Comparison of central and peripheral corneal thickness measurements with scanning-slit, Scheimpflug and Fourier-domain ocular coherence tomography

被引:27
作者
Randleman, J. Bradley [1 ,2 ]
Lynn, Michael J. [3 ]
Perez-Straziota, Claudia E. [1 ]
Weissman, Heather M. [1 ]
Kim, Sang Woo [4 ]
机构
[1] Emory Univ, Dept Ophthalmol, Atlanta, GA 30322 USA
[2] Emory Eye Ctr, Emory Vis, Atlanta, GA 30342 USA
[3] Emory Univ, Dept Biostat & Bioinformat, Rollins Sch Publ Hlth, Atlanta, GA 30322 USA
[4] Univ Ulsan, Coll Med, Dept Ophthalmol, Ulsan 680749, South Korea
关键词
Cornea; Diagnostic tests; Investigation; Imaging; Treatment Lasers; ANTERIOR-CHAMBER DEPTH; IN-SITU KERATOMILEUSIS; REFRACTIVE SURGERY; KERATOCONUS DIAGNOSIS; ULTRASONIC PACHYMETRY; ORBSCAN-II; PENTACAM; DEVICES; TOPOGRAPHY; PARAMETERS;
D O I
10.1136/bjophthalmol-2014-306340
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare central, regional and relational corneal thickness values obtained with multiple technologies in normal patients and to determine their equivalence and interchangeability. Methods Retrospective analysis of 100 eyes from 50 patients evaluated by ultrasound pachymetry (Pachette II), scanning-slit (Orbscan II), Scheimpflug (Pentacam HR) and spectral-domain ocular coherence tomography (OCT) (RTVue-100) obtained as average values (OCT-A) and point measurements (OCT-P). Measurements included central corneal thickness (CCT) for all technologies and thinnest corneal thickness for scanning-slit, Scheimpflug and OCT. Peripheral thickness measurements were obtained at the 3mm radius in the superior (S), nasal (N), inferior (I) and temporal (T) regions. Results CCT values were: 563.936.1 ultrasound, 570.9 +/- 36.1 scanning-slit, 552.8 +/- 33.8 Scheimpflug, 550.5 +/- 32.7 (OCT-A), 549.4 +/- 32.7 (OCT-P). Ultrasound and scanning-slit were significantly different from each other (p<0.0001), and both were significantly different from all other devices (p<0.0001), while Scheimpflug was similar to OCT-A and OCT-P (p=0.4). Differences between CCT and thinnest corneal thickness were significantly different from all technologies except scanning-slit and OCT-A. For peripheral values, almost all locations' measurements were significantly different from one another (p<0.0001). Superior-inferior values and ratios were also significantly different from one another for almost all devices with no consistent patterns detectible. Conclusions There are significant clinically relevant differences between regional and relational thickness measurements obtained with ultrasound, scanning-slit, Scheimpflug and OCT devices. Screening metrics devised for one system do not appear directly applicable to other measurement systems.
引用
收藏
页码:1176 / 1181
页数:6
相关论文
共 27 条
  • [1] Comparison of central corneal thickness measurements by rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography
    Amano, S
    Honda, N
    Amano, Y
    Yamagami, S
    Miyai, T
    Samejima, T
    Ogata, M
    Miyata, K
    [J]. OPHTHALMOLOGY, 2006, 113 (06) : 937 - 941
  • [2] Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus
    Ambrosio, Renato, Jr.
    Caiado, Ana Laura C.
    Guerra, Frederico P.
    Louzada, Ricardo
    Roy, Abhijit Sinha
    Luz, Allan
    Dupps, William J.
    Belin, Michael W.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) : 753 - 758
  • [3] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [4] Average 3-Dimensional Models for the Comparison of Orbscan II and Pentacam Pachymetry Maps in Normal Corneas
    Bourges, Jean-Louis
    Alfonsi, Nicolas
    Laliberte, Jean-Francois
    Chagnon, Miguel
    Renard, Gilles
    Legeais, Jean-Marc
    Brunette, Isabelle
    [J]. OPHTHALMOLOGY, 2009, 116 (11) : 2064 - 2071
  • [5] Comparison of three methods of measuring corneal thickness and anterior chamber depth
    Buehl, W
    Stojanac, D
    Sacu, S
    Drexler, W
    Findl, O
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (01) : 7 - 12
  • [6] Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry
    Chen, Shihao
    Huang, Jinhai
    Wen, Daizong
    Chen, Wuhe
    Huang, David
    Wang, Qinmei
    [J]. ACTA OPHTHALMOLOGICA, 2012, 90 (05) : 449 - 455
  • [7] Mathematical Approximation of Orbscan II Central Corneal Thickness to Contact Ultrasound
    Elbaz, Uri
    Zadok, David
    Frenkel, Shahar
    Pokroy, Russell
    Orucoglu , Faik
    Caspi, Ziv
    Landau, David
    Strassman, Eyal
    Perry, Joseph F.
    [J]. CORNEA, 2013, 32 (06) : 772 - 778
  • [8] Topographic Paracentral Corneal Thickness With Pentacam and Orbscan: Effect of Acoustic Factor
    Gonzalez-Perez, Javier
    Gonzalez-Meijome, Jose M.
    Rodriguez Ares, Maria T.
    Parafita, Manuel A.
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (06): : 348 - 353
  • [9] Central Corneal Thickness Measured With Three Optical Devices and Ultrasound Pachometry
    Gonzalez-Perez, Javier
    Manuel Gonzalez-Meijome, Jose
    Rodriguez Ares, Maria Teresa
    Angel Parafita, Manuel
    [J]. EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2011, 37 (02): : 66 - 70
  • [10] Corneal thickness, curvature, and elevation readings in normal corneas: Combined Placido-Scheimpflug system versus combined Placido-scanning-slit system
    Guilbert, Emmanuel
    Saad, Alain
    Grise-Dulac, Alice
    Gatinel, Damien
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (07) : 1198 - 1206