Biomechanical comparison of locked plating and spiral blade retrograde nailing of supracondylar femur fractures

被引:11
作者
Assari, Soroush [1 ]
Kaufmann, Alan [1 ]
Darvish, Kurosh [1 ]
Park, Jung [2 ]
Haw, Jonathan [2 ]
Safadi, Fayez [3 ]
Rehman, Saqib [2 ]
机构
[1] Temple Univ, Dept Mech Engn, Philadelphia, PA 19122 USA
[2] Temple Univ Hosp & Med Sch, Dept Orthoped Surg, Philadelphia, PA 19140 USA
[3] Temple Univ, Sch Med, Dept Anat & Cell Biol, Philadelphia, PA 19140 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2013年 / 44卷 / 10期
关键词
Supracondylar femur fracture; Locking Condylar Plate; Retrograde/Antegrade Femoral Nail; Axial stiffness; Postoperative weight-bearing; DISTAL FEMORAL FRACTURES; INTERNAL-FIXATION; OSTEOPOROTIC BONE; EPIDEMIOLOGY;
D O I
10.1016/j.injury.2013.04.016
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: Biomechanical comparison between locked plating and retrograde nailing of supracondylar femur fractures with simulated postoperative weight-bearing. Methods: The Locking Condylar Plate (LCP) and Retrograde/Antegrade EX Femoral Nail (RAFN) were tested using 10 paired elderly cadaveric femurs, divided into Normal and Low Bone Mineral Density (BMD) groups, with a simulated AO/OTA type 33-A3 supracondylar femur fracture. Each specimen was subjected to 200,000 loading cycles in an attempt to simulate six weeks of postoperative recovery with full weight-bearing for an average individual. The construct's subsidence due to cyclic loading, and axial stiffness before and after the cyclic loading were measured and their correlation with BMD was studied. The two implants were compared in a paired study within each BMD group. Results: LCP constructs showed higher axial stiffness compared to RAFN for both Normal and Low BMD groups (80% and 57%, respectively). After cyclic loading, axial stiffness of both constructs decreased by 20% and RAFN constructs resulted in twice as much subsidence (1.9 +/- 0.6 mm). Two RAFN constructs with Low BMD failed after a few cycles whereas the matched pairs fixed with LCP failed after 70,000 cycles. Conclusions: The RAFN constructs experienced greater subsidence and reduced axial stiffness compared to the LCP constructs. In Low BMD specimens, the RAFN constructs had a higher risk of failure. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1340 / 1345
页数:6
相关论文
共 16 条
  • [1] Anisotropy of the elastic modulus of trabecular bone specimens from different anatomical locations
    Augat, P
    Link, T
    Lang, TF
    Lin, JC
    Majumdar, S
    Genant, HK
    [J]. MEDICAL ENGINEERING & PHYSICS, 1998, 20 (02) : 124 - 131
  • [2] Epidemiology of adult fractures: A review
    Court-Brown, Charles M.
    Caesar, Ben
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (08): : 691 - 697
  • [3] Distal Femoral Fixation: A Biomechanical Comparison of Trigen Retrograde Intramedullary (IM) Nail, Dynamic Condylar Screw (DCS), and Locking Compression Plate (LCP) Condylar Plate
    Heiney, Jake P.
    Barnett, Michael D.
    Vrabec, Gregory A.
    Schoenfeld, Andrew J.
    Baji, Avinash
    Njus, Glen O.
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2009, 66 (02): : 443 - 449
  • [4] Biomechanical analysis of distal femur fracture fixation: Fixed-angle screw-plate construct versus condylar blade plate
    Higgins, Thomas F.
    Pittman, Gavin
    Hines, Jerod
    Bachus, Kent N.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (01) : 43 - 46
  • [5] Improved intramedullary nail interlocking in osteoporotic bone
    Ito, K
    Hungerbühler, R
    Wahl, D
    Grass, F
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) : 192 - 196
  • [6] Internal fixation of supracondylar femoral fractures: Comparative biomechanical performance of the 95-degree blade plate and two retrograde nails
    Ito, K
    Grass, R
    Zwipp, H
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) : 259 - 266
  • [7] Biomechanical evaluation of the less invasive stabilization system for the internal fixation of distal femur fractures
    Marti, A
    Fankhauser, C
    Frenk, A
    Cordey, J
    Gasser, B
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (07) : 482 - 487
  • [8] The epidemiology of fractures of the distal femur
    Martinet, O
    Cordey, J
    Harder, Y
    Maier, A
    Bühler, M
    Barraud, GE
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 : 62 - 63
  • [9] Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures
    Otto, Randall J.
    Moed, Berton R.
    Bledsoe, J. Gary
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 645 - 652
  • [10] Evolution of the internal fixation of long bone fractures - The scientific basis of biological internal fixation: Choosing a new balance between stability and biology
    Perren, SM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (08): : 1093 - 1110