Hemp-FRP for Seismic Retrofitting of Existing Masonry Buildings

被引:2
|
作者
Formisano, Antonio [1 ]
Vaiano, Generoso [1 ]
Petrucci, Nicola, Jr. [1 ]
机构
[1] Univ Naples Federico II, Dept Struct Engn & Architecture, Piazzale Tecchio 80, I-80125 Naples, Italy
来源
PROTECTION OF HISTORICAL CONSTRUCTIONS, PROHITECH 2021 | 2022年 / 209卷
关键词
Hemp; Natural fibres; Green composites; Seismic retrofitting; FE analysis; FAILURE ANALYSIS; CHURCHES; VULNERABILITY; DAMAGE; MEDIEVAL; BEHAVIOR; DESIGN; TOWERS;
D O I
10.1007/978-3-030-90788-4_33
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Nowadays, renewable technologies and reduced environmental impacts are important concepts of the modern construction systems, especially in relation to the production of building materials. In this framework, the seismic performance of H-FRPs (Hemp - Fibre Reinforced Polymers) for retrofitting masonry structures are studied in the current paper, where both analytical and experimental researches on laminated composite green materials are reported and discussed. With respect to analytical studies, proper equations ruling the percentages of fibres and matrixes to be used in green composites are examined. Moreover, full scale experimental tests in order to evaluate the hemp fibres mechanical behaviour and the seismic behaviour of masonry panels are taken into account. The numerical calibration of the above experimental tests are conducted with the ABAQUS non linear numerical software in order to know the behaviour of hemp fibres and masonry walls under the combined effect of vertical and horizontal actions. This activity is used to apply hemp fibres under form of a grid of strips (with variable pitch) as seismic retrofitting system applied on one or both sides of an existing masonry panel. The behaviour of hemp strips in terms of resistance and ductility is compared to that of C-FRP (Carbon - Fibre Reinforced Polymer) ones aiming at both evaluating the effectiveness of using green fibres and finding the best retrofitting system of the analyzed masonry panel. The analysis results have shown the convenience of using hemp fibres, which allow to perform low cost and minimally invasive seismic interventions without the building disruption of use, offering at the same time strength and ductility comparable to those of the most famous C-FRP materials.
引用
收藏
页码:402 / 417
页数:16
相关论文
共 50 条
  • [1] Seismic collapse simulation of existing masonry buildings with different retrofitting techniques
    Ge Dongdong
    Du Chunbo
    Miao Qisong
    Chen Xi
    EARTHQUAKE ENGINEERING AND ENGINEERING VIBRATION, 2021, 20 (01) : 127 - 139
  • [2] Seismic Retrofitting of Traditional Masonry with Pultruded FRP Profiles
    Sciarretta, Francesca
    APPLIED SCIENCES-BASEL, 2020, 10 (07):
  • [3] Hemp FRCM as bio-based technique for seismic consolidation of existing masonry buildings
    Davino, Antonio
    Meglio, Emilia
    Formisano, Antonio
    INTERNATIONAL JOURNAL OF MASONRY RESEARCH AND INNOVATION, 2025, 10 (02)
  • [4] Seismic Assessment and Retrofitting of a Heritage Brick Masonry Building Using FRP
    Tomar, Anshu
    Paul, Dilip Kumar
    Agarwal, Pankaj
    JOURNAL OF EARTHQUAKE AND TSUNAMI, 2019, 13 (01)
  • [5] Innovative Method for Seismic and Energy Retrofitting of Masonry Buildings
    Facconi, Luca
    Lucchini, Sara S.
    Minelli, Fausto
    Grassi, Benedetta
    Pilotelli, Mariagrazia
    Plizzari, Giovanni A.
    SUSTAINABILITY, 2021, 13 (11)
  • [6] Seismic Retrofitting of Existing Industrial Steel Buildings: A Case-Study
    Tartaglia, Roberto
    Milone, Aldo
    Prota, Alessandro
    Landolfo, Raffaele
    MATERIALS, 2022, 15 (09)
  • [7] Seismic evaluation and retrofitting of the structures of the Sadaghiani masonry historical complex
    Kheirollahi, Mohammad
    Mirzaei, Moein
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2023, 19
  • [8] Sensitivity analysis of the seismic performance of existing masonry buildings
    Mendes, Nuno
    Lourenco, Paulo B.
    ENGINEERING STRUCTURES, 2014, 80 : 137 - 146
  • [9] Design of Additional Dissipative Structures for Seismic Retrofitting of Existing Buildings
    Bergami, Alessandro Vittorio
    APPLIED SCIENCES-BASEL, 2024, 14 (06):
  • [10] Seismic assessment of existing RC buildings before and after shear-wall retrofitting
    Onat, Onur
    Yon, Burak
    Calayir, Yusuf
    GRADEVINAR, 2018, 70 (08): : 703 - 712