A Hold-up Time Extending Method for Asymmetrical Half-bridge Converter

被引:0
作者
Jin-Tae, Kim [1 ]
Shanmei, Li [1 ]
机构
[1] Fairchild Korea Semicond Co Ltd, Bucheon, South Korea
来源
PROCEEDINGS OF THE 2011-14TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE 2011) | 2011年
关键词
Converter control; DC power supply; High frequency power converter; Soft switching;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For asymmetric half-bridge converters, one of drawbacks is pretty narrow input voltage range, whose reasons are a leakage inductance for ZVS, its switches configuration and a blocking capacitor for clamping power switches with the input voltage. Therefore a hold-up time is more quite restricted for others. In this paper, it will be analyzed for a voltage conversion ratio of the converter. And a way to extend hold-up time for the converter will be shown. Finally, an asymmetrical half-bridge converter will be tested with 24V/8A of output specification to verify the way.
引用
收藏
页数:7
相关论文
共 6 条
[1]  
Chen WY, 2001, APPL POWER ELECT CO, P703, DOI 10.1109/APEC.2001.912446
[2]  
Guan-Chyun Hsieh, TENCON 2005
[3]  
Lin Bor-Ren, IND TECHN ICIT 2005, P1209
[4]  
Mao Hong, POWER ELECT IEEE T, V19, P947
[5]  
Tolle T., PESC 2011 32 ANN IEE, V1
[6]  
Wen Yangyang, APEC 2005 20 ANN IEE, P1525