A Multi-Channel Calibration Method for Multi-Filter Rotating Shadow-band Radiometer

被引:5
|
作者
Chen, Maosi [1 ]
Davis, John [1 ]
Tang, Hongzhao [1 ]
Gao, Zhiqiang [1 ]
Gao, Wei [1 ]
机构
[1] Colorado State Univ, USDA UV B Monitoring & Res Program, Nat Resource Ecol Lab, Ft Collins, CO 80521 USA
关键词
MFRSR; Angstrom Law; Langley Analysis; Multi-Channel Calibration; CONDOR; Non-Linear Optimization; ULTRAVIOLET-B RADIATION; OPTICAL DEPTH; URBAN;
D O I
10.1117/12.929454
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
In order to improve the accuracy of solar radiation related parameters' for crop modeling, a new calibration method (Multi-Channel Calibration) for Multi-Filter Rotating Shadow-band Radiometer (MFRSR) is proposed. It uses the Angstrom Law that links aerosol optical depth (AOD) at multiple wavelengths as the primary constraint. It also uses the bi-channel Langley Regression to provide an additional constraint. Starting with any initial guess of calibration coefficient (V-0) at 870 nm, two consecutive steps, both involves calling trust region based non-linear optimization module (CONDOR), are implemented to solve (1) the intermediate parameter Angstrom coefficient and the set of biased V-0s at other channels corresponding to the initial one at 870 nm channel; and (2) the final V-0s of all permissible channels. The result shows that Unlike Langley method, the Multi-Channel Calibration method return V-0 at all permissible channels. Besides, the new method can converge to the same (less than 0.5%) final V-0s with the starting guess in a wide range. Most important, the comparison between AODs derived from those final V-0s and those of AERONET sunphotometers suggests the upper limit of the error of those final V-0s is less than 1.03%, which is a great improvement over the Langley V-0s (7.45%).
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Application of a multi-filter shadowband radiometer and microwave radiometer for ground based evaluation of aerosol-cloud interactions
    Gross, Barry
    Cordero, Lina
    He, Julia
    Madhavan, Bomidi
    Moshary, Fred
    Ahmed, Sam
    REMOTE SENSING OF CLOUDS AND THE ATMOSPHERE XVI, 2011, 8177
  • [42] Multi-channel Iterative Dereverberation based on Codebook Constrained Iterative Multi-channel Wiener Filter
    Ajay, S.
    Sreenivas, T. V.
    11TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION 2010 (INTERSPEECH 2010), VOLS 1-2, 2010, : 981 - 984
  • [43] Comparison of column ozone retrievals obtained by UV multifilter rotating shadow-band radiometer with those from Brewer and Dobson spectrophotometers
    Tree, R
    Slusser, J
    ULTRAVIOLET GROUND- AND SPACE-BASED MEASUREMENTS, MODELS, AND EFFECTS IV, 2004, 5545 : 81 - 89
  • [44] INVESTIGATIONS ON THE INTERNAL CALIBRATION OF MULTI-CHANNEL SAR
    Younis, M.
    Rommel, T.
    de Almeida, F.
    Huber, S.
    Martone, M.
    Villano, M.
    Krieger, G.
    2017 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS), 2017, : 5386 - 5389
  • [45] Multi-Channel Target Shadow Detection in GPS FSR
    Kabakchiev, Hristo
    Garvanov, Ivan
    Behar, Vera
    Kabakchieva, Dorina
    Kabakchiev, Kalin
    Rohling, Hermann
    Kulpa, Krzysztof
    Yarovoy, Alexander
    CYBERNETICS AND INFORMATION TECHNOLOGIES, 2019, 19 (01) : 116 - 132
  • [46] Multi-Channel Radiometer Based on Bandwidth Synthetic to Improve the Sensitivity
    Li, Daotong
    Zhang, Yonghong
    Song, Kaijun
    Fan, Yong
    2015 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM) PROCEEDINGS, 2015, : 297 - 297
  • [47] MULTI-CHANNEL CORRELATOR ARRAY-FED MICROWAVE RADIOMETER
    Piepmeier, Jeffrey R.
    Mahnad, Ali
    De Amici, Giovanni
    Peng, Jinzheng
    Jordan, Jared
    Vanhille, Ken
    Holmes, Thomas
    Racette, Paul
    2019 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM (IGARSS 2019), 2019, : 8419 - 8422
  • [48] Thermal control design of a multi-channel scanning imagery radiometer
    Jiang, Shichen
    Hu, Bingting
    Xu, Tao
    Wang, Ganquan
    OPTICAL DESIGN AND TESTING V, 2012, 8557
  • [49] Multi-channel Heterodyne Radiometer on HT-7 Tokamak
    A. Ti
    B. L. Ling
    Q. S. Fei
    X. Gao
    International Journal of Infrared and Millimeter Waves, 2007, 28 : 243 - 249
  • [50] Multi-channel heterodyne radiometer on HT-7 tokamak
    Ti, A.
    Ling, B. L.
    Fei, Q. S.
    Gao, X.
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 2007, 28 (03): : 243 - 249