Bubble dissolution in horizontal turbulent bubbly flow in domestic central heating system

被引:9
作者
Ge, Y. T. [1 ]
Fsadni, A. M. [1 ]
Wang, H. S. [2 ]
机构
[1] Brunel Univ, Sch Engn & Design, Uxbridge UB8 3PH, Middx, England
[2] Queen Mary Univ London, Sch Engn & Mat Sci, London E1 4NS, England
基金
英国工程与自然科学研究理事会;
关键词
Bubble dissolution; Horizontal bubbly flow; Central heating systems; Experiment; Modelling; MASS-TRANSFER; NUCLEATION; SURFACE;
D O I
10.1016/j.apenergy.2013.03.055
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In a domestic central heating system, the phenomenon of microbubble nucleation and detachment on the surface of a boiler heat exchanger finds its origins in the high surface temperature of the wall and consequential localised super saturation conditions. If the surrounding bulk fluid is at under-saturated conditions, then after exiting the boiler, the occurrence is followed by bubbly flow and bubble dissolution. A comprehensive understanding of the fundamentals of bubble dissolution in such a domestic wet central heating system is essential for an enhanced deaeration technique that would consequently improve system performance. In this paper, the bubble dissolution rate along a horizontal pipe was investigated experimentally at different operating conditions in a purpose built test rig of a standard domestic central heating system. A high speed camera was used to measure the bubble size at different depths of focal plane using two square sectioned sight glasses at two stations, spaced 2.2 m apart. A dynamic model for bubble dissolution in horizontal bubbly flow has been developed and compared with experimental data. The effects of several important operating and structural parameters such as saturation ratio, velocity, temperature, pressure of the bulk liquid flow, initial bubble size and pipe inside diameter on the bubble dissolution were thus examined using the model. This model provides a useful tool for understanding bubble behaviours in central heating systems and optimising the system efficiency. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:477 / 485
页数:9
相关论文
共 26 条
[1]  
Ahmed T., 2003, J ENVIRON SYST, V29, P101, DOI [10.2190/9402-N69Y-KHGM-YE9N, DOI 10.2190/9402-N69Y-KHGM-YE9N]
[2]   MOTION OF VAPOR BUBBLES IN SUBCOOLED HEATED CHANNEL. [J].
Akiyama, Mamoru ;
Tachibana, Fujio .
Bulletin of the JSME, 1974, 17 (104) :241-247
[3]  
[Anonymous], 2010, IM PROPL START UP GU
[4]  
AVDEEV AA, 1988, HIGH TEMP+, V26, P214
[5]  
Battino R., 1982, NITROGEN AIR SOLUBIL
[6]   DISSOLVING OF STATIONARY GAS BUBBLES IN A LIQUID [J].
CABLE, M .
CHEMICAL ENGINEERING SCIENCE, 1967, 22 (11) :1393-&
[7]   THE INFLUENCE OF SURFACE-TENSION ON THE DIFFUSION-CONTROLLED GROWTH OR DISSOLUTION OF SPHERICAL GAS-BUBBLES [J].
CABLE, M ;
FRADE, JR .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 1988, 420 (1859) :247-265
[8]   Condensing boiler applications in the process industry [J].
Chen, Qun ;
Finney, Karen ;
Li, Hanning ;
Zhang, Xiaohui ;
Zhou, Jue ;
Sharifi, Vida ;
Swithenbank, Jim .
APPLIED ENERGY, 2012, 89 (01) :30-36
[9]   Performance analysis of a proposed solar assisted ground coupled heat pump system [J].
Chen, Xi ;
Yang, Hongxing .
APPLIED ENERGY, 2012, 97 :888-896
[10]  
Coleman H.W., 1999, Experimentation and Uncertainty Analysis for Engineers