Agglomeration of particles by ac corona discharge

被引:1
|
作者
Zukeran, A [1 ]
Ikeda, Y
Ehara, Y
Ito, T
Takahashi, T
Kawakami, H
Takamatsu, T
机构
[1] Musashi Inst Technol, Dept Elect & Elect Engn, Tokyo, Japan
[2] Fuji Elect Co Ltd, Social Syst Div, Fuji, Shizuoka, Japan
关键词
agglomeration; ac corona discharge; electrostatic precipitator; diesel exhaust particles; submicron particles;
D O I
10.1002/(SICI)1520-6416(200001)130:1<30::AID-EEJ5>3.3.CO;2-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Improving the collection efficiency for particles smaller than 1 mu m on every precipitator is important. We sought to improve the collection of these particles on an ESP due to particle agglomeration. Particles are charged by ac corona discharge in a precharger and agglomerated by a dc electric field in an agglomerator downstream of the precharger. Diesel exhaust particles were used as particulate matter for the experiments. The distribution of particle size was measured using a particle counter and a scanning electron microscope. By these methods, particles as small as 0.01 mu m could be counted. Results showed the agglomeration between particles at ac corona discharge operating mode. The concentration of particles smaller than approximately 0.35 mu m decreases, and that of particles larger than approximately 0.35 mu m increases in the agglomerator. The agglomeration rate increases with increasing applied voltage, then saturates. These results may be due to the size distribution and to decrease of concentration by agglomeration. (C) 1999 Scripta Technica.
引用
收藏
页码:30 / 37
页数:8
相关论文
共 50 条
  • [1] Agglomeration of particles by ac corona discharge
    Zukeran, Akinori, 1600, Scripta Technica Inc, New York, NY, United States (130):
  • [2] Influence of Medium Particles on the Corona Discharge Process of AC Conductor
    Liu, Yunpeng
    Wu, Zhenyang
    Zhu, Lei
    Liu, Yang
    INTERNATIONAL CONFERENCE ON ELECTRICAL, CONTROL AND AUTOMATION (ICECA 2014), 2014, : 565 - 571
  • [3] The Influences of Acoustic and Pulsed Corona Discharge Coupling Field on Agglomeration of Monodisperse Fine Particles
    He, Mingchun
    Luo, Zhongyang
    Wang, Haolin
    Fang, Mengxiang
    APPLIED SCIENCES-BASEL, 2020, 10 (03):
  • [4] AC CORONA CHARGING OF PARTICLES
    EHRLICH, RM
    MELCHER, JR
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1987, 23 (01) : 103 - 107
  • [6] EFFECT OF SOOT PARTICLES ON CORONA DISCHARGE
    LIN, CH
    CHAO, BT
    SOO, SL
    AEROSOL SCIENCE AND TECHNOLOGY, 1990, 13 (04) : 434 - 449
  • [7] Electromagnetical emissions of corona discharge for AC voltage
    Kysela, Adam
    PROCEEDINGS OF THE 12TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2011, 2011, : 351 - 353
  • [8] Induced adsorption and agglomeration under bipolar corona discharge to enhance the simultaneous removal of trace mercury and fine particles
    Wang, Jia'nan
    Huang, Wenjun
    Xu, Haomiao
    Wang, Hongbin
    Hong, Qinyuan
    Qu, Zan
    Yan, Naiqiang
    FUEL, 2022, 326
  • [9] Agglomeration and capture of fine particles in the coupling effect of pulsed corona discharge and acoustic wave enhanced by spray droplets
    Luo, Zhongyang
    Chen, Hao
    Wang, Tao
    Zhou, Dong
    Lu, Mengshi
    He, Mingchun
    Fang, Mengxiang
    Cen, Kefa
    POWDER TECHNOLOGY, 2017, 312 : 21 - 28
  • [10] Effects of Acoustic and Pulse Corona Discharge Coupling Field on Agglomeration and Removal of Coal-fired Fine Particles
    He, Mingchun
    Luo, Zhongyang
    Lu, Mengshi
    Liu, Shuxin
    Fang, Mengxiang
    AEROSOL AND AIR QUALITY RESEARCH, 2019, 19 (11) : 2585 - 2596