plus SWE was not significantly better than conventional ultrasound alone.
引用
收藏
页码:1803 / 1811
页数:9
相关论文
共 50 条
  • [1] Diagnostic performances of shear wave elastography: which parameter to use in differential diagnosis of solid breast masses?
    Eun Jung Lee
    Hae Kyoung Jung
    Kyung Hee Ko
    Jong Tae Lee
    Jung Hyun Yoon
    European Radiology, 2013, 23 : 1803 - 1811
  • [2] Diagnostic Performance of Quantitative Shear Wave Elastography in the Evaluation of Solid Breast Masses: Determination of the Most Discriminatory Parameter
    Au, Frederick Wing-Fa
    Ghai, Sandeep
    Moshonov, Hadas
    Kahn, Harriette
    Brennan, Cressida
    Dua, Hemi
    Crystal, Pavel
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2014, 203 (03) : W328 - W336
  • [3] Clinical Application of Shear Wave Elastography in Breast Masses
    Chang, Jin Young
    Moon, Jin Hee
    Koh, Sung Hye
    Park, Sun-Young
    Lee, Kwan Seop
    IRANIAN JOURNAL OF RADIOLOGY, 2017, 14 (01)
  • [4] Shear-wave elastography in the diagnosis of solid breast masses: what leads to false-negative or false-positive results?
    Yoon, Jung Hyun
    Jung, Hae Kyoung
    Lee, Jong Tae
    Ko, Kyung Hee
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2432 - 2440
  • [5] Pattern classification of ShearWave™ Elastography images for differential diagnosis between benign and malignant solid breast masses
    Tozaki, Mitsuhiro
    Fukuma, Eisuke
    ACTA RADIOLOGICA, 2011, 52 (10) : 1069 - 1075
  • [6] Differentiating solid breast masses: comparison of the diagnostic efficacy of shear wave elastography and magnetic resonance imaging
    Farghadani, Maryam
    Barikbin, Rozbeh
    Rezaei, Mostafa Haji
    Hekmatnia, Ali
    Aalinezhad, Marzieh
    Zare, Hosein
    DIAGNOSIS, 2021, 8 (03) : 382 - 387
  • [7] Visually assessed colour overlay features in shear-wave elastography for breast masses: quantification and diagnostic performance
    Gweon, Hye Mi
    Youk, Ji Hyun
    Son, Eun Ju
    Kim, Jeong-Ah
    EUROPEAN RADIOLOGY, 2013, 23 (03) : 658 - 663
  • [8] Performance of Shear Wave Elastography for Differentiation of Benign and Malignant Solid Breast Masses
    Li, Guiling
    Li, De-Wei
    Fang, Yu-Xiao
    Song, Yi-Jiang
    Deng, Zhu-Jun
    Gao, Jian
    Xie, Yan
    Yin, Tian-Sheng
    Ying, Li
    Tang, Kai-Fu
    PLOS ONE, 2013, 8 (10):
  • [9] Clinical application of qualitative assessment for breast masses in shear-wave elastography
    Gweon, Hye Mi
    Youk, Ji Hyun
    Son, Eun Ju
    Kim, Jeong-Ah
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E680 - E685
  • [10] Diagnostic performances of shear-wave elastography for identification of malignant breast lesions: a meta-analysis
    Chen, Limin
    He, Jun
    Liu, Gang
    Shao, Kezhong
    Zhou, Minda
    Li, Beilei
    Chen, Xiaofei
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (10) : 592 - 599