The effect of fibres on steel bar corrosion and flexural behaviour of corroded RC beams

被引:44
作者
Berrocal, Carlos G. [1 ,2 ]
Lofgren, Ingemar [1 ,2 ]
Lundgren, Karin [1 ]
机构
[1] Chalmers Univ Technol, Div Struct Engn, SE-41296 Gothenburg, Sweden
[2] Thomas Concrete Grp AB, Sodra Vagen 28, S-41254 Gothenburg, Sweden
关键词
Corrosion; Cracking; Fiber reinforced concrete; Rotation capacity; Crack width; CHLORIDE-INDUCED CORROSION; REINFORCED-CONCRETE BEAMS; CRACK WIDTH; STRUCTURAL PERFORMANCE; MECHANICAL-PROPERTIES; SIGMA-EPSILON; FATIGUE; DAMAGE; COVER;
D O I
10.1016/j.engstruct.2018.02.068
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper reports the results of an experimental programme aimed at investigating the influence of fibre reinforcement on the corrosion process of conventional steel rebar embedded in cracked concrete and on the flexural behaviour of reinforced concrete beams. Un- and pre-cracked reinforced concrete beams were subjected to natural corrosion through cyclic exposure to a 10% chloride solution for a period of three years. Subsequently, flexural tests were carried out under three-point bending configuration. Gravimetric measurements showed higher corrosion levels for bars in plain concrete compared to fibre reinforced concrete, and visual inspection of the bars revealed that fibres promoted a more distributed corrosion pattern. From detailed examination of the bars through 3D laser scanning technique, the main parameter controlling the local corrosion level of individual pits appears to be the local interfacial conditions; grater loads during pre-cracking and repeated load cycles yielded greater cross-sectional losses. Moreover, there was a tendency for more localized corrosion in beams with open cracks, indicating a possible impact of crack width on the extension of corrosion. The results from the flexural tests showed a consistent increase of load capacity for fibre reinforced beams compared to their plain concrete counterparts but only a marginal influence of the fibres on the rotation capacity. Furthermore, the rotation capacity of the beams was found to decrease several times faster than the load capacity with increasing loss of rebar cross-sectional area.
引用
收藏
页码:409 / 425
页数:17
相关论文
共 78 条
[1]  
Abrishami HH, 1997, ACI STRUCT J, V94, P769
[2]  
Ahmed SFU, 2007, ACI MATER J, V104, P153
[3]   Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method [J].
Andrade, C ;
Alonso, C ;
Gulikers, J ;
Polder, R ;
Cigna, R ;
Vennesland, O ;
Salta, M ;
Raharinaivo, A ;
Elsener, B .
MATERIALS AND STRUCTURES, 2004, 37 (273) :623-643
[4]   Probabilistic considerations on the effect of specimen size on the critical chloride content in reinforced concrete [J].
Angst, Ueli ;
Ronnquist, Anders ;
Elsener, Bernhard ;
Larsen, Claus K. ;
Vennesland, Oystein .
CORROSION SCIENCE, 2011, 53 (01) :177-187
[5]  
[Anonymous], 1982, CEMENT CONCRETE RES
[6]  
[Anonymous], 137912007 EN
[7]  
[Anonymous], 2019, 123903 BS EN
[8]  
[Anonymous], 2005, 511 NT
[9]  
[Anonymous], 2010, FIB MOD COD CONCR ST
[10]  
[Anonymous], 146512007 EN