DETERMINATION OF LUTEOLIN AND APIGENIN IN HERBS BY CAPILLARY ELECTROPHORESIS WITH DIODE ARRAY DETECTION

被引:21
作者
Maher, Hadir M. [1 ,2 ]
Al-Zoman, Nourah Z. [1 ]
Al-Shehri, Mona M. [1 ]
Al-Showiman, Hessa [1 ]
Al-Taweel, Areej M. [3 ]
Fawzy, Ghada A. [3 ,4 ]
Perveen, Shagufta [3 ]
机构
[1] King Saud Univ, Coll Pharm, Dept Pharmaceut Chem, Riyadh 11495, Saudi Arabia
[2] Univ Alexandria, Dept Pharmaceut Analyt Chem, Fac Pharm, Alexandria, Egypt
[3] King Saud Univ, Coll Pharm, Dept Pharmacognosy, Riyadh 11495, Saudi Arabia
[4] Cairo Univ, Fac Pharm, Dept Pharmacognosy, Cairo, Egypt
关键词
apigenin; capillary electrophoresis; luteolin; parsley; thyme; PHENOLIC-COMPOUNDS; LIQUID-CHROMATOGRAPHY; POLYPHENOLIC COMPOUNDS; THYMUS-VULGARIS; FLAVONOIDS; EXTRACTS; ANTIOXIDANT; COMBINATION; SEPARATION; HYDROCHLOROTHIAZIDE;
D O I
10.1080/10739149.2015.1038560
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Capillary electrophoresis with a diode array detector was employed for the determination of luteolin and apigenin in plant extracts. The experimental factors affecting the elution of the analytes were carefully optimized. The final analysis was achieved utilizing a fused silica capillary (58cm effective length, 75m ID) and a background electrolyte solution consisting of borax buffer (20mM, pH 10.0) and methanol (90: 10, v/v) with a 23kV driving voltage and detection at 210nm. The method was fully validated as per the guidelines of the International Conference on Harmonization for Analytical Procedures. The relationship between peak area and concentration was linear between 3 and 800g/mL for both compounds with detection limits of 1.05 for luteolin and 0.53g/mL for apigenin. The method was employed for the determination of the analytes in extracts of thyme and parsley. Both compounds were resolved from interfering peaks that were present in the extracts. Recovery studies were performed by fortifying the extracts with standards and demonstrated good accuracy with recovery values between 97.29 and 104.88% for luteolin and 96.89 and 105.18% for apigenin. Thyme and parsley were shown to contain high concentrations of luteolin and apigenin.
引用
收藏
页码:611 / 625
页数:15
相关论文
共 50 条
  • [31] Determination of Nicotine in Tobacco by Capillary Electrophoresis with Electrochemical Detection
    Sun Jin-ying
    Xu Xiao-yu
    Yu Huan
    You Tian-yan
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2012, 28 (03) : 415 - 418
  • [32] Determination of terbutaline sulfate by capillary electrophoresis with chemiluminescence detection
    Li, Shuting
    Wang, Janshi
    Zhao, Shulin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 155 - 158
  • [33] Determination of imipramine and trimipramine by capillary electrophoresis with electrochemiluminescence detection
    Yu, Caixia
    Du, Hongwei
    You, Tianyan
    TALANTA, 2011, 83 (05) : 1376 - 1380
  • [34] Optimization for quantitative determination of four flavonoids in Epimedium by capillary zone electrophoresis coupled with diode array detection using central composite design
    Liu, JJ
    Li, SP
    Wang, YT
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (02) : 344 - 349
  • [35] Quick and Sensitive Determination of Fluoroquinolones by Capillary Electrophoresis-Potential Gradient Detection
    Fan, Yongxia
    Tian, Zhiren
    Qin, Weidong
    ANALYTICAL LETTERS, 2009, 42 (08) : 1057 - 1069
  • [36] A simple method for the analysis of extracellular vesicles enriched for exosomes from human serum by capillary electrophoresis with ultraviolet diode array detection
    El Ouahabi, Oumaima
    Salim, Hiba
    Pero-Gascon, Roger
    Benavente, Fernando
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1635
  • [37] Development and Validation of Improved Method for Fingerprint Analysis of Rhizoma Chuanxiong by Capillary Zone Electrophoresis with Ultraviolet-Diode Array Detection
    Wei, Feng Huan
    Shen, Qun
    Chen, Fei Long
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2014, 13 (05) : 773 - 778
  • [38] Plasma creatinine and creatine quantification by capillary electrophoresis diode array detector
    Zinellu, A
    Caria, MA
    Tavera, C
    Sotgia, S
    Chessa, R
    Delana, L
    Carru, C
    ANALYTICAL BIOCHEMISTRY, 2005, 342 (02) : 186 - 193
  • [39] Simultaneous determination of luteolin and apigenin in dog plasma by RP-HPLC
    Li, LP
    Jiang, HD
    Wu, HH
    Zeng, S
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (03) : 615 - 620
  • [40] Capillary electrophoresis tandem mass spectrometry with array detection
    Deterding, LJ
    Tomer, KB
    Wellemans, JMY
    Cerny, RL
    Gross, ML
    EUROPEAN MASS SPECTROMETRY, 1999, 5 (01): : 33 - 40