A Multi-Channel Calibration Method for Multi-Filter Rotating Shadow-band Radiometer

被引:5
|
作者
Chen, Maosi [1 ]
Davis, John [1 ]
Tang, Hongzhao [1 ]
Gao, Zhiqiang [1 ]
Gao, Wei [1 ]
机构
[1] Colorado State Univ, USDA UV B Monitoring & Res Program, Nat Resource Ecol Lab, Ft Collins, CO 80521 USA
关键词
MFRSR; Angstrom Law; Langley Analysis; Multi-Channel Calibration; CONDOR; Non-Linear Optimization; ULTRAVIOLET-B RADIATION; OPTICAL DEPTH; URBAN;
D O I
10.1117/12.929454
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
In order to improve the accuracy of solar radiation related parameters' for crop modeling, a new calibration method (Multi-Channel Calibration) for Multi-Filter Rotating Shadow-band Radiometer (MFRSR) is proposed. It uses the Angstrom Law that links aerosol optical depth (AOD) at multiple wavelengths as the primary constraint. It also uses the bi-channel Langley Regression to provide an additional constraint. Starting with any initial guess of calibration coefficient (V-0) at 870 nm, two consecutive steps, both involves calling trust region based non-linear optimization module (CONDOR), are implemented to solve (1) the intermediate parameter Angstrom coefficient and the set of biased V-0s at other channels corresponding to the initial one at 870 nm channel; and (2) the final V-0s of all permissible channels. The result shows that Unlike Langley method, the Multi-Channel Calibration method return V-0 at all permissible channels. Besides, the new method can converge to the same (less than 0.5%) final V-0s with the starting guess in a wide range. Most important, the comparison between AODs derived from those final V-0s and those of AERONET sunphotometers suggests the upper limit of the error of those final V-0s is less than 1.03%, which is a great improvement over the Langley V-0s (7.45%).
引用
收藏
页数:14
相关论文
共 50 条
  • [21] A multi-channel microwave radiometer uses reference averaging for calibration: Precision approaches that of a total power radiometer
    Racette, P
    Triesky, M
    Jones, D
    IGARSS '98 - 1998 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, PROCEEDINGS VOLS 1-5: SENSING AND MANAGING THE ENVIRONMENT, 1998, : 1695 - 1697
  • [22] Method of Multi-Channel Calibration for Digital Array Radar
    Li, Weixing
    Lin, Jianzhi
    Wang, Weihua
    Wang, Yasen
    Chen, Zengping
    2015 12TH EUROPEAN RADAR CONFERENCE (EURAD), 2015, : 533 - 536
  • [23] Total ozone column measurements using an ultraviolet multi-filter radiometer
    Raptis, P. I.
    Kazadzis, S.
    Eleftheratos, K.
    Kosmopoulos, P.
    Amiridis, V.
    Helmis, C.
    Zerefos, C.
    INTERNATIONAL JOURNAL OF REMOTE SENSING, 2015, 36 (17) : 4469 - 4482
  • [24] A geostationary orbit microwave multi-channel radiometer
    Zhou, Weilai
    Lv, Rongchuan
    Li, Hao
    Li, Yinan
    Dou, Haofeng
    He, Zheng
    Shen, Shangyu
    Gao, Wenyu
    Ren, He
    Zhang, Long
    Jin, Liang
    FRONTIERS IN PHYSICS, 2023, 11
  • [25] Improving the mean and uncertainty of ultraviolet multi-filter rotating shadowband radiometer in situ calibration factors: utilizing Gaussian process regression with a new method to estimate dynamic input uncertainty
    Chen, Maosi
    Sun, Zhibin
    Davis, John M.
    Liu, Yan-An
    Corr, Chelsea A.
    Gao, Wei
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2019, 12 (02) : 935 - 953
  • [26] Comparison of irradiance measurements made with the multi-filter rotating shadowband radiometer and first-class thermopile radiometers
    Zhou, C
    Michalsky, J
    Harrison, L
    SOLAR ENERGY, 1995, 55 (06) : 487 - 491
  • [27] Remote sensing of atmospheric aerosols, ozone, nitrogen dioxide and water vapor by means of multi-filter rotating shadowband radiometer
    Alexandrov, MD
    Lacis, AA
    Carlson, BE
    Cairns, B
    IRS 2000: CURRENT PROBLEMS IN ATMOSPHERIC RADIATION, 2001, : 855 - 858
  • [28] Multi-channel magnetocardiogardiography system calibration
    Zhang Yong-Sheng
    Qiu Yang
    Zhang Chao-Xiang
    Li Hua
    Zhang Shu-Lin
    Wang Yong-Liang
    Xu Xiao-Feng
    Ding Hong-Sheng
    Kong Xiang-Yan
    ACTA PHYSICA SINICA, 2014, 63 (22)
  • [29] Sampling Time Calibration Method for Multi-Channel Interleaved ADCs
    Leuciuc, Adrian
    2017 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2017, : 108 - 111
  • [30] Quantifying multi-channel receiver calibration
    Frazer, GJ
    Abramovich, YI
    SAM2002: IEEE SENSOR ARRAY AND MULTICHANNEL SIGNAL PROCESSING WORKSHOP PROCEEDINGS, 2002, : 561 - 564