Differential energy based relaying for thyristor controlled series compensated line

被引:15
作者
Samantaray, S. R. [1 ]
Tripathy, L. N. [2 ]
Dash, P. K. [3 ]
机构
[1] Indian Inst Technol Bhubaneswar, Odisha, India
[2] IGIT, Sarang, Odisha, India
[3] SOA Univ, Bhubaneswar, Odisha, India
关键词
Differential energy; Flexible AC Transmission Systems (FACTs); Frequency contours; Fault patterns; S-transform; Thyristor Controlled Series Compensator (TCSC); TRANSMISSION-LINES; PROTECTION SCHEME; SYSTEM; TRANSFORM;
D O I
10.1016/j.ijepes.2012.06.023
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper presents a differential energy based protection scheme for transmission line including Thyristor Controlled Series Compensator (TCSC) using time-frequency transform such as S-transform. Initially the current at sending and receiving ends are retrieved and processed through the time-frequency transform such as S-transform to generate the time-frequency patterns (frequency contours). Spectral energy content of the frequency contours of both current signals are calculated and differential energy is computed to register the fault patterns in the transmission line. The tripping signal can be issued based on a set threshold, within two cycles from the fault inception, meeting the speed criteria of the digital relay. The results indicate that the differential energy based protection scheme can reliably detect the fault patterns in TCSC line including wide variations in operating conditions of the faulted power network. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:621 / 629
页数:9
相关论文
共 20 条
[11]   Fault classification technique for series compensated transmission line using support vector machine [J].
Parikh, Urmil B. ;
Das, Biswarup ;
Maheshwari, Rudraprakash .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (06) :629-636
[12]  
Parikh Urmil B, 2008, IEEE T POWER DEL
[13]   Synchronized phasor measurements in power systems [J].
Phadke, A.G. .
IEEE Computer Applications in Power, 1993, 6 (02) :10-15
[14]   The S-transform with windows of arbitrary and varying shape [J].
Pinnegar, CR ;
Mansinha, L .
GEOPHYSICS, 2003, 68 (01) :381-385
[15]   Accurate fault location algorithm for transmission line in the presence of series connected FACTS devices [J].
Sadeh, Javad ;
Adinehzadeh, Aniseh .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2010, 32 (04) :323-328
[16]   Wavelet packet-based digital relaying for advanced series compensated line [J].
Samantaray, S. R. ;
Dash, P. K. .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2007, 1 (05) :784-792
[17]   Artificial neural-network-based protection scheme for controllable series-compensated EHV transmission lines [J].
Song, YH ;
Johns, AT ;
Xuan, QY .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1996, 143 (06) :535-540
[18]   Protection scheme for EHV transmission systems with thyristor controlled series compensation using radial basis function neural networks [J].
Song, YH ;
Xuan, QY ;
Johns, AT .
ELECTRIC MACHINES AND POWER SYSTEMS, 1997, 25 (05) :553-565
[19]   A de-noising scheme for enhancing wavelet-based power quality monitoring system [J].
Yang, HT ;
Liao, CC .
IEEE TRANSACTIONS ON POWER DELIVERY, 2001, 16 (03) :353-360
[20]   Performance evaluation of a distance relay as applied to a transmission system with UPFC [J].
Zhou, Xiaoyao ;
Wang, Haifeng ;
Aggarwal, R. K. ;
Beaumont, Phil .
IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (03) :1137-1147