Design of an Accurate Near Infrared Optical Tracking System in Surgical Navigation

被引:35
作者
Yang, Rongqian [1 ]
Wang, Zhigang [2 ]
Liu, Sujuan [3 ]
Wu, Xiaoming [1 ]
机构
[1] S China Univ Technol, Dept Biomed Engn, Guangzhou 510006, Guangdong, Peoples R China
[2] ZTE Corp, Shenzhen 518057, Peoples R China
[3] Anke High Technol Co, Shenzhen 518067, Peoples R China
基金
中国国家自然科学基金;
关键词
Near infrared camera calibration; optical tracking; stereo matching; surgical navigation; ONE-DIMENSIONAL OBJECTS; CAMERA CALIBRATION; RECONSTRUCTION;
D O I
10.1109/JLT.2012.2227943
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Near infrared optical tracking system (NIOTS) is widely used in biomedical application, especially in surgical navigation. It largely determines the accuracy of tracking surgical tools. So we design an NIOTS and propose the corresponding algorithms to make it work well. Two near infrared cameras (NICs) are constructed in this NIOTS and a near infrared calibration board is designed to calibrate them. The NIOTS is then calibrated using the calibration results of NICs. After the image points of markers on surgical tools are obtained, a two-step stereo matching algorithm is proposed to match the subpixel points in the left and right images. Then the three dimensional coordinates of markers are computed and the surgical tools are tracked in real time. The experimental results show the accuracy of system calibration, stereo matching, and tracking. The average tracking errors of three markers in 150 positions are 0.0090 mm, 0.0071 mm, and 0.0060 mm, which demonstrate the designed NIOTS can accurately track surgical tools.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 25 条
[11]  
LOT-Oriel GmbH & Co, 2012, KG NIR SWIR CAM 2012
[12]  
Lovell-Smith C. D., 2009, THESIS U CANTERBURY
[13]  
Northern Digital Inc, 2012, POL FAM OPT TRACK SY
[14]   Camera calibration using one-dimensional information and its applications in both controlled and uncontrolled environments [J].
Peng, En ;
Li, Ling .
PATTERN RECOGNITION, 2010, 43 (03) :1188-1198
[15]   Analysis of surgeon's line of sight using an optical tracking system with a multifaceted marker device [J].
Tsunezuka, Hiroaki ;
Kato, Daishiro ;
Terauchi, Kunihiko ;
Shimomura, Masanori ;
Ichise, Kaori ;
Ito, Kazuhiro ;
Nishikawa, Atsushi ;
Shimada, Junichi .
INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2011, 6 (06) :803-809
[16]  
Wang L, 2011, LECT NOTES COMPUT SC, V6761, P660, DOI 10.1007/978-3-642-21602-2_72
[17]   Camera calibration using identical objects [J].
Wang, Ruiyan ;
Jiang, Guang ;
Quan, Long ;
Wu, Chengke .
MACHINE VISION AND APPLICATIONS, 2012, 23 (03) :579-587
[18]   The Camera Itself as a Calibration Pattern: A Novel Self-Calibration Method for Non-Central Catadioptric Cameras [J].
Xiang, Zhiyu ;
Sun, Bo ;
Dai, Xing .
SENSORS, 2012, 12 (06) :7299-7317
[19]   Flexible and accurate implementation of a binocular structured light system [J].
Yang, Rongqian ;
Cheng, Sheng ;
Chen, Yazhu .
OPTICS AND LASERS IN ENGINEERING, 2008, 46 (05) :373-379
[20]   Geometric Calibration of IR Camera Using Trinocular Vision [J].
Yang, Rongqian ;
Yang, Wei ;
Chen, Yazhu ;
Wu, Xiaoming .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2011, 29 (24) :3797-3803