Sequential injection sample introduction microfluidic-chip based capillary electrophoresis system

被引:71
作者
Fang, Q [1 ]
Wang, FR [1 ]
Wang, SL [1 ]
Liu, SS [1 ]
Xu, SK [1 ]
Fang, ZL [1 ]
机构
[1] Northeastern Univ, Res Ctr Analyt Sci, Shenyang 110006, Peoples R China
关键词
sequential injection; capillary electrophoresis; microfluidics; microchips; amino acids;
D O I
10.1016/S0003-2670(99)00183-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sequential injection micro-sample introduction system was coupled to a microfluidic-chip based capillary electrophoresis system through a split-flow sampling interface integrated on the micro-chip. The microfluidic system measured 20x70x3 mm in dimension, and was produced using a non-lithographic approach with components readily available in the analytical laboratory. In the H-configuration channel design the horizontal separation channel was a 75 mu m I.D. x 60 mm quartz capillary, with two vertical side arms produced from plastic tubing. The conduits were embedded in silicon elastomer with a planar glass base. Sequential introduction of a series of samples with about 2.5% carryover was achieved at 48 h(-1) throughput with samples containing a mixture of fluorescein isothiocyanate (FITC)-labeled amino acids using SI sample volumes of 3.3 mu l and carrier flow-rate of 2.0 ml min(-1). Baseline separation was achieved for FITC-labeled arginine, phenylalanine, glycine and FITC (laser induced fluorescence detection) in sodium tetraborate buffer (pH 9.2) within 8-80 s, at separation lengths of 25-35 mm and electrical field strengths of 250-1500 V cm(-1), with plate heights in the 0.7-3 mu m range. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 18 条
[1]   An integrated nanoliter DNA analysis device [J].
Burns, MA ;
Johnson, BN ;
Brahmasandra, SN ;
Handique, K ;
Webster, JR ;
Krishnan, M ;
Sammarco, TS ;
Man, PM ;
Jones, D ;
Heldsinger, D ;
Mastrangelo, CH ;
Burke, DT .
SCIENCE, 1998, 282 (5388) :484-487
[2]   Combination of flow injection with capillary electrophoresis. Part 3. On-line sorption column preconcentration capillary electrophoresis system [J].
Chen, HW ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) :135-143
[3]  
Dempsey E, 1997, ANAL CHIM ACTA, V346, P341
[4]   GLASS CHIPS FOR HIGH-SPEED CAPILLARY ELECTROPHORESIS SEPARATIONS WITH SUBMICROMETER PLATE HEIGHTS [J].
EFFENHAUSER, CS ;
MANZ, A ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1993, 65 (19) :2637-2642
[5]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[6]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[7]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932
[8]   HIGH-SPEED SEPARATIONS ON A MICROCHIP [J].
JACOBSON, SC ;
HERGENRODER, R ;
KOUTNY, LB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1114-1118
[9]   MICROCHIP CAPILLARY ELECTROPHORESIS WITH AN INTEGRATED POSTCOLUMN REACTOR [J].
JACOBSON, SC ;
KOUTNY, LB ;
HERGENRODER, R ;
MOORE, AW ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1994, 66 (20) :3472-3476
[10]   Chemical amplification: Continuous-flow PCR on a chip [J].
Kopp, MU ;
de Mello, AJ ;
Manz, A .
SCIENCE, 1998, 280 (5366) :1046-1048