Predictive modeling in Clostridium acetobutylicum fermentations employing Raman spectroscopy and multivariate data analysis for real-time culture monitoring

被引:4
|
作者
Zu, Theresah N. K. [1 ]
Liu, Sanchao [1 ]
Germane, Katherine L. [1 ]
Servinsky, Matthew D. [1 ]
Gerlach, Elliot S. [1 ]
Mackie, David M. [1 ]
Sund, Christian J. [1 ]
机构
[1] US Army, Res Lab, 2800 Powder Mill Rd, Adelphi, MD 20783 USA
来源
SMART BIOMEDICAL AND PHYSIOLOGICAL SENSOR TECHNOLOGY XIII | 2016年 / 9863卷
关键词
Raman spectroscopy; chemometrics; MVDA; predictive modeling; Clostridium; fermentation; real-time monitoring; ESCHERICHIA-COLI; SPECTRA; ACIDS;
D O I
10.1117/12.2228545
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The coupling of optical fibers with Raman instrumentation has proven to be effective for real-time monitoring of chemical reactions and fermentations when combined with multivariate statistical data analysis. Raman spectroscopy is relatively fast, with little interference from the water peak present in fermentation media. Medical research has explored this technique for analysis of mammalian cultures for potential diagnosis of some cancers. Other organisms studied via this route include Escherichia coli, Saccharomyces cerevisiae, and some Bacillus sp., though very little work has been performed on Clostridium acetobutylicum cultures. C. acetobutylicum is a gram-positive anaerobic bacterium, which is highly sought after due to its ability to use a broad spectrum of substrates and produce useful byproducts through the well-known Acetone-Butanol-Ethanol (ABE) fermentation. In this work, real-time Raman data was acquired from C. acetobutylicum cultures grown on glucose. Samples were collected concurrently for comparative off-line product analysis. Partial-least squares (PLS) models were built both for agitated cultures and for static cultures from both datasets. Media components and metabolites monitored include glucose, butyric acid, acetic acid, and butanol. Models were cross-validated with independent datasets. Experiments with agitation were more favorable for modeling with goodness of fit (QY) values of 0.99 and goodness of prediction (Q(2)Y) values of 0.98. Static experiments did not model as well as agitated experiments. Raman results showed the static experiments were chaotic, especially during and shortly after manual sampling.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Improving Raman-Based Models for Real-Time Monitoring the CHO Cell Culture Process with Effective Variable Selection Strategies
    Dong, Xiaoxiao
    Yan, Xu
    Qu, Haibin
    APPLIED SCIENCES-BASEL, 2024, 14 (19):
  • [32] Multivariate statistical process control (MSPC) using Raman spectroscopy for in-line culture cell monitoring considering time-varying batches synchronized with correlation optimized warping (COW)
    liu, Ya-Juan
    Andre, Silvere
    Cristau, Lydia Saint
    Lagresle, Sylvain
    Hannas, Zahia
    Calvosa, Eric
    Devos, Olivier
    Duponchel, Ludovic
    ANALYTICA CHIMICA ACTA, 2017, 952 : 9 - 17
  • [33] Real-Time Monitoring and Data Analysis of an Active Landslide in the Three Gorges Reservoir
    Huang, Haifeng
    Yi, Wu
    Yi, Qinglin
    Lu, Shuqiang
    ENGINEERING GEOLOGY FOR SOCIETY AND TERRITORY, VOL 2: LANDSLIDE PROCESSES, 2015, : 1433 - 1436
  • [34] Real-time monitoring of chromatic and phenolic dynamics of vinification employing UV-Vis spectroscopy, Python']Python and chemometrics
    Liu, Caiyun
    Gao, Siye
    Ma, Jialin
    Lu, Yongliang
    Prejano, Mario
    Li, Yunkui
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2024, 132
  • [35] Application of Raman spectroscopy to real-time monitoring of CO2 capture at PACT pilot plant; Part 1: Plant operational data
    Akram M.
    Jinadasa M.H.W.N.
    Tait P.
    Lucquiaud M.
    Milkowski K.
    Szuhanszki J.
    Jens K.-J.
    Halstensen M.
    Pourkashanian M.
    International Journal of Greenhouse Gas Control, 2020, 95
  • [36] Automatic real-time calibration, assessment, and maintenance of generic Raman models for online monitoring of cell culture processes
    Tulsyan, Aditya
    Wang, Tony
    Schorner, Gregg
    Khodabandehlou, Hamid
    Coufal, Myra
    Undey, Cenk
    BIOTECHNOLOGY AND BIOENGINEERING, 2020, 117 (02) : 406 - 416
  • [37] Protein phosphorylation reagent concentration curves via Raman Spectroscopy for real-time reaction monitoring in a microfluidic reactor
    Casey, Abigail H. M.
    Chusan, Nyia E.
    Campbell, Caroline A.
    Triplett, Gregory E.
    BIOSENSING AND NANOMEDICINE XII, 2019, 11087
  • [38] Real-time monitoring of calcium sulfate scale removal from RO desalination membranes using Raman spectroscopy
    Park, Danielle J.
    Supekar, Omkar D.
    Greenberg, Alan R.
    Gopinath, Juliet T.
    Bright, Victor M.
    DESALINATION, 2021, 497
  • [39] Real-time monitoring for blending uniformity of trimebutine CR tablets using near-infrared and Raman spectroscopy
    Woo, Young-Ah
    ANALYTICAL SCIENCE AND TECHNOLOGY, 2011, 24 (06) : 519 - 526
  • [40] Real-Time Monitoring of Aqueous Organic Reduction Reactions Using Ex Situ Fiber Optic Raman Spectroscopy
    Amberchan, Gabriella
    Allen, A' Lester
    Golden, Josh H.
    Singaram, Bakthan
    Zhang, Jin Z.
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2021, 9 (17) : 6068 - 6078