Solid phase extraction of proteins from buffer solutions employing capillary-channeled polymer (C-CP) fibers as the stationary phase

被引:20
作者
Burdette, Carolyn Q. [1 ]
Marcus, R. Kenneth [1 ]
机构
[1] Clemson Univ, Dept Chem, Clemson, SC 29634 USA
基金
美国国家科学基金会;
关键词
ION-EXCHANGE-RESINS; PERFORMANCE LIQUID-CHROMATOGRAPHY; IONIZATION MASS-SPECTROMETRY; SAMPLE PREPARATION; SURFACE MODIFICATION; HIGH-THROUGHPUT; PART II; SEPARATIONS; COLUMNS; SORBENT;
D O I
10.1039/c2an36126d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Polypropylene (PP) capillary-channeled polymer (C-CP) fibers are applied for solid phase extraction (SPE) of proteins from aqueous buffer solutions using a micropipette tip-based format. A process was developed in which centrifugation is used as the moving force for solution passage in the loading/washing steps instead of the previously employed manual aspiration. The complete procedure requires similar to 15 minutes, with the number of samples run in parallel limited only by the capacity of the centrifuge. The method performance was evaluated based on adsorption and elution characteristics of several proteins (cytochrome c, lysozyme, myoglobin, and glucose oxidase) from 150 mM phosphate buffered saline (PBS) solutions. Protein concentration ranges of similar to 2 to 100 mu g mL(-1) were employed and the recovery characteristics determined through UV-Vis absorbance spectrophotometry for protein quantification. The protein loading capacities across the range of proteins was similar to 1.5 mu g for the 5 mg fiber tips. Average recoveries from PBS were determined for each protein sample; cytochrome c similar to 86%, lysozyme similar to 80%, myoglobin similar to 86%, and glucose oxidase similar to 89%. Recoveries from more complex matrices, synthetic urine and synthetic saliva, were determined to be similar to 90%. A 10x dilution study for a fixed 1 mu g protein application yielded 94 +/- 3.2% recoveries. The C-CP tips provided significantly higher recoveries for myoglobin in a 150 mM PBS matrix in comparison to a commercially available protein SPE product, with the added advantages of low cost, rapid processing, and reusability.
引用
收藏
页码:1098 / 1106
页数:9
相关论文
共 68 条
[1]   Dye attached poly(hydroxyethyl methacrylate) cryogel for albumin depletion from human serum [J].
Andac, Muge ;
Galaev, Igor ;
Denizli, Adil .
JOURNAL OF SEPARATION SCIENCE, 2012, 35 (09) :1173-1182
[2]  
[Anonymous], 2000, SOLID PHASE EXTRACTI
[3]  
[Anonymous], SPE CARTR TUB CONF G
[4]  
[Anonymous], 1998, SUP, P1
[6]   Application of the Phenomenex EZ:faast™ amino acid analysis kit for rapid gas-chromatographic determination of concentrations of plasma tryptophan and its brain uptake competitors [J].
Badawy, A. A. -B. ;
Morgan, C. J. ;
Turner, J. A. .
AMINO ACIDS, 2008, 34 (04) :587-596
[7]   Desalting of in-gel-digested protein sample with mini-C18 columns for matrix-assisted laser desorption ionization time of flight peptide mass fingerprinting [J].
Bagshaw, RD ;
Callahan, JW ;
Mahuran, DJ .
ANALYTICAL BIOCHEMISTRY, 2000, 284 (02) :432-435
[8]   Two new techniques for sample preparation in bioanalysis: Microextraction in packed sorbent (MEPS) and use of a bonded monolith as sorbent for sample preparation in polypropylene tips for 96-well plates [J].
Blomberg, Lars G. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (03) :797-807
[9]  
Brown P., 2006, Polymer Prep, V47, P551
[10]   Comparison of protein adsorption isotherms and uptake rates in preparative cation-exchange materials [J].
Chang, C ;
Lenhoff, AM .
JOURNAL OF CHROMATOGRAPHY A, 1998, 827 (02) :281-293