Metal Artifact Reduction Based on Beam Hardening Correction and Statistical Iterative Reconstruction for X-ray Computed Tomography

被引:7
|
作者
Zhang, Yanbo [1 ]
Mou, Xuanqin [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
来源
MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING | 2013年 / 8668卷
关键词
Computed tomography; metal artifacts; beam hardening; statistical reconstruction; IMAGE-RECONSTRUCTION; TRANSMISSION TOMOGRAPHY; CT; SIMULATION;
D O I
10.1117/12.2008176
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Metal artifact is a main cause to degrade CT image quality, but there is still no standard solution to this issue. The cause of introduction of metal artifacts is due to several physical effects, in which beam hardening and noise are two major factors. Accordingly, in this paper these two factors are alleviated by using beam hardening correction based on polynomial fitting and statistical iterative reconstruction based on Poisson log-likelihood approach. Unlike other metal artifact reduction (MAR) methods by using iterative image reconstruction from polychromatic projection dataset, the proposed method in this work does not require a priori knowledge about the X-ray spectrum and attenuations of the materials to be reconstructed. A conventional linear interpolation MAR algorithm and two MAR methods based on beam hardening correction are performed for comparison. Simulation results illustrate that the proposed method can suppress metal artifacts greatly and restore low contrast tissues well.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Novel methods for metal artifact reduction in x-ray tomography
    Cho, Seungryong
    Lee, Jung Ryun
    2018 INTERNATIONAL WORKSHOP ON ADVANCED IMAGE TECHNOLOGY (IWAIT), 2018,
  • [22] Fast iterative beam hardening correction based on frequency splitting in computed tomography
    Yang, Qiao
    Elter, Matthias
    Schasiepen, Ingo
    Maass, Nicole
    Hornegger, Joachim
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [23] A Review of Common Beam Hardening Correction Methods for Industrial X-ray Computed Tomography
    Ahmed, O. M. H.
    Song, Yushou
    SAINS MALAYSIANA, 2018, 47 (08): : 1883 - 1890
  • [24] High-kVp Assisted Metal Artifact Reduction for X-Ray Computed Tomography
    Xi, Yan
    Jin, Yannan
    De Man, Bruno
    Wang, Ge
    IEEE ACCESS, 2016, 4 : 4769 - 4776
  • [25] Sparsity Constrained Sinogram Inpainting for Metal Artifact Reduction in X-ray Computed Tomography
    Mehranian, A.
    Ay, M. R.
    Rahmim, A.
    Zaidi, H.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3694 - 3699
  • [26] Analytical expressions for the reconstructed image of a homogeneous cylindrical sample exhibiting a beam hardening artifact in X-ray computed tomography
    Nakano, Tsukasa
    Nakashima, Yoshito
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (05) : 691 - 705
  • [27] Metal Artifact Reduction for X-Ray Computed Tomography Using U-Net in Image Domain
    Zhu, Linlin
    Han, Yu
    Li, Lei
    Xi, Xiaoqi
    Zhu, Mingwan
    Yan, Bin
    IEEE ACCESS, 2019, 7 : 98743 - 98754
  • [28] Using Experiment and Simulation to Understand the Effects of Source Filtering on Artifact Reduction for Industrial X-ray Computed Tomography
    Roth, Don
    MATERIALS EVALUATION, 2020, 78 (02) : 203 - 212
  • [29] A HYBRID ITERATIVE ALGORITHM FOR RECONSTRUCTION OF X-RAY COMPUTED TOMOGRAPHY
    Zefreh, EbrahimZarei
    FarzadDidehvar
    NasrinNasrabadi
    MALAYSIAN JOURNAL OF COMPUTER SCIENCE, 2015, 28 (01) : 46 - 58
  • [30] TV-Based Correction for Beam Hardening in Computed Tomography
    Zou, Xiaobing
    Li, Zongjian
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2016, 6 (07) : 1701 - 1707