Revitalizing a Vital Sign: Improving Detection of Tachypnea at Primary Triage

被引:51
作者
Bianchi, William [1 ,3 ]
Dugas, Andrea Freyer [1 ]
Hsieh, Yu-Hsiang [1 ]
Saheed, Mustapha [1 ]
Hill, Peter [1 ]
Lindauer, Cathleen [1 ]
Terzis, Andreas [2 ]
Rothman, Richard E. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Emergency Med, Baltimore, MD 21218 USA
[2] Johns Hopkins Univ, Dept Comp Sci, Baltimore, MD 21218 USA
[3] Lake Erie Coll Osteopath Med, Bradenton, FL USA
基金
美国国家科学基金会;
关键词
RESPIRATORY RATE; RELIABILITY;
D O I
10.1016/j.annemergmed.2012.05.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: This study evaluates the accuracy of emergency department (ED) triage respiratory rate measurement using the usual care method and a new electronic respiratory rate sensor (BioHarness, Zephyr Technology Corp.), both compared to a criterion standard measurement. Methods: This is a cross-sectional study with convenience sampling conducted in an urban academic adult ED, including 3 separate respiratory rate measurements performed at ED triage: usual care measurement, electronic BioHarness measurement, and criterion standard measurement. The criterion standard measurement used was defined by the World Health Organization as manual observation or auscultation of respirations for 60 seconds. The resultant usual care and BioHarness measurements were compared with the criterion standard, evaluating accuracy (sensitivity and specificity) for detecting tachypnea, as well as potential systematic biases of usual care and BioHarness measurements using a Bland Altman analysis. Results: Of 191 analyzed patients, 44 presented with tachypnea (>20 breaths/min). Relative to criterion standard measurement, usual care measurement had a sensitivity of 23% (95% confidence interval [CI] 12% to 37%) and specificity of 99% (95% CI 97% to 100%) for tachypnea, whereas BioHamess had a sensitivity of 91% (95% CI 80% to 97%) and specificity of 97% (95% CI 93% to 99%) for tachypnea. Usual care measurements clustered around respiratory rates of 16 and 18 breaths/min (n=144), with poor agreement with criterion standard measurement. Conversely, BioHamess measurement closely tracked criterion standard values over the range of respiratory rates. Conclusion: Current methods of respiratory rate measurement at ED triage are inaccurate. A new electronic respiratory rate sensor, BioHarness, has significantly greater sensitivity for detecting tachypnea versus usual care method of measurement. [Ann Emerg Med. 2013;61:37-43.]
引用
收藏
页码:37 / 43
页数:7
相关论文
共 19 条
[1]  
[Anonymous], 2011, AHRQ Publication
[2]   STRATEGIES FOR IMPROVING POWER IN DIAGNOSTIC-RADIOLOGY RESEARCH [J].
BEAM, CA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) :631-637
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   AMERICAN-COLLEGE OF CHEST PHYSICIANS SOCIETY OF CRITICAL CARE MEDICINE CONSENSUS CONFERENCE - DEFINITIONS FOR SEPSIS AND ORGAN FAILURE AND GUIDELINES FOR THE USE OF INNOVATIVE THERAPIES IN SEPSIS [J].
BONE, RC ;
BALK, RA ;
CERRA, FB ;
DELLINGER, RP ;
FEIN, AM ;
KNAUS, WA ;
SCHEIN, RMH ;
SIBBALD, WJ ;
ABRAMS, JH ;
BERNARD, GR ;
BIONDI, JW ;
CALVIN, JE ;
DEMLING, R ;
FAHEY, PJ ;
FISHER, CJ ;
FRANKLIN, C ;
GORELICK, KJ ;
KELLEY, MA ;
MAKI, DG ;
MARSHALL, JC ;
MERRILL, WW ;
PRIBBLE, JP ;
RACKOW, EC ;
RODELL, TC ;
SHEAGREN, JN ;
SILVER, M ;
SPRUNG, CL ;
STRAUBE, RC ;
TOBIN, MJ ;
TRENHOLME, GM ;
WAGNER, DP ;
WEBB, CD ;
WHERRY, JC ;
WIEDEMANN, HP ;
WORTEL, CH .
CRITICAL CARE MEDICINE, 1992, 20 (06) :864-874
[5]   How good is that agreement? [J].
Byrt, T .
EPIDEMIOLOGY, 1996, 7 (05) :561-561
[6]   CAN WE IMPROVE THE CLINICAL UTILITY OF RESPIRATORY RATE AS A MONITORED VITAL SIGN? [J].
Chen, Liangyou ;
Reisner, Andrew T. ;
Gribok, Andrei ;
McKenna, Thomas M. ;
Reifman, Jaques .
SHOCK, 2009, 31 (06) :574-580
[7]  
Cheng AC, 2008, MED J AUSTRALIA, V189, P531, DOI 10.5694/j.1326-5377.2008.tb02163.x
[8]   Effect of vital signs on triage decisions [J].
Cooper, RJ ;
Schriger, DL ;
Flaherty, HL ;
Lin, EJ ;
Hubbell, KA .
ANNALS OF EMERGENCY MEDICINE, 2002, 39 (03) :223-232
[9]  
Cretikos MA, 2008, MED J AUSTRALIA, V188, P657
[10]   The reliability of vital sign measurements [J].
Edmonds, ZV ;
Mower, WR ;
Lovato, LM ;
Lomeli, R .
ANNALS OF EMERGENCY MEDICINE, 2002, 39 (03) :233-237