Hydrodynamic characteristics of the helical flow pump

被引:8
|
作者
Ishii, Kohei [1 ,2 ]
Hosoda, Kyohei [1 ]
Nishida, Masahiro [3 ]
Isoyama, Takashi [1 ]
Saito, Itsuro [1 ]
Ariyoshi, Koki [1 ]
Inoue, Yusuke [1 ]
Ono, Toshiya [1 ]
Nakagawa, Hidemoto [1 ]
Sato, Masami [1 ]
Hara, Sintaro [1 ]
Lee, Xinyang [1 ]
Wu, Sheng-Yuan [1 ]
Imachi, Kou [1 ]
Abe, Yusuke [1 ]
机构
[1] Univ Tokyo, Dept Biomed Engn, Grad Sch Med, Bunkyo Ku, Tokyo 1130033, Japan
[2] Kagawa Natl Coll Technol, Dept Electromech Syst Engn, Takamatsu, Kagawa, Japan
[3] Natl Inst Adv Ind Sci & Technol, Inst Human Sci & Biomed Engn, Tsukuba, Ibaraki, Japan
关键词
Helical flow pump; Rotary blood pump; Flow visualization; Computational fluid dynamics analysis; Total artificial heart; TOTAL ARTIFICIAL-HEART; REPLACEMENT;
D O I
10.1007/s10047-015-0828-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The helical flow pump (HFP) was invented to be an ideal pump for developing the TAH and the helical flow TAH (HFTAH) using two HFPs has been developed. However, since the HFP is quite a new pump, hydrodynamic characteristics inside the pump are not clarified. To analyze hydrodynamic characteristics of the HFP, flow visualization study using the particle image velocimetry and computational fluid dynamics analysis were performed. The experimental and computational models were developed to simulate the left HFP of the HFTAH and distributions of flow velocity vectors, shear stress and pressure inside the pump were examined. In distribution of flow velocity vectors, the vortexes in the vane were observed, which indicated that the HFP has a novel and quite unique working principle in which centrifugal force rotates the fluid in the helical volutes and the fluid is transferred from the inlet to the outlet helical volutes according to the helical structure. In distribution of shear stress, the highest shear stress that was considered to be occurred by the shunt flow across the impeller was found around the entrance of the inlet helical volute. However, it was not so high to cause hemolysis. This shunt flow is thought to be improved by redesigning the inlet and outlet helical volutes. In distribution of pressure, negative pressure was found near the entrance of the inlet helical volute. However, it was not high. Negative pressure is thought to be reduced with an improvement in the design of the impeller or the vane shape.
引用
收藏
页码:206 / 212
页数:7
相关论文
共 50 条
  • [31] EFFECT OF TUBING LENGTH PUMP ON FLOW DERIVED INDEX DURING ROTARY BLOOD PUMP SUPPORT
    Khienwad, Thananya
    Deepankaew, Ronnachit
    Wannawat, Praemai
    Naiyanetr, Phornphop
    2017 13TH IASTED INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING (BIOMED), 2017, : 270 - 276
  • [32] Histopathology Image Analysis in Two Long-Term Animal Experiments with Helical Flow Total Artificial Heart
    Wotke, Jiri
    Homolka, Pavel
    Vasku, Jaromir
    Dobsak, Petr
    Palanova, Petra
    Mrkvicova, Veronika
    Konecny, Petr
    Soska, Vladimir
    Pohanka, Michal
    Novakova, Marie
    Yurimoto, Terumi
    Saito, Itsuro
    Inoue, Yusuke
    Isoyama, Takashi
    Abe, Yusuke
    ARTIFICIAL ORGANS, 2016, 40 (12) : 1137 - 1145
  • [33] A FLOW VISUALIZATION STUDY OF THE NCVC CENTRIFUGAL BLOOD PUMP
    ARAKI, K
    TAENAKA, Y
    MASUZAWA, T
    TATSUMI, E
    WAKISAKA, Y
    WATARI, M
    NAKATANI, T
    AKAGI, H
    BABA, Y
    ANAI, H
    PARK, YH
    EYA, K
    TODA, K
    TAKANO, H
    ARTIFICIAL ORGANS, 1994, 18 (09) : 669 - 672
  • [34] Visualization of flow structure in a centrifugal blood pump impeller
    Tsukiya T.
    Taenaka Y.
    Tatsumi E.
    Takano H.
    Journal of Artificial Organs, 2002, 5 (1) : 13 - 17
  • [35] Flow visualization studies to improve the spiral pump design
    Andrade, A
    Biscegli, J
    Sousa, JE
    Ohashi, Y
    Nose, Y
    ARTIFICIAL ORGANS, 1997, 21 (07) : 680 - 685
  • [36] In vitro analysis of the flow fields of a rotary blood pump
    Morsi, Y
    Yang, W
    Chan, S
    COMPUTATIONAL MECHANICS, VOLS 1 AND 2, PROCEEDINGS: NEW FRONTIERS FOR THE NEW MILLENNIUM, 2001, : 875 - 880
  • [37] Bearing dynamic characteristics of the ventrassist rotary blood pump
    Chung, M
    Zhang, N
    Tansley, GD
    Woodard, JC
    PROCEEDINGS OF THE 5TH INTERNATIONAL CONFERENCE ON VIBRATION ENGINEERING, 2002, : 155 - 161
  • [38] Flow visualization study to investigate the secondary flow behind the impeller in the gyro centrifugal pump
    Ichikawa, S
    Nonaka, K
    Linneweber, J
    Kawahito, S
    Motomura, T
    Ishitoya, H
    Mikami, M
    Nishimura, I
    Glueck, J
    Shinohara, T
    Nosé, Y
    ARTIFICIAL ORGANS, 2002, 26 (12) : 1050 - 1052
  • [39] HYDRODYNAMIC ANALYSIS OF A TURBULENT FLOW IN AN ANNULAR SPACE WITH INSERTED WIRE SPIRAL
    Imbert-Gonzalez, J.
    Garcia-Valladares, O.
    Guillen-Gordin, R.
    REVISTA MEXICANA DE INGENIERIA QUIMICA, 2016, 15 (01): : 149 - 159
  • [40] Unsteady hydrodynamic forces acting on a robotic hand and its flow field
    Takagi, Hideki
    Nakashima, Motomu
    Ozaki, Takashi
    Matsuuchi, Kazuo
    JOURNAL OF BIOMECHANICS, 2013, 46 (11) : 1825 - 1832