Fabricating optical fiber imaging sensors using inkjet printing technology: A pH sensor proof-of-concept

被引:41
作者
Carter, JC
Alvis, RM
Brown, SB
Langry, KC
Wilson, TS
McBride, MT
Myrick, ML
Cox, WR
Grove, ME
Colston, BW
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Univ S Carolina, Dept Chem & Biochem, Columbia, SC 29208 USA
[3] Microfab Technol Inc, Plano, TX 75074 USA
关键词
optical fiber; image guide; pH sensor; imaging; biosensor; microjet; inkjet; microdot;
D O I
10.1016/j.bios.2005.06.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We demonstrate the feasibility of using Drop-on-Demand microjet printing technology for fabricating imaging sensors by reproducibly printing an array of photopolymerizable sensing elements, containing a pH sensitive indicator, on the surface of an optical fiber image guide. The reproducibility of the microjet printing process is excellent for microdot (i.e. micrometer-sized polymer) sensor diameter (92.2 +/- 2.2 mu m), height (35.0 +/- 1.0 mu m), and roundness (0.00072 +/- 0.00023). pH sensors were evaluated in terms of pH sensing ability (<= 2% sensor variation), response time, and hysteresis using a custom fluorescence imaging system. In addition, the microjet technique has distinct advantages over other fabrication methods, which are discussed in detail. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:1359 / 1364
页数:6
相关论文
共 20 条
[11]   PHYSIOLOGICAL PH FIBEROPTIC CHEMICAL SENSOR BASED ON ENERGY-TRANSFER [J].
JORDAN, DM ;
WALT, DR ;
MILANOVICH, FP .
ANALYTICAL CHEMISTRY, 1987, 59 (03) :437-439
[12]   POLYMER MODIFICATION OF FIBER OPTIC CHEMICAL SENSORS AS A METHOD OF ENHANCING FLUORESCENCE SIGNAL FOR PH MEASUREMENT [J].
MUNKHOLM, C ;
WALT, DR ;
MILANOVICH, FP ;
KLAINER, SM .
ANALYTICAL CHEMISTRY, 1986, 58 (07) :1427-1430
[13]   A fiber-optic pH sensor prepared using a base-catalyzed organo-silica sol-gel [J].
Nivens, DA ;
Zhang, YK ;
Angel, SM .
ANALYTICA CHIMICA ACTA, 1998, 376 (02) :235-245
[14]   Multilayer sol-gel membranes for optical sensing applications:: single layer pH and dual layer CO2 and NH3 sensors [J].
Nivens, DA ;
Schiza, MV ;
Angel, SM .
TALANTA, 2002, 58 (03) :543-550
[15]   FIBER OPTIC PH PROBE FOR PHYSIOLOGICAL USE [J].
PETERSON, JI ;
GOLDSTEIN, SR ;
FITZGERALD, RV ;
BUCKHOLD, DK .
ANALYTICAL CHEMISTRY, 1980, 52 (06) :864-869
[16]   PH SENSOR BASED ON IMMOBILIZED FLUORESCEINAMINE [J].
SAARI, LA ;
SEITZ, WR .
ANALYTICAL CHEMISTRY, 1982, 54 (04) :821-823
[17]   Use of a 2D to 1D dimension reduction fiber-optic array for multiwavelength imaging sensors [J].
Schiza, MV ;
Nelson, MP ;
Myrick, ML ;
Angel, SM .
APPLIED SPECTROSCOPY, 2001, 55 (02) :217-226
[18]  
Wallace DB, 2002, DIRECT WRITE TECHNOL
[19]  
WOLFBEIS OS, 1991, FIBER OPTIC CHEM SEN, V1, P77
[20]   A FLUORESCENCE SENSOR FOR QUANTIFYING PH IN THE RANGE FROM 6.5 TO 8.5 [J].
ZHUJUN, Z ;
SEITZ, WR .
ANALYTICA CHIMICA ACTA, 1984, 160 (JUN) :47-55