Analysis of Aeolian Vibrations of Transmission Line Conductors and Extraction of Damper Optimal Placement with a Comprehensive Methodology

被引:5
|
作者
Rezaei, A. [1 ]
Sadeghi, M. H. [1 ]
机构
[1] Univ Tabriz, Dept Mech Engn, Tabriz, Iran
来源
INTERNATIONAL JOURNAL OF ENGINEERING | 2019年 / 32卷 / 02期
关键词
Aeolian Vibration; Transmission Line; Energy Balance Method; Stock-bridge Damper; Optimum Location; WIND-EXCITED VIBRATIONS; COMPUTATION; MODEL;
D O I
10.5829/ije.2019.32.02b.19
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Energy balance method is an effective and simple method which is used in the amplitude calculation of Aeolian vibration in transmission lines with Stockbridge damper. However, the accuracy of the results obtained by this method, heavily depends on the assumed mode shapes of the conductor vibration. In this study, by considering an appropriate model for the conductor vibration, a comprehensive methodology is presented to calculate the steady-state vibration amplitude of a conductor with arbitrary number of dampers. In this proposed method, the effects of traveling waves, variations of amplitude and phase, boundary conditions (finite length of the conductor), as well as the effect of number, location and impedance of the dampers are taken into account. Natural frequencies, damping rates and complex mode shapes are also obtained from forming and solving the nonlinear eigenvalue problem. Using this method, the effects of the damper placement on the vibration amplitude and bending strain are examined to achieve an optimum damper location. The comparison of the obtained values shows that considering the above parameters has a significant effect on the accuracy of the results.
引用
收藏
页码:328 / 337
页数:10
相关论文
共 50 条
  • [31] The optimal TADAS damper placement in moment resisting steel structures based on a cost-benefit analysis
    Yousefzadeh, A.
    Sebt, M. H.
    Tehranizadeh, M.
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2011, 9 (01) : 23 - 32
  • [32] Tuned-Mass-Damper-Inerter Performance Evaluation and Optimal Design for Transmission Line under Harmonic Excitation
    Liu, Xinpeng
    Yang, Yingwen
    Sun, Yi
    Zhong, Yongli
    Zhou, Lei
    Li, Siyuan
    Wu, Chaoyue
    BUILDINGS, 2022, 12 (04)
  • [33] Study and Analysis of HTLS Conductors for Increasing the Thermal Loading of 220 kV Transmission Line
    Kachhadiya, Akshit
    Sheth, Chetan
    Gupta, Vinod
    Darji, Krunal
    ADVANCES IN ELECTRIC POWER AND ENERGY INFRASTRUCTURE, 2020, 608 : 229 - 238
  • [34] Analysis on Selecting Application of Energy-Saving Conductors in Overhead Transmission Line Construction
    Bingran, Shao
    Jin, Liu
    Yingmin, Feng
    Guangsheng, Cui
    Bo, Yan
    Guoqi, Ren
    2016 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2016,
  • [35] Comprehensive analysis for conductor galloping of overhead transmission line and preventive measures
    Huang Jingya Central China Electric Power Testing and Research Institute
    Electricity, 1992, (04) : 45 - 50
  • [36] Optimal design and stress analysis of the transmission line inspection robot along the ground line
    Wang Haitao
    Yan Biwu
    Pu Ziheng
    Xiong Yuyao
    Fan Qiang
    Li Jian
    Zheng Lei
    JOURNAL OF ENGINEERING-JOE, 2019, (16): : 3088 - 3091
  • [37] Transmission Line Efficiency Improvement and Congestion Management under Critical Contingency Condition by Optimal Placement of TCSC
    Choudekar, Pallavi
    Sinha, S. K.
    Siddiqui, Anwar
    2016 7TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2016,
  • [38] Optimal placement of UPFC across a transmission line considering techno-economic aspects with physical limitation
    Das, Sourav
    Shegaonkar, Mayuree
    Gupta, Mrityunjay
    Acharjee, Parimal
    2017 7TH INTERNATIONAL SYMPOSIUM ON EMBEDDED COMPUTING AND SYSTEM DESIGN (ISED), 2017,
  • [39] Analysis of a shielded transmission line containing circular cylindrical conductors and coplanar lines on a grounded shield