Flexible X-ray Detector for Automatic Exposure Control in Digital Radiography

被引:10
作者
Oh, Kyungmin [1 ,2 ]
Han, Moojae [1 ]
Kim, Jinseon [1 ]
Heo, Yeji [1 ]
Kim, Kyotae [1 ]
Cho, Gyuseok [5 ]
Song, Yongkeun [5 ]
Cho, Sungho [5 ]
Heo, Seunguk [5 ]
Kim, Jinyoung [4 ]
Park, Sungkwang [3 ]
Nam, Sanghee [1 ]
机构
[1] Inje Univ, Dept Biomed Engn, Gimhae 621749, South Korea
[2] Korea Atom Energy Res Inst, Radiat Equipment Res Div, Daejeon 56212, South Korea
[3] Busan Paik Hosp, Radiat Oncol, Busan 614735, South Korea
[4] Haeundae Paik Hosp, Radiat Oncol, Busan 143729, South Korea
[5] Korea Inst Radiol & Med Sci, Heavy Ion Clin Res, Seoul 139240, South Korea
基金
新加坡国家研究基金会;
关键词
Automatic Exposure Controllers; Photoconductive Nanoparticles; Radiation Detectors; COMPUTED RADIOGRAPHY; SYSTEMS;
D O I
10.1166/jnn.2016.13533
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Automatic Exposure Controllers (AEC), currently used in diagnostic radiation imaging, reduce the rate of re-imaging by controlling the radiation exposure in the image acquisition areas while obtaining optimal diagnostic image. Among several types of AEC chamber, ionization chamber and solid state detector are commonly used. Especially, solid state detector makes AEC chamber be thin by minimizing the thickness to below 3 mm and show superior performance in application requiring high field signal during low X-ray energy exposure around 40 keV. However, commercially used solid state detector made of silicon diode suffer from ineffective performance changes due to doping variations and mechanically fragile property. In this study, solid state detectors made of compound photoconductive nanoparticles were introduced to detect X-ray signals. Three kinds of detectors were fabricated by depositing HgI2 with 14 mu m thickness, PbI2 with 11 mu m thickness, and PbO with 14 mu m thickness photoconductive layers using a screen printing method. X-ray linearity, reproducibility, transmittance, and energy dependence, and bending tests performed using these detectors yielded results close to current AEC chambers. In addition, from the result of bending test, the detector fabricated by the particle in binder method showed mechanically uncrushable and stable properties due to flexible property of binder material. These results point to the feasibility of photoconductor-based AEC chambers in the fields of diagnostic radiation and other areas.
引用
收藏
页码:11473 / 11476
页数:4
相关论文
共 10 条
[1]  
Bor D, 2008, DIAGN INTERV RADIOL, V14, P122
[2]   Calibrating automatic exposure control devices for digital radiography [J].
Doyle, P. ;
Martin, C. J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (21) :5475-5485
[3]   Optimising automatic exposure control in computed radiography and the impact on patient dose [J].
Doyle, P ;
Gentle, D ;
Martin, CJ .
RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) :236-239
[4]   Automatic exposure control for a slot scanning full field digital mammography system [J].
Elbakri, DA ;
Lakshminarayanan, AV ;
Tesic, MM .
MEDICAL PHYSICS, 2005, 32 (09) :2763-2770
[5]   Automatic Exposure Control Systems Designed to Maintain Constant Image Noise: Effects on Computed Tomography Dose and Noise Relative to Clinically Accepted Technique Charts [J].
Favazza, Christopher P. ;
Yu, Lifeng ;
Leng, Shuai ;
Kofler, James M. ;
McCollough, Cynthia H. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (03) :437-442
[6]   Radiation damage effects in Si materials and detectors and rad-hard Si detectors for SLHC [J].
Li, Z. .
JOURNAL OF INSTRUMENTATION, 2009, 4
[7]   AEC set-up optimisation with computed radiography imaging [J].
Mazzocchi, S ;
Belli, G ;
Busoni, S ;
Gori, C ;
Menchi, I ;
Salucci, P ;
Taddeucci, A ;
Zatelli, G .
RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) :169-173
[8]   A Comprehensive Review of Semiconductor Ultraviolet Photodetectors: From Thin Film to One-Dimensional Nanostructures [J].
Sang, Liwen ;
Liao, Meiyong ;
Sumiya, Masatomo .
SENSORS, 2013, 13 (08) :10482-10518
[9]   Quality assurance of computed and digital radiography systems [J].
Walsh, C. ;
Gorman, D. ;
Byrne, P. ;
Larkin, A. ;
Dowling, A. ;
Malone, J. F. .
RADIATION PROTECTION DOSIMETRY, 2008, 129 (1-3) :271-275
[10]   Effects of the automatic exposure compensation on the proximal caries diagnosis [J].
Yoshiura, K ;
Nakayama, E ;
Shimizu, M ;
Goto, TK ;
Chikui, T ;
Kawazu, T ;
Okamura, K .
DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (03) :140-144