Hydrodynamic characteristics of the helical flow pump

被引:8
|
作者
Ishii, Kohei [1 ,2 ]
Hosoda, Kyohei [1 ]
Nishida, Masahiro [3 ]
Isoyama, Takashi [1 ]
Saito, Itsuro [1 ]
Ariyoshi, Koki [1 ]
Inoue, Yusuke [1 ]
Ono, Toshiya [1 ]
Nakagawa, Hidemoto [1 ]
Sato, Masami [1 ]
Hara, Sintaro [1 ]
Lee, Xinyang [1 ]
Wu, Sheng-Yuan [1 ]
Imachi, Kou [1 ]
Abe, Yusuke [1 ]
机构
[1] Univ Tokyo, Dept Biomed Engn, Grad Sch Med, Bunkyo Ku, Tokyo 1130033, Japan
[2] Kagawa Natl Coll Technol, Dept Electromech Syst Engn, Takamatsu, Kagawa, Japan
[3] Natl Inst Adv Ind Sci & Technol, Inst Human Sci & Biomed Engn, Tsukuba, Ibaraki, Japan
关键词
Helical flow pump; Rotary blood pump; Flow visualization; Computational fluid dynamics analysis; Total artificial heart; TOTAL ARTIFICIAL-HEART; REPLACEMENT;
D O I
10.1007/s10047-015-0828-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The helical flow pump (HFP) was invented to be an ideal pump for developing the TAH and the helical flow TAH (HFTAH) using two HFPs has been developed. However, since the HFP is quite a new pump, hydrodynamic characteristics inside the pump are not clarified. To analyze hydrodynamic characteristics of the HFP, flow visualization study using the particle image velocimetry and computational fluid dynamics analysis were performed. The experimental and computational models were developed to simulate the left HFP of the HFTAH and distributions of flow velocity vectors, shear stress and pressure inside the pump were examined. In distribution of flow velocity vectors, the vortexes in the vane were observed, which indicated that the HFP has a novel and quite unique working principle in which centrifugal force rotates the fluid in the helical volutes and the fluid is transferred from the inlet to the outlet helical volutes according to the helical structure. In distribution of shear stress, the highest shear stress that was considered to be occurred by the shunt flow across the impeller was found around the entrance of the inlet helical volute. However, it was not so high to cause hemolysis. This shunt flow is thought to be improved by redesigning the inlet and outlet helical volutes. In distribution of pressure, negative pressure was found near the entrance of the inlet helical volute. However, it was not high. Negative pressure is thought to be reduced with an improvement in the design of the impeller or the vane shape.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [41] Investigation of flow mechanism of a robotic fish swimming by using flow visualization synchronized with hydrodynamic force measurement
    Guang-Kun Tan
    Gong-Xin Shen
    Shuo-Qiao Huang
    Wen-Han Su
    Yu Ke
    Experiments in Fluids, 2007, 43 : 811 - 821
  • [42] Comparison Study of Hydrodynamic Characteristics in Different Swimming Modes of Carassius auratus
    Zhang, Ying
    Jing, Di
    Huang, Xiaoshuang
    Chen, Xinjun
    Liu, Bilin
    Kong, Xianghong
    FISHES, 2024, 9 (09)
  • [43] A novel intraaortic axial flow pump: dynamic aortic valve
    李国荣
    赵红
    马维国
    胡盛寿
    朱晓东
    任兵
    ProgressinNaturalScience, 2000, (06) : 53 - 58
  • [44] A novel intraaortic axial flow pump: dynamic aortic valve
    Li, GR
    Zhao, H
    Ma, WG
    Hu, SS
    Zhu, XD
    Ren, B
    PROGRESS IN NATURAL SCIENCE, 2000, 10 (06) : 451 - 456
  • [45] Washout hole flow measurement for the development of a centrifugal blood pump
    Nishida, M
    Yamane, T
    Asztalos, B
    ARTIFICIAL ORGANS, 1998, 22 (05) : 386 - 392
  • [46] Flow visualization study to improve hemocompatibility of a centrifugal blood pump
    Nishida, M
    Asztalos, B
    Yamane, T
    Masuzawa, T
    Tsukiya, T
    Endo, S
    Taenaka, Y
    Miyazoe, Y
    Ito, K
    Konishi, Y
    ARTIFICIAL ORGANS, 1999, 23 (08) : 697 - 703
  • [47] Flow visualization in a centrifugal blood pump with an eccentric inlet port
    Yamane, T
    Kodama, T
    Yamamoto, Y
    Shinohara, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2004, 28 (06) : 564 - 570
  • [48] Investigation of Blood Hemolysis Study in Rotary Blood Pump between Continuous Flow and Pulsatile Flow
    Rungsirikunnan, Chitsanupong
    Mondee, Kamonwan
    Gesprasert, Goragoch
    Naiyanetr, Phornphop
    2018 11TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2018), 2018,
  • [49] Analysis of the HeartWare HVAD pump characteristics under pulsatile operation
    Mapley, Martin C.
    Seah, E-Peng
    Semenzin, Clayton
    Wu, Eric
    Pauls, Jo P.
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2021, 68
  • [50] Evaluation of Left Ventricular Relaxation in Rotary Blood Pump Recipients Using the Pump Flow Waveform: A Simulation Study
    Moscato, Francesco
    Granegger, Marcus
    Naiyanetr, Phornphop
    Wieselthaler, Georg
    Schima, Heinrich
    ARTIFICIAL ORGANS, 2012, 36 (05) : 470 - 478