Design of an XAFS beamline at the Photon Factory: possibilities of bent conical mirrors

被引:78
作者
Masaharu, N [1 ]
Atsushi, K [1 ]
机构
[1] KEK, Inst Mat Struct Sci, Photon Factory, Tsukuba, Ibaraki 3050801, Japan
关键词
XAFS; beamline; bent conical mirror; focus;
D O I
10.1107/S0909049598016823
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new XAFS beamline which uses a pair of bent conical mirrors for collimation and focusing is under construction. A double crystal monochromator is placed between the two mirrors. This beamline is to provide high flux without sacrificing the energy resolution. Ray-trace results indicate that a bent conical mirror is not only a good approximation of a rotating paraboloidal, but also that of rotating ellipsoidal, minor.
引用
收藏
页码:182 / 184
页数:3
相关论文
共 9 条
[1]  
HEALD SM, 1982, NUCL INSTRUM METHODS, V195, P59, DOI 10.1016/0029-554X(82)90757-1
[2]   ELLIPSOIDAL AND BENT CYLINDRICAL CONDENSING MIRRORS FOR SYNCHROTRON RADIATION [J].
HOWELL, JA ;
HOROWITZ, P .
NUCLEAR INSTRUMENTS & METHODS, 1975, 125 (02) :225-230
[3]   IMPROVEMENT OF A SAGITTALLY FOCUSING DOUBLE-CRYSTAL MONOCHROMATOR [J].
KOYAMA, A ;
NOMURA, M ;
KAWATA, H ;
IWAZUMI, T ;
SATO, M ;
MATSUSHITA, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :916-919
[4]   SAGITTALLY FOCUSING DOUBLE-CRYSTAL MONOCHROMATOR WITH CONSTANT EXIT BEAM HEIGHT AT THE PHOTON FACTORY [J].
MATSUSHITA, T ;
ISHIKAWA, T ;
OYANAGI, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1986, 246 (1-3) :377-379
[5]  
MURAMATSU Y, 1987, 8710 KEK, P1
[6]  
NOMURA M, 1991, 911 KEK, P1
[7]  
NOMURA M, 1996, 9515 KEK, P1
[8]   DESIGN OF AN X-RAY BEAMLINE ON A BENDING MAGNET AT THE ESRF FOR MAGNETIC AND HIGH-RESOLUTION DIFFRACTION [J].
PAUL, DF ;
COOPER, MJ ;
STIRLING, WG .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1741-1744
[9]   X-RAY MONOCHROMATOR GEOMETRY FOR FOCUSING SYNCHROTRON RADIATION ABOVE 10 KEV [J].
SPARKS, CJ ;
BORIE, BS ;
HASTINGS, JB .
NUCLEAR INSTRUMENTS & METHODS, 1980, 172 (1-2) :237-242