Performance characteristics of ejector expander transcritical CO2 refrigeration cycle

被引:29
|
作者
Ersoy, H. Kursad [1 ]
Bilir, Nagihan [1 ]
机构
[1] Selcuk Univ, Dept Mech Engn, Fac Engn & Architecture, TR-42250 Konya, Turkey
关键词
Suction nozzle; pressure drop; ejector; expansion; turbine; coefficient of performance; exergy; 2-PHASE EJECTOR; EXERGY;
D O I
10.1177/0957650912446547
中图分类号
O414.1 [热力学];
学科分类号
摘要
The effects on the performance of the basic CO2 refrigeration cycle when using an ejector as the expander to recover expansion work were investigated. A two-phase constant area ejector flow model was used in the ejector analysis. The coefficient of cooling performance and gas cooler pressure that yielded the maximum exergy efficiency, suction nozzle pressure drop, and optimum values for the ejector area ratio were determined for various evaporator and gas cooler outlet temperatures. Parametric studies were performed using engineering equation solver. The suction nozzle pressure drop had a significant effect on the ejector area ratio, coefficient of cooling performance, and exergy efficiency. It is necessary to design an ejector with the optimum area ratio to achieve the optimum pressure drop and maximum performance. Cycle that use the ejector as an expander always has higher coefficient of performance and exergy efficiency than conventional cycle under any operating condition. The irreversibility decreases compared to the classic refrigeration cycle when the ejector or turbine are used as an expander. The analysis results showed that - under a gas cooler pressure of 9.5 MPa, gas cooler outlet temperature of 40 degrees C, evaporator temperature of 5 degrees C, and cooling capacity of 3.5kW - the total irreversibility of the ejector system was lower than those of the basic and turbine expander systems by 39.1% and 5.46%, respectively.
引用
收藏
页码:623 / 635
页数:13
相关论文
共 50 条
  • [21] Cycle improvements to ejector-expansion transcritical CO2 two-stage refrigeration cycle
    Yari, M.
    Sirousazar, M.
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2008, 32 (07) : 677 - 687
  • [22] Thermodynamic and exergoeconomic performance assessment of a SOFC/GT cogeneration system integrating transcritical CO2 cycle and ejector refrigeration cycle
    Xu, Chaoyi
    Ye, Jingjing
    Jie, Hao
    Liao, Jiawei
    Teng, Haowen
    Hong, Weirong
    APPLIED THERMAL ENGINEERING, 2025, 270
  • [23] Thermodynamic Analysis of Transcritical CO2 Ejector Expansion Refrigeration Cycle with Dedicated Mechanical Subcooling
    Fu, Ruansong
    Wang, Jinhui
    Zheng, Minfeng
    Yu, Kaihong
    Liu, Xi
    Li, Xuelai
    ENTROPY, 2019, 21 (09)
  • [24] Thermodynamic and environment analysis of a modified transcritical CO2 refrigeration cycle integrated with ejector and subcooler
    Zou, Lingeng
    Liu, Ye
    Yu, Jianlin
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2025, 173 : 123 - 138
  • [25] Performance optimization of transcritical CO2 refrigeration cycle with thermoelectric subcooler
    Sarkar, Jahar
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (02) : 121 - 128
  • [27] Dynamic model of a transcritical CO2 ejector expansion refrigeration system
    Zheng, Lixing
    Deng, Jianqiang
    He, Yang
    Jiang, Peixue
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 : 247 - 260
  • [28] Two-phase radial ejector for transcritical CO2 refrigeration
    Chandran Ramachandran, Jishnu
    Sadasivan, Sreeja
    Arumugam, Senthil Kumar
    Chen, Fei
    PHYSICS OF FLUIDS, 2024, 36 (12)
  • [29] EXPERIMENTAL COMPARISON OF THE PERFORMANCE OF A CO2 EJECTOR CYCLE FOR TRANSCRITICAL AND SUBCRITICAL OPERATION
    Lawrence, N.
    Elbel, S.
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 527 - 534
  • [30] Thermodynamic analysis and optimization of novel ejector-expansion TRCC (transcritical CO2) cascade refrigeration cycles (Novel transcritical CO2 cycle)
    Yari, Mortaza
    Mahmoudi, S. M. S.
    ENERGY, 2011, 36 (12) : 6839 - 6850