A comparison of the Airtraq®, McGrath®, and Macintosh laryngoscopes for difficult paediatric intubation: A manikin study

被引:11
作者
Owada, Gen [1 ]
Mihara, Takahiro [1 ,2 ]
Inagawa, Gaku [3 ]
Asakura, Ayako [2 ]
Goto, Takahisa [2 ]
Ka, Koui [1 ]
机构
[1] Kanagawa Childrens Med Ctr, Dept Anaesthesiol, Yokohama, Kanagawa, Japan
[2] Yokohama City Univ, Grad Sch Med, Dept Anaesthesiol & Crit Care Med, Yokohama, Kanagawa, Japan
[3] Yokohama Municipal Citizens Hosp, Dept Anaesthesiol, Yokohama, Kanagawa, Japan
来源
PLOS ONE | 2017年 / 12卷 / 02期
关键词
TRACHEAL INTUBATION; MANAGEMENT; PERSONNEL; TRIAL;
D O I
10.1371/journal.pone.0171889
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background The efficacy of devices for difficult intubation in paediatric patients, especially with a Cormack-Lehane grade 4 view, has yet to be established. We compared intubating parameters among three devices (the Airtraq (R), McGrath (R), and Macintosh laryngoscopes). Methods This study is a randomised cross-over trial. Participants were 20 anaesthetists. Each device was tested three times using a paediatric manikin with a Cormack-Lehane grade 4 view. The order to use each device was randomised by a computer-generated random sequence. The primary endpoint was the rate of successful intubation. Secondary endpoints included the time taken to intubate, percentage of glottic opening score, and severity of potential dental trauma. Results The successful intubation rates of the Airtraq (R), McGrath (R), and Macintosh laryngoscopes were 100%, 72%, and 45%, respectively. The risk ratio of the success rates of Airtraq (R) compared with McGrath (R) and Macintosh laryngoscopes were 1.40 (95% CI; 1.19-1.64, P < 0.001) and 2.22 (95% CI; 1.68-2.94, P < 0.001), respectively. The modified Cormack-Lehane grade and percentage of the glottic opening score were better for the Airtraq (R) than for the other devices. The dental trauma score was lower for the Airtraq (R) than for the other devices. There were no significant differences in the intubation time among the groups. Conclusions The Airtraq (R) had higher success rate, had better visibility, and was associated with less dental trauma than the other devices in a difficult paediatric intubation model with a Cormack-Lehane grade 4 view.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] McGrath® versus Macintosh laryngoscopes on hemodynamic response to intubation in elderly patients: a randomized clinical trial
    Ketata, Salma
    Fourati, Mahdi
    Derbel, Rahma
    Keskes, Mariem
    Bouzid, Karim
    Zouche, Imen
    Sallemi, Moncef
    Kallel, Souha
    Fendri, Sami
    Zouari, Amine
    Cheikhrouhou, Hichem
    PAN AFRICAN MEDICAL JOURNAL, 2023, 45
  • [32] COMPARISON OF HEMODYNAMIC RESPONSE TO TRACHEAL INTUBATION WITH MACINTOSH AND MCCOY LARYNGOSCOPES
    Jitendra, Mukta
    Sharma, Sonal
    Katoch, Madan
    Gulati, Smriti
    Gupta, Heena
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2015, 4 (50): : 8676 - 8684
  • [33] A COMPARISON OF TRACHEAL INTUBATION USING THE AIRTRAQ AND THE MACINTOSH LARYNGOSCOPE- A PROSPECTIVE STUDY
    Gandhi, Ravindra
    Attar, Asha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2019, 8 (28): : 2283 - 2287
  • [34] A comparison of GlideScope and Macintosh laryngoscopes for endotracheal intubation performed by nurses
    Aleksandrowicz, Sebastian
    Szarpak, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2016, 34 (10) : 2041 - 2041
  • [35] A comparison of the Trachway intubating stylet and the Macintosh laryngoscope in tracheal intubation: a manikin study
    Kuo-Chuan Hung
    Ping-Heng Tan
    Victor Chia-Hsiang Lin
    Hao-Kuang Wang
    Hung-Shu Chen
    Journal of Anesthesia, 2013, 27 : 205 - 210
  • [36] Comparison of the Glidescope® and Pentax AWS® laryngoscopes to the Macintosh laryngoscope for use by Advanced Paramedics in easy and simulated difficult intubation
    Nasim S.
    Maharaj C.H.
    Malik M.A.
    O'Donnell J.
    Higgins B.D.
    Laffey J.G.
    BMC Emergency Medicine, 9 (1)
  • [37] A comparison of the Trachway intubating stylet and the Macintosh laryngoscope in tracheal intubation: a manikin study
    Hung, Kuo-Chuan
    Tan, Ping-Heng
    Lin, Victor Chia-Hsiang
    Wang, Hao-Kuang
    Chen, Hung-Shu
    JOURNAL OF ANESTHESIA, 2013, 27 (02) : 205 - 210
  • [38] Randomized controlled trial of the Pentax AWS®, Glidescope®, and Macintosh laryngoscopes in predicted difficult intubation
    Malik, M. A.
    Subramaniam, R.
    Maharaj, C. H.
    Harte, B. H.
    Laffey, J. G.
    BRITISH JOURNAL OF ANAESTHESIA, 2009, 103 (05) : 761 - 768
  • [39] Comparative evaluation of Airtraq™ and GlideScope® videolaryngoscopes for difficult pediatric intubation in a Pierre Robin manikin
    Desai, Neel
    Johnson, Mae
    Priddis, Kat
    Ray, Samiran
    Chigaru, Linda
    EUROPEAN JOURNAL OF PEDIATRICS, 2019, 178 (07) : 1105 - 1111
  • [40] Comparison of intubation through the McGrath MAC, GlideScope, AirTraq, and Miller Laryngoscope by paramedics during child CPR: a randomized crossover manikin trial
    Szarpak, Lukasz
    Karczewska, Katarzyna
    Evrin, Togay
    Kurowski, Andrzej
    Czyzewski, Lukasz
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2015, 33 (07) : 946 - 950