An indirect analytical approach based on ATR-FTIR spectroscopy for determining the FFA content in vegetable oils

被引:5
|
作者
Dong, Yaoyao [1 ]
Shi, Shaoxia [1 ]
Li, Qi [1 ]
Zhang, Lingyan [1 ]
Yu, Xiuzhu [1 ]
机构
[1] Northwest A&F Univ, Coll Food Sci & Engn, 22 Xinong Rd, Yangling 712100, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
FREE FATTY-ACIDS; PH-METRIC DETERMINATION; RAPID-DETERMINATION; GAS-CHROMATOGRAPHY; EDIBLE OILS; VALUES; CHEMOMETRICS; PREDICTION;
D O I
10.1039/d0ra03668d
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we developed a novel approach for determining a free fatty acid (FFA) in vegetable oils using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. FFA was converted to carboxylate species by a reaction with phthalimide potassium salt, and the linear relationship between FFA content and ATR-FTIR peak areas at 1541-1616 cm(-1)(1595 cm(-1)as baseline) was established. Results showed that theR(2)values obtained during calibration and validation were more than 0.99. The calibration method concurred to within +/- 0.035% over the range of 0.4% to 4.0% (quantitative determination of the percentage of FFA in oils, expressed as the percentage of oleic acid). In the calibration model, the root mean square error of prediction was 0.0104, the relative error was less than 0.246% and the relative average deviation was 0.386%, respectively. These indexes demonstrated that the calibration model has great accuracy, high precision and good stability. The indirect method established using ATR-FTIR has the advantages of excellent reproducibility, high exactitude, independent of oil type, simple operation and easy cleaning of the instrument surface. The slope of the verification equation between FFA prediction values and American Oil Chemists' Society's (AOCS) titration method was close to 1,R(2)value was more than 0.99. These indicators suggested that the proposed method and the AOCS method have a good correlation through AOCS titration and ATR-FTIR spectroscopy to determine validation samples parallel. In addition, for comparison, when the AOCS titration and ATR-FTIR spectroscopy methods were used for sample validation, the results indicated that the latter method is more reproducible, highly sensitive and has strong anti-disturbance. Therefore, the ATR-FTIR technique can be applied as a simple, highly sensitive, convenient and timely method for the analysis of FFAs in oils.
引用
收藏
页码:24073 / 24078
页数:6
相关论文
共 36 条
  • [21] Rapid and non-destructive identification of claws using ATR-FTIR spectroscopy-A novel approach in wildlife forensics
    Sharma, Chandra Prakash
    Sharma, Sweety
    Sharma, Vishal
    Singh, Rajinder
    SCIENCE & JUSTICE, 2019, 59 (06) : 622 - 629
  • [22] Characterization of Animal and Vegetable Oil by Attenuated Total Reflectance - Fourier Transform Infrared (ATR-FTIR) Spectroscopy with Supervised Pattern Recognition and Filter Algorithm
    Qiu, Weilun
    Yi, Rongnan
    ANALYTICAL LETTERS, 2024, 57 (02) : 307 - 316
  • [23] Discrimination and analytical profiling of colored printed documents using ATR-FTIR spectroscopy coupled with explorative and predictive statistical analysis: Part I
    Tomar, Anjali
    Yamini
    Gupta, Reeta R.
    Choudhary, Manoj Kumar
    Sachar, Shilpee
    Mehta, S. K.
    Sharma, Shweta
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2024, 322
  • [24] Spectrochemical differentiation of meningioma tumours based on attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy
    Lilo, Taha
    Morais, Camilo L. M.
    Ashton, Katherine M.
    Pardilho, Ana
    Davis, Charles
    Dawson, Timothy P.
    Gurusinghe, Nihal
    Martin, Francis L.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (05) : 1077 - 1086
  • [25] Spectrochemical differentiation of meningioma tumours based on attenuated total reflection Fourier-transform infrared (ATR-FTIR) spectroscopy
    Taha Lilo
    Camilo L. M. Morais
    Katherine M. Ashton
    Ana Pardilho
    Charles Davis
    Timothy P. Dawson
    Nihal Gurusinghe
    Francis L. Martin
    Analytical and Bioanalytical Chemistry, 2020, 412 : 1077 - 1086
  • [26] Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR) Coupled with Chemometrics, to Control the Botanical Authenticity and Quality of Cold-Pressed Functional Oils Commercialized in Romania
    Socaciu, Carmen
    Fetea, Florinela
    Ranga, Floricuta
    Bunea, Andrea
    Dulf, Francisc
    Socaci, Sonia
    Pintea, Adela
    APPLIED SCIENCES-BASEL, 2020, 10 (23): : 1 - 16
  • [27] Prediction of dielectric dissipation factor by ATR-FTIR spectroscopy based on multivariate calibration methods for transformer oil samples in power industry
    Zandbaaf, Shima
    Khorrami, Mohammad Reza Khanmohammadi
    Afshar, Majid Ghahraman
    INFRARED PHYSICS & TECHNOLOGY, 2023, 128
  • [28] Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy coupled with chemometric analysis for detection and quantification of adulteration in lavender and citronella essential oils
    Truzzi, Eleonora
    Marchetti, Lucia
    Bertelli, Davide
    Benvenuti, Stefania
    PHYTOCHEMICAL ANALYSIS, 2021, 32 (06) : 907 - 920
  • [29] Forensic examination of thermal papers using Video Spectral Comparator (VSC) and ATR-FTIR spectroscopy coupled with chemometrics: Non-destructive approach
    Tomar, Anjali
    Gupta, Reeta R.
    Kaur, Amanpreet
    Semwal, J. K.
    Kumar, Sanjeev
    Mehta, S. K.
    Sharma, Shweta
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2021, 260
  • [30] Comparative Blood Profiling Based on ATR-FTIR Spectroscopy and Chemometrics for Differential Diagnosis of Patients with Amyotrophic Lateral Sclerosis-Pilot Study
    Tkachenko, Kateryna
    Gonzalez-Saiz, Jose M.
    Calvo, Ana C.
    Lunetta, Christian
    Osta, Rosario
    Pizarro, Consuelo
    BIOSENSORS-BASEL, 2024, 14 (11):