A comparison of the Airtraq®, McGrath®, and Macintosh laryngoscopes for difficult paediatric intubation: A manikin study

被引:11
作者
Owada, Gen [1 ]
Mihara, Takahiro [1 ,2 ]
Inagawa, Gaku [3 ]
Asakura, Ayako [2 ]
Goto, Takahisa [2 ]
Ka, Koui [1 ]
机构
[1] Kanagawa Childrens Med Ctr, Dept Anaesthesiol, Yokohama, Kanagawa, Japan
[2] Yokohama City Univ, Grad Sch Med, Dept Anaesthesiol & Crit Care Med, Yokohama, Kanagawa, Japan
[3] Yokohama Municipal Citizens Hosp, Dept Anaesthesiol, Yokohama, Kanagawa, Japan
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
TRACHEAL INTUBATION; MANAGEMENT; PERSONNEL; TRIAL;
D O I
10.1371/journal.pone.0171889
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background The efficacy of devices for difficult intubation in paediatric patients, especially with a Cormack-Lehane grade 4 view, has yet to be established. We compared intubating parameters among three devices (the Airtraq (R), McGrath (R), and Macintosh laryngoscopes). Methods This study is a randomised cross-over trial. Participants were 20 anaesthetists. Each device was tested three times using a paediatric manikin with a Cormack-Lehane grade 4 view. The order to use each device was randomised by a computer-generated random sequence. The primary endpoint was the rate of successful intubation. Secondary endpoints included the time taken to intubate, percentage of glottic opening score, and severity of potential dental trauma. Results The successful intubation rates of the Airtraq (R), McGrath (R), and Macintosh laryngoscopes were 100%, 72%, and 45%, respectively. The risk ratio of the success rates of Airtraq (R) compared with McGrath (R) and Macintosh laryngoscopes were 1.40 (95% CI; 1.19-1.64, P < 0.001) and 2.22 (95% CI; 1.68-2.94, P < 0.001), respectively. The modified Cormack-Lehane grade and percentage of the glottic opening score were better for the Airtraq (R) than for the other devices. The dental trauma score was lower for the Airtraq (R) than for the other devices. There were no significant differences in the intubation time among the groups. Conclusions The Airtraq (R) had higher success rate, had better visibility, and was associated with less dental trauma than the other devices in a difficult paediatric intubation model with a Cormack-Lehane grade 4 view.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of McGRATH MAC and Macintosh laryngoscopes for double-lumen endotracheal tube intubation by anesthesia residents: a prospective randomized clinical trial
    Kido, Haruki
    Komasawa, Nobuyasu
    Matsunami, Sayuri
    Kusaka, Yusuke
    Minami, Toshiaki
    JOURNAL OF CLINICAL ANESTHESIA, 2015, 27 (06) : 476 - 480
  • [42] Comparison of the Macintosh, McCoy, Airtraq laryngoscopes and the intubating laryngeal mask airway in a difficult airway with manual in-line stabilisation A cross-over simulation-based study
    Sherren, Peter B.
    Kong, Ming-Li
    Chang, Serene
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2013, 30 (09) : 544 - 549
  • [43] Macintosh laryngoscope and i-view™ and C-MAC® video laryngoscopes for tracheal intubation with an aerosol box: a randomized crossover manikin study
    Nakanishi, Toshiyuki
    Sento, Yoshiki
    Kamimura, Yuji
    Sobue, Kazuya
    JA CLINICAL REPORTS, 2021, 7 (01)
  • [44] Endobronchial Intubation With the King Vision® and McGrath® Laryngoscopes in Simulated Easy and Difficult Airways by Novices (eKingMath)
    Khidr, Alaa M.
    Masoudi, Jumana
    AlAboud, Sarah
    Alshahrani, Mashael
    Bokhari, Aziza
    Sorbello, Massimiliano
    Zdravkovic, Ivana
    Khalil, Mohamed A.
    Al Shadowy, Saeed
    Al Ghamdi, Talal
    Al'ghamdi, Abdulmohsen
    Fallatah, Summayah
    El Tahan, Mohamed R.
    SEMINARS IN CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 27 (03) : 181 - 198
  • [45] Comparison between intubation through ILMA and Airtraq, in different non-conventional patient positions: a manikin study
    Grosomanidis, V.
    Amaniti, E.
    Pourzitaki, Ch
    Fyntanidou, V.
    Mouratidis, K.
    Vasilakos, D.
    EMERGENCY MEDICINE JOURNAL, 2012, 29 (01) : 32 - 36
  • [46] A comparison of McGrath MACA® and standard direct laryngoscopy in simulated immobilized cervical spine pediatric intubation: a manikin study
    Madziala, Marcin
    Smereka, Jacek
    Dabrowski, Marek
    Leung, Steve
    Ruetzler, Kurt
    Szarpak, Lukasz
    EUROPEAN JOURNAL OF PEDIATRICS, 2017, 176 (06) : 779 - 786
  • [47] Tracheal intubation for a difficult airway using Airway scope®, KingVision® and McGRATH®: a comparative manikin study of inexperienced personnel
    J Itai
    Y Tanabe
    T Nishida
    T Inagawa
    Y Torikoshi
    Y Kida
    T Tamura
    K Ota
    T Otani
    T Sadamori
    K Une
    R Tsumura
    Y Iwasaki
    N Hirohashi
    K Tanigawal
    Critical Care, 17 (Suppl 2):
  • [48] Comparison of Airtraq™ video-laryngoscope and Macintosh laryngoscope for tracheal intubation in adults—a randomised study
    Seema Meena
    Sujata Chaudhary
    Rashmi Salhotra
    Swati Bharti
    Bismanjeet Kaur Khurana
    Ain-Shams Journal of Anesthesiology, 15
  • [49] Comparison of McGrath, Pentax, and Macintosh laryngoscope in normal and cervical immobilized manikin by novices: a randomized crossover trial
    Yi, In Kyong
    Kwak, Hyun Jeong
    Lee, Kyung Cheon
    Lee, Ji Hyea
    Min, Sang Kee
    Kim, Jong Yeop
    EUROPEAN JOURNAL OF MEDICAL RESEARCH, 2020, 25 (01)
  • [50] Rational comparison of tracheal intubation with direct and indirect laryngoscopes in a simulated trapped manikin
    Liu, Kun-Peng
    Cheng, Yi
    Xue, Fu-Shan
    Li, Rui-Ping
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2012, 29 (10) : 496 - 497